Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Am ; 80(10): 1507-14, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9801219

RESUMO

We examined the effects of multiple-strand suture techniques on the tensile properties of flexor digitorum profundus tendon-to-bone repairs in a human cadaver finger model. Forty-four fingers were obtained from the cadavera of fifteen donors who had been an average of seventy-four years old (range, fifty-four to eighty-nine years old) at the time of death. Four or eight-strand proximal grasping sutures were secured to the distal phalanx of each finger with use of either a suture anchor or a dorsally placed button. There were four subgroups of eleven fingers each. We found that repairs performed with use of a dorsally placed button had greater yield force, ultimate force, and rigidity than those performed with use of an anchor and that repairs performed with eight strands had greater ultimate force than those performed with four strands. These differences were significant (p < 0.05). We could detect no differences among the four types of repairs with regard to the amount of relative tendon-bone elongation at twenty newtons of force. The repairs performed with eight strands and a dorsally placed button had an average yield force (and 95 per cent confidence interval) of 50.0 +/- 14.1 newtons, an average ultimate force of 68.5 +/- 14.6 newtons, an average rigidity of 744 +/- 327 newton/(millimeter/millimeter), and an average tendon-bone elongation of 3.4 +/- 0.7 millimeters at twenty newtons of force. Multiple-comparison testing showed that the eight-strand repairs performed with a dorsally placed button had greater ultimate force than the other three types of repairs as well as greater yield force and rigidity than the four and eight-strand repairs performed with a suture anchor.


Assuntos
Dedos/cirurgia , Técnicas de Sutura , Tendões/cirurgia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Cadáver , Intervalos de Confiança , Elasticidade , Falha de Equipamento , Humanos , Pessoa de Meia-Idade , Estresse Mecânico , Técnicas de Sutura/instrumentação , Suturas , Tendões/fisiologia , Resistência à Tração
2.
Am J Respir Crit Care Med ; 158(3): 742-8, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9730999

RESUMO

We investigated the effect changes in end-expiratory lung volume (EEVL) had on the response to progressive hypercapnia (CO2-response curve) in eight open-chest, anesthetized dogs, in order to clarify the role that vagal lung mechanoreceptors have in altered respiratory drive during permissive hypercapnia. The dogs were ventilated using a positive-pressure ventilator driven by phrenic neural activity. Systemic arterial CO2 tension (PaCO2) was elevated by increasing the fraction of CO2 delivered to the ventilator. EEVL was altered from approximated functional residual capacity ("FRC") to 1.5 and 0.5 "FRC" by changing positive end-expiratory pressure. Although the tidal volume (VT)-PaCO2 and inspiratory time (TI)-PaCO2 relationships were not affected, decreasing EEVL from 1.5 "FRC" to "FRC" and then to 0.5 "FRC" caused a significant (p < 0.01) upward shift in the CO2-response curves for minute ventilation (V I) and frequency (f ), and a significant (p < 0.01) downward shift in the CO2- response curve for expiratory time (TE). We conclude that these shifts were explained by a decrease in the inhibitory activity of slowly adapting pulmonary stretch receptors (PSRs) as EEVL was lowered. In addition, increases in EEVL from 0.5 "FRC" to 1.5 "FRC" caused a significant (p < 0.05) increase in the apneic threshold, which we attribute to an inhibitory effect on central drive caused by increased PSR activity.


Assuntos
Capacidade Residual Funcional/fisiologia , Hipercapnia/fisiopatologia , Pulmão/fisiopatologia , Respiração com Pressão Positiva , Adaptação Fisiológica , Animais , Apneia/fisiopatologia , Dióxido de Carbono/administração & dosagem , Dióxido de Carbono/sangue , Cães , Volume de Reserva Expiratória/fisiologia , Inalação/fisiologia , Pulmão/inervação , Mecanorreceptores/fisiologia , Receptores Pulmonares de Alongamento/fisiologia , Tempo de Reação , Análise de Regressão , Respiração/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Fatores de Tempo , Nervo Vago/fisiopatologia
3.
J Bone Joint Surg Br ; 80(3): 493-8, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9619944

RESUMO

To establish the value of median nerve compression with wrist flexion as a provocative test for carpal tunnel syndrome (CTS), we performed a prospective study of 64 patients (95 hands) with CTS confirmed by electrodiagnostic studies and 50 normal subjects (96 hands). We recorded results for the common provocative tests (Tinel's percussion test, Phalen's wrist flexion test and the carpal compression test) and the new test which combines wrist flexion with median nerve compression. Using a receiver operator characteristic curve (ROC) technique, we found that the optimal cut-off time for the wrist-flexion and median-nerve compression test was 20 s, giving a sensitivity of 82% and a specificity of 99%. These results were significantly better than for Phalen's wrist flexion test (61% and 83%, respectively) and for the sensitivity of Tinel's test (74%). The positive predictive values of the wrist flexion and median-nerve compression test, which is more important clinically, were 99%, 95% and 81% at population prevalences of 50%, 20% and 5%, respectively. These were significantly better than those of the three other provocative tests at each prevalence. Electrodiagnostic studies have significant false-positive and false-negative rates in CTS, and therefore provocative tests remain important in its diagnosis. We have shown that wrist flexion combined with the median-nerve compression test at 20 s, is significantly better than the other methods, and may thus be clinically useful.


