RESUMO
BACKGROUND: Accurate quantification of the BCR::ABL1 transcripts is essential for measurable residual disease (MRD) monitoring in chronic myeloid leukemia (CML) after tyrosine kinase inhibitor (TKI) treatment. This study evaluated the newly developed digital real-time PCR method, Dr. PCR, as an alternative reverse transcription-PCR (qRT-PCR) for MRD detection. METHODS: The performance of Dr. PCR was assessed using reference and clinical materials. Precision, linearity, and correlation with qRT-PCR were evaluated. MRD levels detected by Dr. PCR were compared with qRT-PCR, and practical advantages were investigated. RESULTS: Dr. PCR detected MRD up to 0.0032%IS (MR4.5) with excellent precision and linearity and showed a strong correlation with qRT-PCR results. Notably, Dr. PCR identified higher levels of MRD in 12.7% (29/229) of patients than qRT-PCR, including six cases of MR4, which is a critical level for TKI discontinuation. Dr. PCR also allowed for sufficient ABL1 copies in all cases, while qRT-PCR necessitated multiple repeat tests in 3.5% (8/229) of cases. CONCLUSION: Our study provides a body of evidence supporting the clinical application of Dr. PCR as a rapid and efficient method for assessing MRD in patients with CML under the current treatment regimen.