Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Korean Med Sci ; 38(47): e408, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38050917

RESUMO

The coronavirus disease 2019 pandemic has brought significant changes to infectious disease management globally. This study explored changes in clinical microbiological testing trends and their implications for infectious disease incidence and medical utilization during the pandemic. We collected nationwide claims for monthly clinical microbiology tests from January 2018 to March 2022 using the National Health Insurance Service database. Seasonal autoregressive integrated moving average models were employed to make predictions for each disease based on the baseline period (January 2018 to January 2020). The results showed a significant decrease in general bacterial and fungal cultures, respiratory infectious disease-related, and inflammatory markers, while the representatives of tests for vector-borne diseases, healthcare-associated infections, and chronic viral infections remained stable. The study highlights the potential of clinical microbiological testing trends as an additional surveillance tool and offers implications for future infectious disease management and surveillance strategies in pandemic settings.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , SARS-CoV-2 , Teste para COVID-19 , República da Coreia/epidemiologia
2.
Ann Lab Med ; 43(5): 443-450, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37080745

RESUMO

Background: Early diagnosis and treatment are important for a good prognosis of bloodstream infections. The European Committee on Antimicrobial Susceptibility Testing (EUCAST) recommends rapid antimicrobial susceptibility testing (RAST) based on the disk diffusion methodology for 4, 6, and 8 hours of incubation. We evaluated EUCAST-RAST of Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus from positive blood culture bottles. Methods: Twenty strains of E. coli, K. pneumoniae, and S. aureus were tested using EUCAST-RAST. Ten antimicrobial agents against E. coli and K. pneumoniae and four agents against S. aureus were tested. The diameter of the inhibition zone (mm) was compared with the minimal inhibitory concentration (µg/mL) obtained using the Sensititre AST system (TREK Diagnostic Systems, East Grinstead, UK). Results: For E. coli, the percentage of total categorical agreement (CA) was 69.5% at 4 hours, and 87% at 8 hours. For K. pneumoniae, the total CA was 89% at 4 hours, and 95.5% at 6 hours. For S. aureus, the total CA was 100% after 4 hours. Discrepancies were observed mainly for E. coli with ß-lactam antimicrobial agents, and the numbers of errors decreased over time. Conclusions: EUCAST-RAST for K. pneumoniae and S. aureus met the United States Food and Drug Administration criteria at 6 and 4 hours, respectively, whereas that for E. coli did not meet the criteria for up to 8 hours. RAST can shorten the turn-around testing time by more than one day; therefore, if applied accurately according to laboratory conditions, antimicrobial agent results can be reported faster.


Assuntos
Anti-Infecciosos , Infecções Estafilocócicas , Humanos , Staphylococcus aureus , Escherichia coli , Antibacterianos/farmacologia , Klebsiella pneumoniae , Hemocultura , Testes de Sensibilidade Microbiana
4.
Genes (Basel) ; 14(1)2023 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-36672974

RESUMO

Background: Due to the extreme infectivity of SARS-CoV-2, sample-to-answer SARS-CoV-2 reverse transcription (RT) polymerase chain reaction (PCR) assays are urgently needed in order to facilitate infectious disease surveillance and control. The purpose of this study was to evaluate three sample-to-answer SARS-CoV-2 RT-PCR assays­BioFire COVID-19 Test, BioFire RP 2.1, and Cepheid Xpert Xpress SARS-CoV-2­using clinical samples. Methods: A total of 77 leftover nasopharyngeal swab (NP) swabs (36 positives and 41 negatives) confirmed by reference SARS-CoV-2 RT real-time (q) PCR assay were collected. The clinical sample concordance, as specified by their respective emergency use authorizations (EUAs), in comparison to the reference SARS-CoV-2 RT-qPCR assay, was assessed. Results: The results showed that all three sample-to-answer SARS-CoV-2 RT-PCR assays provided perfectly concordant results consistent with the reference SARS-CoV-2 RT-qPCR assay. The BioFire COVID-19 Test exhibited the best turnaround time (TAT) compared to the other assays, regardless of the test results, using one-way analysis of variance followed by Scheffe's post hoc test (p < 0.001). The Xpert Xpress SARS-CoV-2 showed a shorter average TAT (mean ± standard deviation, 49.9 ± 3.1 min) in the positive samples compared to that (55.7 ± 2.5 min) of the negative samples. Conclusions: Our evaluation demonstrates that the BioFire COVID-19 Test, BioFire RP 2.1, and Cepheid Xpert Xpress SARS-CoV-2 assays compare favorably to the reference SARS-CoV-2 RT-qPCR assay, along with a 100% concordance in assay results for clinical samples and an acceptable analytical performance at their guaranteed limits of detection. The addition of a widely used simultaneous sample-to-answer SARS-CoV-2 RT-PCR assay will contribute to the number of medical laboratories able to test for COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Técnicas de Laboratório Clínico/métodos , Teste para COVID-19 , Nasofaringe , Sensibilidade e Especificidade
5.
Ann Lab Med ; 43(1): 38-44, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36045055

