Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38892961

RESUMO

Objectives: A growing body of evidence highlights the effects of air pollution on chronic and acute cardiovascular diseases, such as associations between PM10 and several cardiovascular events. However, evidence of the impact of fine air pollutants on the development and progression of peripheral arterial aneurysms is not available. Methods: Data were obtained from the multicenter PAA outcome registry POPART and the German Environment Agency. Means of the mean daily concentration of PM10, PM2.5, NO2, and O3 concentrations were calculated for 2, 10, and 3650 days prior to surgery for each patient. Additionally, weighted ten-year averages were analyzed. Correlation was assessed by calculating Pearson correlation coefficients, and regression analyses were conducted as multiple linear or multiple logistic regression, depending on the dependent variable. Results: For 1193 patients from the POPART registry, paired air pollution data were available. Most patients were male (95.6%) and received open surgical repair (89.9%). On a regional level, the arithmetic means of the daily means of PM10 between 2000 and 2022 were neither associated with average diameters nor runoff vessels. Negative correlations for mean PAA diameter and mean NO2, as well as a positive correlation with mean O3, were found; however, they were not statistically significant. On patient level, no evidence for an association of mean PM10 exposure over ten years prior to inclusion in the registry and PAA diameter or the number of runoff vessels was found. Weighted PM10, NO2, and O3 exposure over ten years also did not result in significant associations with aneurysm diameter or runoff vessels. Short-term air pollutant concentrations were not associated with symptomatic PAAs or with perioperative complications. Conclusions: We found no indication that long-term air pollutant concentrations are associated with PAA size or severity, neither on a regional nor individual level. Additionally, short-term air pollution showed no association with clinical presentation or treatment outcomes.

2.
J Am Heart Assoc ; 13(12): e034429, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38879461

RESUMO

BACKGROUND: Popliteal artery aneurysms (PAAs) are the most common peripheral aneurysm. However, due to its rarity, the cumulative body of evidence regarding patient patterns, treatment strategies, and perioperative outcomes is limited. This analysis aims to investigate distinct phenotypical patient profiles and associated treatment and outcomes in patients with a PAA by performing an unsupervised clustering analysis of the POPART (Practice of Popliteal Artery Aneurysm Repair and Therapy) registry. METHODS AND RESULTS: A cluster analysis (using k-means clustering) was performed on data obtained from the multicenter POPART registry (42 centers from Germany and Luxembourg). Sensitivity analyses were conducted to explore validity and stability. Using 2 clusters, patients were primarily separated by the absence or presence of clinical symptoms. Within the cluster of symptomatic patients, the main difference between patients with acute limb ischemia presentation and nonemergency symptomatic patients was PAA diameter. When using 6 clusters, patients were primarily grouped by comorbidities, with patients with acute limb ischemia forming a separate cluster. Despite markedly different risk profiles, perioperative complication rates appeared to be positively associated with the proportion of emergency patients. However, clusters with a higher proportion of patients having any symptoms before treatment experienced a lower rate of perioperative complications. CONCLUSIONS: The conducted analyses revealed both an insight to the public health reality of PAA care as well as patients with PAA at elevated risk for adverse outcomes. This analysis suggests that the preoperative clinic is a far more crucial adjunct to the patient's preoperative risk assessment than the patient's epidemiological profile by itself.


Assuntos
Aneurisma , Artéria Poplítea , Sistema de Registros , Humanos , Artéria Poplítea/cirurgia , Aneurisma/epidemiologia , Aneurisma/cirurgia , Aneurisma/diagnóstico , Masculino , Feminino , Idoso , Análise por Conglomerados , Alemanha/epidemiologia , Fatores de Risco , Pessoa de Meia-Idade , Resultado do Tratamento , Medição de Risco , Idoso de 80 Anos ou mais , Procedimentos Endovasculares , Complicações Pós-Operatórias/epidemiologia , Aneurisma da Artéria Poplítea
3.
Diagnostics (Basel) ; 14(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38732344

RESUMO

OBJECTIVES: Surveillance after endovascular aortic repair (EVAR) and fenestrated EVAR (FEVAR) is mainly directed by one-size-fits-all approaches instead of personalized decision making, even though treatment strategies and often endografts themselves are tailor-made to adjust for individual patients. We propose a modular imaging algorithm that escalates surveillance imaging based on invasiveness and need. MATERIALS AND METHODS: In this retrospective observational study of single-center data, results of a modular imaging algorithm were analyzed. The algorithm is characterized by initiating the examination with standard B-mode then transitioning to Duplex ultrasound, B-Flow, and CEUS. Additional CT(A) studies are conducted where required. The study population included both patients receiving EVAR or FEVAR. A comparative analysis was conducted regarding endoleak detection. RESULTS: The study population included 28 patients receiving EVAR and 40 patients receiving FEVAR. They accounted for 101 follow-up visits, which led to 431 distinct imaging studies. CEUS has the highest endoleak detection rate, followed by CTA and B-Flow. Duplex ultrasound and B-Flow resulted in 0 and 1 false positive cases, respectively, considering CEUS the reference standard. In a select group of six patients, CEUS was omitted after endoleaks were displayed by Duplex ultrasound or B-Flow, leading to a successful type II coiling and no aneurysm-related adverse events. CONCLUSIONS: The proposed modular algorithm showed great potential to incorporate principles of personalized medicine in surveillance after endovascular aortic treatment. Since Duplex ultrasound and B-Flow rarely cause false positive endoleaks, more resource-intensive and invasive imaging studies such as CEUS and CTA can be omitted after positive identification.

