Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 13(10): e0202716, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30346953

RESUMO

Prosthetic elevated vacuum is a suspension method used to reduce daily volume changes of the residual limb. Evaluation of the effectiveness of these systems is limited due to a lack of correlation to actual socket air pressure, particularly during unconstrained movements. This may explain some of the variability in functional outcomes reported in the literature. Our objective was to develop a light-weight portable socket measurement system to quantify internal socket air pressure, temperature, and acceleration; and to present preliminary results from implementation with three transtibial prosthesis users with mechanical elevated vacuum pumps. Participants completed five functional tasks with and without the vacuum pumps actively connected, including the 2-Minute Walk test, 5-Times Sit-to-Stand test, 4-Square Step test, L-Test, and Figure-8 test. Results demonstrated different gait profiles and pressure ranges for each user. Two of the participants demonstrated substantially lower air pressure (higher vacuum) over time while the pump was active compared to inactive. The minimum air pressure measured for all participants was -34.6 ± 7.7 kPa. One participant did not show substantial changes in pressure over time for either pump condition. Functional task performance was not significantly different between pump conditions. Correlation with accelerometer readings indicated peak positive pressures occurred just following initial contact of the foot in early stance, and the most negative pressures (highest vacuum) were observed throughout swing. This study has demonstrated the use of a portable data logging tool that may serve the clinical and research communities to quantify the operation of elevated vacuum systems, and better understand the variability of mechanical pump operation and overall system performance.


Assuntos
Membros Artificiais , Tíbia/fisiopatologia , Caminhada/fisiologia , Adolescente , Adulto , Idoso , Pressão do Ar , Cotos de Amputação/fisiopatologia , Amputados , Feminino , Marcha/fisiologia , Análise da Marcha , Humanos , Articulações/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/métodos , Ajuste de Prótese/métodos , Inquéritos e Questionários , Vácuo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...