RESUMO

Background: Reference materials are essential for the quality assurance of molecular detection methods. We developed and characterized synthetic norovirus GI and GII RNA reference materials. Methods: Norovirus GI and GII RNA sequences including the ORF1-ORF2 junction region were designed based on 1,495 reported norovirus sequences and synthesized via plasmid preparation and in vitro transcription. The synthetic norovirus GI and GII RNAs were evaluated using six commercial norovirus detection kits used in Korea and subjected to homogeneity and stability analyses. A multicenter study involving five laboratories and using four commercial real-time PCR norovirus detection assays was conducted for synthetic norovirus RNA characterization and uncertainty measurements. Results: The synthetic norovirus GI and GII RNAs were positively detected using the six commercial norovirus detection kits and were homogeneous and stable for one year when stored at -20°C or -70°C. All data from the five laboratories were within a range of 1.0 log copies/µL difference for each RNA, and the overall mean concentrations for norovirus GI and GII RNAs were 7.90 log copies/µL and 6.96 log copies/µL, respectively. Conclusions: The synthetic norovirus GI and GII RNAs are adequate for quality control based on commercial molecular detection reagents for noroviruses with high sequence variability. The synthetic RNAs can be used as reference materials in norovirus molecular detection methods.


Assuntos
Infecções por Caliciviridae , Norovirus , Infecções por Caliciviridae/diagnóstico , Genótipo , Humanos , Norovirus/genética , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , República da Coreia
7.
Ann Lab Med ; 43(2): 137-144, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36281507

RESUMO

While the coronavirus disease 2019 pandemic is ongoing, monkeypox has been rapidly spreading in non-endemic countries since May 2022. Accurate and rapid laboratory tests are essential for identifying and controlling monkeypox. Korean Society for Laboratory Medicine and the Korea Disease Prevention and Control Agency have proposed guidelines for diagnosing monkeypox in clinical laboratories in Korea. These guidelines cover the type of tests, selection of specimens, collection of specimens, diagnostic methods, interpretation of test results, and biosafety. Molecular tests are recommended as confirmatory tests. Skin lesion specimens are recommended for testing in the symptomatic stage, and the collection of both blood and oropharyngeal swabs is recommended in the presymptomatic or prodromal stage.


Assuntos
COVID-19 , Mpox , Humanos , Mpox/diagnóstico , COVID-19/diagnóstico , Técnicas de Laboratório Clínico , Pandemias , República da Coreia
8.
Osong Public Health Res Perspect ; 13(5): 360-369, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36328240

RESUMO

OBJECTIVES: Despite the introduction of vaccines, treatments, and massive diagnostic testing, the evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has continued to overcome barriers that had slowed its previous spread. As the virus evolves towards increasing fitness, it is critical to continue monitoring the occurrence of new mutations that could evade human efforts to control them. METHODS: We performed whole-genome sequencing using Oxford Nanopore MinION sequencing on 58 SARS-CoV-2 isolates collected during the ongoing coronavirus disease 2019 pandemic at a tertiary hospital in South Korea and tracked the emergence of mutations responsible for massive spikes in South Korea. RESULTS: The differences among lineages were more pronounced in the spike gene, especially in the receptor-binding domain (RBD), than in other genes. Those RBD mutations could compromise neutralization by antibodies elicited by vaccination or previous infections. We also reported multiple incidences of Omicron variants carrying mutations that could impair the diagnostic sensitivity of reverse transcription-polymerase chain reaction-based testing. CONCLUSION: These results provide an understanding of the temporal changes of variants and mutations that have been circulating in South Korea and their potential impacts on antigenicity, therapeutics, and diagnostic escape of the virus. We also showed that the utilization of the nanopore sequencing platform and the ARTIC workf low can provide convenient and accurate SARS-CoV-2 genomic surveillance even at a single hospital.

