OBJECTIVE: The anatomically shaped sinus prosthesis (Uni-Graft W SINUS; Braun, Melsungen, Germany) used in valve-sparing aortic root replacement promises physiological hemodynamics believed to grant physiologic valve function. Using time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI), we analyzed sinus vortex formation and transvalvular pressure gradients in patients with sinus prosthesis compared with age-matched and young healthy volunteers. METHODS: Twelve patients with sinus prosthesis (55 ± 15 years), 12 age-matched and 6 young healthy volunteers (55 ± 6 years, 25 ± 3 years, respectively) were examined at 3T with a 4D flow magnetic resonance imaging sequence. Sinus vortices visualized by streamlines and time-resolved particle paths were graded on a 4-point Likert scale. Time resolved pressure differences of the left ventricular outflow tract and the ascending aorta to a reference point in the aortic bulb as well as the transvalvular pressure gradient were evaluated. RESULTS: 4D flow visualizations revealed a propensity of the sinus prosthesis toward intermediate (50%) and large (28%) vortices compared with age-matched volunteers with small (61%) and intermediate (36%) vortices. Vortices in sinus prostheses had a similar configuration compared with those in volunteers. The peak transvalvular pressure gradient did not vary significantly between patients and age-matched volunteers (4.0 ± 0.9 mm Hg, 3.8 ± 0.7 mm Hg, P = .373), its temporal evolution resembled that of volunteers with a prolonged positive phase in patients. CONCLUSIONS: Hemodynamics closely relating to those of volunteers were confirmed in sinus prostheses, believed to grant physiological valve function. Minor differences are presumably attributed to graft compliance and temporal resolution of the acquisition. Nevertheless, long-term deterioration of valve function as it was described for straight grafts could potentially be decelerated using sinus prostheses.


Assuntos
Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Hemodinâmica , Imageamento por Ressonância Magnética , Imagem de Perfusão/métodos , Desenho de Prótese , Adulto , Idoso , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Estudos de Casos e Controles , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...