1.
Minerva Anestesiol ; 89(3): 131-137, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36287389

RESUMO

BACKGROUND: By preventing hypoxia and hypercapnia, advanced airway management can save lives among patients with traumatic brain injury. During endotracheal intubation (ETI), tracheal stimulation causes an increase in intracranial pressure (ICP), which may impair brain perfusion. It has been suggested that intravenous lidocaine might attenuate this ICP response. We hypothesized that adding lidocaine to the standard induction medication for general anesthesia might reduce the ICP response to ETI. Here, we measured the optical nerve sheath diameter (ONSD) as a correlate of ICP and evaluated the effect of intravenous lidocaine on ONSD during and after ETI in patients undergoing anesthesia. METHODS: This double-blinded, randomized placebo-controlled trial included 60 patients with American Society of Anesthesiologists I or II physical status that were scheduled for elective surgery under general anesthesia. In addition to the standard anesthesia medication, 30 subjects received 1.5 mg/kg 1% lidocaine (0.15 mL/kg, ONSD lidocaine) and 30 received 0.15 mL/kg 0.9% NaCl (ONSD placebo). ONSDs were measured with ultrasound on the left eye, before (T0), during (T1), and 4 times after ETI (T2-5 at 5-min intervals). RESULTS: Compared to placebo, lidocaine did not significantly affect the baseline ONSD after anesthesia induction measured at T0. During ETI, the ONSD lidocaine was significantly smaller (ß=-0.24 mm P=0.022) than the ONSD placebo. At T4 and T5, the ONSD placebo increased steadily, up to 20 min after ETI, but the ONSD lidocaine tended to return to baseline levels. CONCLUSIONS: We found that the ONSD was distended during and after ETI in anesthetized patients, and intravenous lidocaine attenuated this effect.


Assuntos
Anestésicos , Hipertensão Intracraniana , Humanos , Lidocaína/farmacologia , Lidocaína/uso terapêutico , Pressão Intracraniana/fisiologia , Anestésicos/farmacologia , Anestesia Geral/efeitos adversos , Intubação Intratraqueal/efeitos adversos , Hipertensão Intracraniana/terapia
2.
J Emerg Med ; 63(2): 200-211, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-36038435

RESUMO

BACKGROUND: Ultrasonographic measurements of the diameter of the sheath of the optic nerve can be used to assess intracranial pressure indirectly. These measurements come with measurement error. OBJECTIVE: Our aim was to estimate observer's measurement error as a determinant of ultrasonographic measurement variability of the optic nerve sheath diameter. METHODS: A systematic search of the literature was conducted in Embase, Medline, Web of Science, the Cochrane Central Register of Trials, and the first 200 articles of Google Scholar up to April 19, 2021. Inclusion criteria were the following: healthy adults, B-mode ultrasonography, and measurements 3 mm behind the retina. Studies were excluded if standard error of measurement could not be calculated. Nine studies featuring 389 participants (median 40; range 15-100) and 22 observers (median 2; range 1-4) were included. Standard error of measurement and minimal detectable differences were calculated to quantify observer variability. Quality and risk of bias were assessed with the Guidelines for Reporting Reliability and Agreement Studies. RESULTS: The standard error of measurement of the intra- and interobserver variability had a range of 0.10-0.41 mm and 0.14-0.42 mm, respectively. Minimal detectable difference of a single observer was 0.28-1.1 mm. Minimal detectable difference of multiple observers (range 2-4) was 0.40-1.1 mm. Quality assessment showed room for methodological improvement of included studies. CONCLUSIONS: The standard errors of measurement and minimal detectable differences of ultrasonographic measurements of the optic nerve sheath diameter found in this review with healthy participants indicate caution should be urged when interpreting results acquired with this measurement method in clinical context.


Assuntos
Pressão Intracraniana , Nervo Óptico , Adulto , Humanos , Variações Dependentes do Observador , Nervo Óptico/diagnóstico por imagem , Reprodutibilidade dos Testes , Ultrassonografia/métodos