10.
Ann Clin Lab Sci ; 52(3): 374-381, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35777794

RESUMO

OBJECTIVE: Exploration of biomarkers to predict the severity of COVID-19 is important to reduce mortality. Upon COVID-19 infection, neutrophil extracellular traps (NET) are formed, which leads to a cytokine storm and host damage. Hence, the extent of NET formation may reflect disease progression and predict mortality in COVID-19. METHODS: We measured 4 NET parameters - cell-free double stranded DNA (cell-free dsDNA), neutrophil elastase, citrullinated histone H3 (Cit-H3), and histone - DNA complex - in 188 COVID-19 patients and 20 healthy controls. Survivors (n=166) were hospitalized with or without oxygen supplementation, while non-survivors (n=22) expired during in-hospital treatment. RESULTS: Cell-free dsDNA was significantly elevated in non-survivors in comparison with survivors and controls. The survival rate of patients with high levels of cell-free dsDNA, neutrophil elastase, and Cit-H3 was significantly lower than that of patients with low levels. These three markers significantly correlated with inflammatory markers (absolute neutrophil count and C-reactive protein). CONCLUSION: Since the increase in NET parameters indicates the unfavourable course of COVID-19 infection, patients predisposed to poor outcome can be rapidly managed through risk stratification by using these NET parameters.


Assuntos
COVID-19 , Armadilhas Extracelulares , Biomarcadores/metabolismo , COVID-19/diagnóstico , Ácidos Nucleicos Livres/sangue , Ácidos Nucleicos Livres/metabolismo , Armadilhas Extracelulares/metabolismo , Histonas/sangue , Histonas/metabolismo , Humanos , Elastase de Leucócito/sangue , Elastase de Leucócito/metabolismo , Neutrófilos/metabolismo , Prognóstico
11.
Ann Lab Med ; 42(5): 507-514, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35470270

RESUMO

With the rapid spread of the coronavirus disease (COVID-19), the need for rapid testing and diagnosis and consequently, the demand for mobile laboratories have increased. Despite this need, there are no clear guidelines for the operation, maintenance, or quality control of mobile laboratories. We provide guidelines for the operation, management, and quality control of mobile laboratories, and specifically for the implementation and execution of COVID-19 molecular diagnostic testing. These practical guidelines are primarily based on expert opinions and a laboratory accreditation inspection checklist. The scope of these guidelines includes the facility, preoperative evaluation, PCR testing, internal and external quality control, sample handling, reporting, laboratory personnel, biosafety level, and laboratory safety management. These guidelines are useful for the maintenance and operation of mobile laboratories not only in normal circumstances but also during public health crises and emergencies.


Assuntos
COVID-19 , Laboratórios , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Técnicas de Diagnóstico Molecular , SARS-CoV-2/genética
12.
Ann Lab Med ; 42(4): 391-397, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35177559

RESUMO

Korean Society for Laboratory Medicine and the Korea Disease Prevention and Control Agency have announced guidelines for diagnosing coronavirus disease (COVID-19) in clinical laboratories in Korea. With the ongoing pandemic, we propose an update of the previous guidelines based on new scientific data. This update includes recommendations for tests that were not included in the previous guidelines, including the rapid molecular test, antigen test, antibody test, and self-collected specimens, and a revision of the previous recommendations. This update will aid clinical laboratories in performing laboratory tests for diagnosing COVID-19.


Assuntos
COVID-19 , Técnicas de Laboratório Clínico , Humanos , Pandemias , SARS-CoV-2 , Manejo de Espécimes
13.
J Korean Med Sci ; 37(5): e38, 2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35132844

RESUMO

BACKGROUND: The interest in Clostridioides difficile infection (CDI) has increased, and the choice of assays became wider since the first national survey in Korea on CDI diagnosis in 2015. We conducted a survey of the domestic CDI assays with more varied questions to understand the current situation in Korea. METHODS: In April 2018, about 50 questions on the current status of CDI assays and details on implementation and perceptions were written, and a survey questionnaire was administered to laboratory medicine specialists in 200 institutions. RESULTS: One-hundred and fifty institutions responded to the questionnaire, of which 90 (60.0%) including one commercial laboratory, performed CDI assays. The toxin AB enzyme immunoassay (toxin AB EIA), nucleic acid amplification test (NAAT), and C. difficile culture, glutamate dehydrogenase assay, alone or in combination with other assays, were used in 75 (84.3%), 52 (58.4%), 35 (36.0%), and 23 (25.8%), respectively, and 65 (73.0%) institutions performed a combination of two or more assays. The sensitivity of toxin AB EIA was more negatively perceived, and that on specificity was more positively perceived. The perception of sensitivity and specificity of NAAT was mostly positive. Perception on the algorithm test projected it as useful but in need of countermeasures. Sixty-three (73.3%) institutions responded that they performed surveillance on CDI. CONCLUSION: This study provides useful evidence on the current status of CDI laboratory diagnosis in Korea as well as on items that require improvement and is thought to aid in standardizing and improving the CDI laboratory diagnosis in Korea.