4.
Dermatopathology (Basel) ; 11(1): 62-78, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38390849

RESUMO

Ulcerations of the lower extremities are a frequently encountered problem in clinical practice and are of significant interest in public health due to the high prevalence of underlying pathologies, including chronic venous disease, diabetes and peripheral arterial occlusive disease. However, leg ulcers can also present as signs and symptoms of various rare diseases and even as an adverse reaction to drugs. In such cases, correct diagnosis ultimately relies on histopathological examination. Apart from the macroscopic presentation, patient history and anatomic location, which are sometimes indicative, most ulcers have very distinct histopathological features. These features are found in different layers of the skin or even associated vessels. In this narrative review, we discuss and highlight the histopathological differences of several types of leg ulcers that can contribute to efficient and accurate diagnosis.

5.
Front Immunol ; 14: 1179036, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37731514

RESUMO

Introduction: Antibody mediated rejection (ABMR) is a major factor limiting outcome after organ transplantation. Anti-HLA donor-specific antibodies (DSA) of the IgG isotype are mainly responsible for ABMR. Recently DSA of the IgE isotype were demonstrated in murine models as well as in a small cohort of sensitized transplant recipients. In the present study, we aimed to determine the frequency of pre-existing and de novo anti-HLA IgE antibodies in a cohort of 105 solid organ transplant recipients. Methods: We prospectively measured anti-HLA IgE antibodies in a cohort of kidney (n=60), liver, heart and lung (n=15 each) transplant recipients before and within one-year after transplantation, employing a single-antigen bead assay for HLA class I and class II antigens. Functional activity of anti-HLA IgE antibodies was assessed by an in vitro mediator release assay. Antibodies of the IgG1-4 subclasses and Th1 and Th2 cytokines were measured in anti-HLA IgE positive patients. Results: Pre-existing anti-HLA IgE antibodies were detected in 10% of renal recipients (including 3.3% IgE-DSA) and in 4.4% of non-renal solid organ transplant recipients (heart, liver and lung cohort). Anti-HLA IgE occurred only in patients that were positive for anti-HLA IgG, and most IgE positive patients had had a previous transplant. Only a small fraction of patients developed de novo anti-HLA IgE antibodies (1.7% of kidney recipients and 4.4% of non-renal recipients), whereas no de novo IgE-DSA was detected. IgG subclass antibodies showed a distinct pattern in patients who were positive for anti-HLA IgE. Moreover, patients with anti-HLA IgE showed elevated Th2 and also Th1 cytokine levels. Serum from IgE positive recipients led to degranulation of basophils in vitro, demonstrating functionality of anti-HLA IgE. Discussion: These data demonstrate that anti-HLA IgE antibodies occur at low frequency in kidney, liver, heart and lung transplant recipients. Anti-HLA IgE development is associated with sensitization at the IgG level, in particular through previous transplants and distinct IgG subclasses. Taken together, HLA specific IgE sensitization is a new phenomenon in solid organ transplant recipients whose potential relevance for allograft injury requires further investigation.


Assuntos
Transplante de Coração , Fígado , Humanos , Animais , Camundongos , Estudos Prospectivos , Rim , Imunossupressores , Soro Antilinfocitário , Imunoglobulina G , Pulmão , Imunoglobulina E
6.
J Clin Med ; 12(11)2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37298053

RESUMO

INTRODUCTION: Fenestrated endovascular aortic repair (FEVAR) has become a popular custom-made treatment option for juxtarenal and pararenal aneurysms. It has been previously investigated whether octogenarians as a distinct subgroup are at increased risk for adverse outcomes after FEVAR. With diverging results and an inconclusive understanding of age as a risk factor in general, an analysis of the historical data of a single center was conducted to add to the available body of evidence and further investigate the effect of age as a continuous risk factor. METHODS: A retrospective data analysis of a prospectively maintained single-center database of all patients who underwent FEVAR at a single department of vascular surgery was performed. The main endpoint was post-operative survival. In addition to association analyses, potential confounders such as co-morbidities, complication rates, or aneurysm diameter were examined. In terms of sensitivity analyses, logistic regression models were created for the dependent variables of interest. RESULTS: During the observation period from April 2013 to November 2020, 40 patients over the age of 80 and 191 patients under the age of 80 were treated by FEVAR. The 30-day survival showed no significant difference between the groups (95.1% in octogenarians and 94.3% in patients under 80 years of age). The sensitivity analyses conducted also showed no difference between the two groups, and complication and technical success rates were comparable. The aneurysm diameter was 67 ± 13 mm in the study group and 61 ± 15 mm in those under 80 years of age. Additionally, the sensitivity analyses showed that age as a continuous variable exhibits no effect on the outcomes of interest. DISCUSSION: In the present study, age was not associated with adverse peri-operative outcomes after FEVAR, including mortality, lower technical success rates, complications, or length of hospital stay. Essentially, the most highly associated factor with hospital and ICU length of stay was time spent in surgery. However, octogenarians had a significantly larger aortic diameter at the time of treatment, which might indicate the potential introduction of bias by pre-interventional patient selection. Nevertheless, the usefulness of research on octogenarians as a distinct subgroup might be questionable regarding the scalability of results, and future studies might focus on age as a continuous risk factor instead.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...