Assuntos
Síndrome do Túnel Carpal/diagnóstico , Nervo Mediano/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Articulação do Punho/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodiagnóstico , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Percussão , Valor Preditivo dos Testes , Pressão , Prevalência , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Fatores de Tempo
4.
J Bone Joint Surg Am ; 80(4): 492-501, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9563378

RESUMO

The purpose of this study was to determine the relationship between the ulnar nerve and the cubital tunnel during flexion of the elbow with use of magnetic resonance imaging and measurements of intraneural and extraneural interstitial pressure. Twenty specimens from human cadavera were studied with the elbow in positions of incremental flexion. With use of magnetic resonance imaging, cross-sectional images were made at each of three anatomical regions of the cubital tunnel: the medial epicondyle, deep to the cubital tunnel aponeurosis, and deep to the flexor carpi ulnaris muscle. The cross-sectional areas of the cubital tunnel and the ulnar nerve were calculated and compared for different positions of elbow flexion. Interstitial pressures were measured with use of ultrasonographic imaging to allow a minimally invasive method of placement of the pressure catheter, both within the cubital tunnel and four centimeters proximal to it, at 10-degree increments from 0 to 130 degrees of elbow flexion. As the elbow was moved from full extension to 135 degrees of flexion, the mean cross-sectional area of the three regions of the cubital tunnel decreased by 30, 39, and 41 per cent and the mean area of the ulnar nerve decreased by 33, 50, and 34 per cent. These changes were significant in all three regions of the cubital tunnel (p < 0.05). The greatest changes occurred in the region beneath the aponeurosis of the cubital tunnel with the elbow at 135 degrees of flexion. The mean intraneural pressure within the cubital tunnel was significantly higher than the mean extraneural pressure when the elbow was flexed 90, 100, 110, and 130 degrees (p < 0.05). With the elbow flexed 130 degrees, the mean intraneural pressure was 45 per cent higher than the mean extraneural pressure (p < 0.001). Similarly, with the elbow flexed 120 degrees or more, the mean intraneural pressure four centimeters proximal to the cubital tunnel was significantly higher than the mean extraneural pressure (p < 0.01). Relative to their lowest values, intraneural pressure increased at smaller angles of flexion than did extraneural pressure, both within the cubital tunnel and proximal to it. With the numbers available, we could not detect any significant difference in intraneural pressure measured, either at the level of the cubital tunnel or four centimeters proximal to it, after release of the aponeurotic roof of the cubital tunnel.


Assuntos
Articulação do Cotovelo/fisiologia , Nervo Ulnar/anatomia & histologia , Articulação do Punho/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Humanos , Técnicas In Vitro , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Movimento , Pressão , Nervo Ulnar/diagnóstico por imagem , Ultrassonografia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiologia
5.
J Hand Surg Am ; 23(1): 120-6, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9523965

RESUMO

Avulsions or distal transsections of the flexor digitorum profundus tendon are typically repaired by direct suture of tendon to the distal phalanx. The tensile properties of tendon-tobone repairs performed in cadaver fingers using 3 common suture patterns, the Bunnell, the Kessler, and the Kleinert techniques, were compared; 3-0 Prolene (monofilament) suture was used. Repairs done using the Kessler pattern had an average yield force of 30 N, compared to 39 N for the Bunnell and Kleinert patterns. Although these average yield forces were greater than that required for active digital flexion, considerable elongation (average, 8 mm) was measured at a force of 20 N. Data indicated that the safety factor achieved with these repair methods is lower than that achieved with modern tendon-to-tendon repair methods. The authors conclude that the common tendon-to-bone repair techniques are insufficient to withstand the higher forces associated with controlled passive and active motion rehabilitation methods that are currently advocated.


Assuntos
Dedos/cirurgia , Técnicas de Sutura , Tendões/cirurgia , Idoso , Cadáver , Articulações dos Dedos/fisiologia , Articulações dos Dedos/cirurgia , Dedos/fisiologia , Humanos , Polipropilenos , Distribuição Aleatória , Suturas , Tendões/fisiologia , Resistência à Tração
6.
J Appl Physiol (1985) ; 71(5): 1795-800, 1991 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1761476

RESUMO

We examined the contribution of afferent vagal A- and C-fibers on abdominal expiratory muscle activity (EMA). In seven spontaneously breathing supine dogs anesthetized with alpha-chloralose we recorded the electromyogram of the external oblique muscle at various vagal temperatures before and after the induction of a pneumothorax. When myelinated fibers were blocked selectively by cooling the vagus nerves to 7 degrees C, EMA decreased to 40% of control (EMA at 39 degrees C). With further cooling to 0 degrees C, removing afferent vagal C-fiber activity, EMA returned to 72% of control. On rewarming the vagus nerves to 39 degrees C, we then induced a pneumothorax (27 ml/kg) that eliminated the EMA in all the dogs studied. Cooling the vagus nerves to 7 degrees C, during the pneumothorax, produced a slight though not significant increase in EMA. However, further cooling of the vagus nerves to 0 degrees C caused the EMA to return vigorously to 116% of control. In three dogs, intravenous infusion of a constant incrementally increasing dose of capsaicin, a C-fiber stimulant, decreased EMA in proportion to the dose delivered. These results suggest that EMA is modulated by a balance between excitatory vagal A-fiber activity, most likely from slowly adapting pulmonary stretch receptors, and inhibitory C-fiber activity, most likely from lung C-fibers.


Assuntos
Músculos Respiratórios/inervação , Nervo Vago/fisiologia , Abdome , Vias Aferentes/fisiologia , Animais , Capsaicina/farmacologia , Temperatura Baixa , Cães , Eletromiografia , Fibras Nervosas/fisiologia , Pneumotórax/fisiopatologia , Reflexo/fisiologia , Músculos Respiratórios/efeitos dos fármacos , Músculos Respiratórios/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...