Assuntos
Técnicas de Laboratório Clínico/métodos , Clostridioides difficile/isolamento & purificação , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/epidemiologia , Inquéritos Epidemiológicos , Humanos , Vigilância da População , República da Coreia
14.
Biosens Bioelectron ; 196: 113689, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34688112

RESUMO

We herein describe rapid and accurate clinical testing for COVID-19 by nicking and extension chain reaction system-based amplification (NESBA), an ultrasensitive version of NASBA. The primers to identify SARS-CoV-2 viral RNA were designed to additionally contain the nicking recognition sequence at the 5'-end of conventional NASBA primers, which would enable nicking enzyme-aided exponential amplification of T7 RNA promoter-containing double-stranded DNA (T7DNA). As a consequence of this substantially enhanced amplification power, the NESBA technique was able to ultrasensitively detect SARS-CoV-2 genomic RNA (gRNA) down to 0.5 copies/µL (= 10 copies/reaction) for both envelope (E) and nucleocapsid (N) genes within 30 min under isothermal temperature (41 °C). When the NESBA was applied to test a large cohort of clinical samples (n = 98), the results fully agreed with those from qRT-PCR and showed the excellent accuracy by yielding 100% clinical sensitivity and specificity. By employing multiple molecular beacons with different fluorophore labels, the NESBA was further modulated to achieve multiplex molecular diagnostics, so that the E and N genes of SARS-CoV-2 gRNA were simultaneously assayed in one-pot. By offering the superior analytical performances over the current qRT-PCR, the isothermal NESBA technique could serve as very powerful platform technology to realize the point-of-care (POC) diagnosis for COVID-19.


Assuntos
Técnicas Biossensoriais , COVID-19 , Teste para COVID-19 , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/genética , SARS-CoV-2 , Sensibilidade e Especificidade
15.
Ann Lab Med ; 42(1): 71-78, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34374351

RESUMO

BACKGROUND: Seroprevalence studies of coronavirus disease 2019 (COVID-19) cases, including asymptomatic and past infections, are important to estimate the scale of the disease outbreak and to establish quarantine measures. We evaluated the clinical performance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody assays available in Korea for use in seroprevalence studies. METHODS: The sensitivity, specificity, cross-reactivity, and interference of five SARS-CoV-2 antibody assays were evaluated using the following: 398 serum samples from confirmed COVID-19 patients, 510 negative control samples from before 2018 (pre-pandemic), 163 serum samples from patients with SARS, Middle East respiratory syndrome (MERS), and other viral infections, and five samples for the interference study. RESULTS: The sensitivities of the five assays ranged from 92.2% to 98%, and their specificities, including cross-reactivity and interference, ranged from 97.5% to 100%. The agreement rates were excellent (kappa >0.9). Adjustment of the cutoff values could be considered through ROC curve analysis. The positive predictive values of the individual assays varied from 3.5% to 100% at a 0.1% prevalence but were as high as ≥95% when two assays were combined. CONCLUSIONS: The prevalence of COVID-19 in Korea is considered to be exceptionally low at present; thus, we recommend using a combination of two or more SARS-CoV-2 antibody assays rather than a single assay. These results could help select SARS-CoV-2 antibody assays for COVID-19 seroprevalence studies in Korea.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Pandemias , Sensibilidade e Especificidade , Estudos Soroepidemiológicos
16.
Ann Lab Med ; 42(1): 96-99, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34374354

