Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37603369

RESUMO

BACKGROUND: In the ongoing development of bioresorbable implants, there has been a particular focus on magnesium (Mg)-based alloys. Several Mg alloys have shown promising properties, including a lean, bioresorbable magnesium-zinc-calcium (Mg-Zn-Ca) alloy designated as ZX00. To our knowledge, this is the first clinically tested Mg-based alloy free from rare-earth elements or other elements. Its use in medial malleolar fractures has allowed for bone healing without requiring surgical removal. It is thus of interest to assess the resorption behavior of this novel bioresorbable implant. QUESTIONS/PURPOSES: (1) What is the behavior of implanted Mg-alloy (ZX00) screws in terms of resorption (implant volume, implant surface, and gas volume) and bone response (histologic evaluation) in a sheep model after 13 months and 25 months? (2) What are the radiographic changes and clinical outcomes, including patient-reported outcome measures, at a mean of 2.5 years after Mg-alloy (ZX00) screw fixation in patients with medial malleolar fractures? METHODS: A sheep model was used to assess 18 Mg-alloy (ZX00) different-length screws (29 mm, 24 mm, and 16 mm) implanted in the tibiae and compared with six titanium-alloy screws. Micro-CT was performed at 13 and 25 months to quantify the implant volume, implant surface, and gas volume at the implant sites, as well as histology at both timepoints. Between July 2018 and October 2019, we treated 20 patients with ZX00 screws for medial malleolar fractures in a first-in-humans study. We considered isolated, bimalleolar, or trimalleolar fractures potentially eligible. Thus, 20 patients were eligible for follow-up. However, 5% (one patient) of patients were excluded from the analysis because of an unplanned surgery for a pre-existing osteochondral lesion of the talus performed 17 months after ZX00 implantation. Additionally, another 5% (one patient) of patients were lost before reaching the minimum study follow-up period. Our required minimum follow-up period was 18 months to ensure sufficient time to observe the outcomes of interest. At this timepoint, 10% (two patients) of patients were either missing or lost to follow-up. The follow-up time was a mean of 2.5 ± 0.6 years and a median of 2.4 years (range 18 to 43 months). RESULTS: In this sheep model, after 13 months, the 29-mm screws (initial volume: 198 ± 1 mm3) degraded by 41% (116 ± 6 mm3, mean difference 82 [95% CI 71 to 92]; p < 0.001), and after 25 months by 65% (69 ± 7 mm3, mean difference 130 [95% CI 117 to 142]; p < 0.001). After 13 months, the 24-mm screws (initial volume: 174 ± 0.2 mm3) degraded by 51% (86 ± 21 mm3, mean difference 88 [95% CI 52 to 123]; p = 0.004), and after 25 months by 72% (49 ± 25 mm3, mean difference 125 [95% CI 83 to 167]; p = 0.003). After 13 months, the 16-mm screws (initial volume: 112 ± 5 mm3) degraded by 57% (49 ± 8 mm3, mean difference 63 [95% CI 50 to 76]; p < 0.001), and after 25 months by 61% (45 ± 10 mm3, mean difference 67 [95% CI 52 to 82]; p < 0.001). Histologic evaluation qualitatively showed ongoing resorption with new bone formation closely connected to the resorbing screw without an inflammatory reaction. In patients treated with Mg-alloy screws after a mean of 2.5 years, the implants were radiographically not visible in 17 of 18 patients and the bone had homogenous texture in 15 of 18 patients. No clinical or patient-reported complications were observed. CONCLUSION: In this sheep model, Mg-alloy (ZX00) screws showed a resorption to one-third of the original volume after 25 months, without eliciting adverse immunologic reactions, supporting biocompatibility during this period. Mg-alloy (ZX00) implants were not detectable on radiographs after a mean of 2.5 years, suggesting full resorption, but further studies are needed to assess environmental changes regarding bone quality at the implantation site after implant resorption. CLINICAL RELEVANCE: The study demonstrated successful healing of medial malleolar fractures using bioresorbable Mg-alloy screws without clinical complications or revision surgery, resulting in pain-free ankle function after 2.5 years. Future prospective studies with larger samples and extended follow-up periods are necessary to comprehensively assess the long-term effectiveness and safety of ZX00 screws, including an exploration of limitations when there is altered bone integrity, such as in those with osteoporosis. Additional use of advanced imaging techniques, such as high-resolution CT, can enhance evaluation accuracy.

2.
Wien Klin Wochenschr ; 133(5-6): 209-215, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32617706

RESUMO

BACKGROUND: First tarsometatarsal joint (TMT-1) hypermobility might cause hallux valgus deformity (HV), and recurrence following surgical correction. Anatomic findings, indicating tibialis anterior tendon (TAT) involvement in TMT­1 stabilization, led to the development of cross-glide test allowing clinical TMT­1 stability testing. Cross-glide test function was evaluated in anatomical specimens and in the clinical setting, compared to simulated weight-bearing computer tomography (CT) analysis. METHODS: Cross-glide test was evaluated in 6 healthy lower leg specimens before and after TAT transection. Clinical testing was performed prospectively in 36 feet (6 controls, 21 HV, 9 recurrent HV); consecutive weight-bearing CT analysis was performed. Results from clinical testing were compared to CT analysis. RESULTS: TMT­1 instability significantly increased in anatomic specimens following TAT transection (p = 0.009). In the clinical setting, all healthy feet were cross-glide test negative, 62% of HV cases and all recurrent HV feet were positive. In the CT analysis- Compared to controls the HV cases revealed significantly increased MT­1 internal rotation (p = 0.003) and decreased dorsal angle (p = 0.002), considered as collapsing forefoot signs; HV recurrent cases revealed similar results. Positive cross-glide tested cases revealed increased MT­1 internal rotation values (p < 0.001) and dorsal angle values (p < 0.001) in CT analysis. Strikingly, cross-glide test positive HV cases revealed significantly increased internal TMT­1 rotation (p = 0.043) in CT analysis, and HV and IMT (intermetatarsal) angle were significantly higher (p = 0.005, p = 0.006). 15 HV recurrence cases, treated with TMT­1 arthrodesis, revealed no recurrence during follow-up. CONCLUSION: Cross-glide test allows reliable clinical TMT­1 instability testing, via TAT tension, and is less laborious than CT analysis. We recommend TMT­1 arthrodesis in cases with instability in clinical testing, to avoid HV recurrence.


Assuntos
Hallux Valgus , Instabilidade Articular , Artrodese , Hallux Valgus/diagnóstico por imagem , Hallux Valgus/cirurgia , Humanos , Instabilidade Articular/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
Innov Surg Sci ; 3(2): 119-125, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31579775

RESUMO

Pediatric osteosynthesis has developed over the last 20 years, thereby reducing medical and economic burden, including long and expensive hospitalization. Currently, conventional and rigid alloying systems such as titanium are used for stabilization of bone fractures in children. In many cases, implants must be removed, as otherwise growth would be impeded. Biodegradable implant materials exhibit beneficial properties and would make a second removal surgery unnecessary. In the following article, we will give an overview of implant materials that are currently used in pediatric traumatology with a focus on Mg-based implants. Furthermore, we will discuss current scientific knowledge on resorbable implants, including results from pre-clinics and clinics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...