RESUMO

The sensitivity of molecular diagnostics could be affected by nucleotide variants in pathogen genes, and the sites affected by such variants should be monitored. We report a single-nucleotide variant (SNV) in the nucleocapsid (N) gene of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), i.e., G29179T, which impairs the diagnostic sensitivity of the Xpert Xpress SARS-CoV-2 assay (Cepheid, Sunnyvale, CA, USA). We observed significant differences between the threshold cycle (Ct) values for envelope (E) and N genes and confirmed the SNV as the cause of the differences using Sanger sequencing. This SNV, G29179T, is the most prevalent in Korea and is associated with the B.1.497 virus lineage, which is dominant in Korea. Clinical laboratories should be aware of the various SNVs in the SARS-CoV-2 genome and consider their potential effects on the diagnosis of coronavirus disease 2019.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Técnicas de Diagnóstico Molecular , Nasofaringe , Nucleotídeos , Prevalência , República da Coreia , Sensibilidade e Especificidade
19.
Clin Chem ; 68(1): 153-162, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-34633030

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA quantities, measured by reverse transcription quantitative PCR (RT-qPCR), have been proposed to stratify clinical risk or determine analytical performance targets. We investigated reproducibility and how setting diagnostic cutoffs altered the clinical sensitivity of coronavirus disease 2019 (COVID-19) testing. METHODS: Quantitative SARS-CoV-2 RNA distributions [quantification cycle (Cq) and copies/mL] from more than 6000 patients from 3 clinical laboratories in United Kingdom, Belgium, and the Republic of Korea were analyzed. Impact of Cq cutoffs on clinical sensitivity was assessed. The June/July 2020 INSTAND external quality assessment scheme SARS-CoV-2 materials were used to estimate laboratory reported copies/mL and to estimate the variation in copies/mL for a given Cq. RESULTS: When the WHO-suggested Cq cutoff of 25 was applied, the clinical sensitivity dropped to about 16%. Clinical sensitivity also dropped to about 27% when a simulated limit of detection of 106 copies/mL was applied. The interlaboratory variation for a given Cq value was >1000 fold in copies/mL (99% CI). CONCLUSION: While RT-qPCR has been instrumental in the response to COVID-19, we recommend Cq (cycle threshold or crossing point) values not be used to set clinical cutoffs or diagnostic performance targets due to poor interlaboratory reproducibility; calibrated copy-based units (used elsewhere in virology) offer more reproducible alternatives. We also report a phenomenon where diagnostic performance may change relative to the effective reproduction number. Our findings indicate that the disparities between patient populations across time are an important consideration when evaluating or deploying diagnostic tests. This is especially relevant to the emergency situation of an evolving pandemic.


Assuntos
Teste de Ácido Nucleico para COVID-19/normas , COVID-19 , Ácidos Nucleicos , Bélgica , COVID-19/diagnóstico , Humanos , Ácidos Nucleicos/análise , RNA Viral/análise , Reprodutibilidade dos Testes , República da Coreia , SARS-CoV-2 , Sensibilidade e Especificidade , Reino Unido
20.
Ann Lab Med ; 41(6): 588-592, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34108286

RESUMO

The rapid antigen test (RAT) for coronavirus disease (COVID-19) represents a potent diagnostic method in situations of limited molecular testing resources. However, considerable performance variance has been reported with the RAT. We evaluated the clinical performance of Standard Q COVID-19 RAT (SQ-RAT; SD Biosensor, Suwon, Korea), the first RAT approved by the Korean Ministry of Food and Drug Safety. In total, 680 nasopharyngeal swabs previously tested using real-time reverse-transcription PCR (rRT-PCR) were retested using SQ-RAT. The clinical sensitivity of SQ-RAT relative to that of rRT-PCR was 28.7% for all specimens and was 81.4% for specimens with RNA-dependent RNA polymerase gene (RdRp) threshold cycle (Ct) values ≤23.37, which is the limit of detection of SQ-RAT. The specificity was 100%. The clinical sensitivity of SQ-RAT for COVID-19 diagnosis was assessed based on the Ct distribution at diagnosis of 33,294 COVID-19 cases in Korea extracted from the laboratory surveillance system of Korean Society for Laboratory Medicine. The clinical sensitivity of SQ-RAT for COVID-19 diagnosis in the Korean population was 41.8%. Considering the molecular testing capacity in Korea, use of the RAT for COVID-19 diagnosis appears to be limited.


Assuntos
COVID-19/diagnóstico , RNA Polimerase Dependente de RNA/genética , SARS-CoV-2/genética , COVID-19/virologia , Teste para COVID-19/métodos , Humanos , Nasofaringe/virologia , RNA Viral/análise , RNA Viral/metabolismo , Reação em Cadeia da Polimerase em Tempo Real , República da Coreia , SARS-CoV-2/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...