Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuroimage Rep ; 3(2): 100175, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38357432

RESUMO

Background: Brain MRI in infants at ultra-high-field scanners might improve diagnostic quality, but safety should be evaluated first. In our previous study, we reported simulated specific absorption rates and acoustic noise data at 7 Tesla. Methods: In this study, we included twenty infants between term-equivalent age and three months of age. The infants were scanned on a 7 Tesla MRI directly after their clinically indicated 3 Tesla brain MRI scan. Vital parameters, temperature, and comfort were monitored throughout the process. Brain temperature was estimated during the MRI scans using proton MR spectroscopy. Results: We found no significant differences in vital parameters, temperature, and comfort during and after 7 Tesla MRI scans, compared to 3 Tesla MRI scans. Conclusions: These data confirm our hypothesis that scanning infants at 7 Tesla MRI appears to be safe and we identified no additional risks from scanning at 3 Tesla MRI.

2.
NMR Biomed ; 29(1): 48-56, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26620447

RESUMO

The supraclavicular fat depot is known for brown adipose tissue presence. To unravel adipose tissue physiology and metabolism, high quality and reproducible imaging is required. In this study we quantified the reliability and agreement of MRI fat fraction measurements in supraclavicular and subcutaneous adipose tissue of 25 adult patients with clinically manifest cardiovascular disease. MRI fat fraction measurements were made under ambient temperature conditions using a vendor supplied mDixon chemical-shift water-fat multi-echo pulse sequence at 1.5 T field strength. Supraclavicular fat fraction reliability (intraclass correlation coefficientagreement , ICCagreement ) was 0.97 for test-retest, 0.95 for intra-observer and 0.56 for inter-observer measurements, which increased to 0.88 when ICCconsistency was estimated. Supraclavicular fat fraction agreement displayed mean differences of 0.5% (limit of agreement (LoA) -1.7 to 2.6) for test-retest, -0.5% (LoA -2.9 to 2.0) for intra-observer and 5.6% (LoA 0.4 to 10.8) for inter-observer measurements. Median fat fraction in supraclavicular adipose tissue was 82.5% (interquartile range (IQR) 78.6-84.0) and 89.7% (IQR 87.2-91.5) in subcutaneous adipose tissue (p < 0.0001). In conclusion, water-fat MRI has good reliability and agreement to measure adipose tissue fat fraction in patients with manifest cardiovascular disease. These findings enable research on determinants of fat fraction and enable longitudinal monitoring of fat fraction within adipose tissue depots. Interestingly, even in adult patients with manifest cardiovascular disease, supraclavicular adipose tissue has a lower fat fraction compared with subcutaneous adipose tissue, suggestive of distinct morphologic characteristics, such as brown adipose tissue.


Assuntos
Tecido Adiposo/metabolismo , Doenças Cardiovasculares/metabolismo , Imageamento por Ressonância Magnética/métodos , Idoso , Doenças Cardiovasculares/patologia , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
3.
Eur Radiol ; 25(7): 1984-92, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25595641

RESUMO

OBJECTIVES: Renal denervation (RDN) is a promising therapy for resistant hypertension. RDN is assumed to decrease sympathetic activity. Consequently, RDN can potentially increase renal oxygenation. Blood oxygen level-dependent MRI (BOLD-MRI) provides a non-invasive tool to determine renal oxygenation in humans. The aim of the current study was to investigate the effect of RDN on renal oxygenation as determined by BOLD-MRI. METHODS: Patients with resistant hypertension or the inability to follow a stable drug regimen due to unacceptable side effects were included. BOLD-MRI was performed before and 12 months after RDN. Twenty-seven patients were imaged on 3 T and 19 on 1.5 T clinical MRI systems. RESULTS: Fifty-four patients were included, 46 patients (23 men, mean age 57 years) completed the study. Mean 24-h BP changed from 163(±20)/98(±14) mmHg to 154(±22)/92(±13) mmHg (p = 0.001 and p < 0.001). eGFR did not change after RDN [77(±18) vs. 79(±20) mL/min/1.73 m(2); p = 0.13]. RDN did not affect renal oxygenation [1.5 T: cortical R2*: 12.5(±0.9) vs. 12.5(±0.9), p = 0.94; medullary R2*: 19.6(±1.7) vs. 19.3(1.4), p = 0.40; 3 T: cortical R2*: 18.1(±0.8) vs. 17.8(±1.2), p = 0.47; medullary R2*: 27.4(±1.9) vs. 26.7(±1.8), p = 0.19]. CONCLUSION: The current study shows that RDN does not lead to changes in renal oxygenation 1 year after RDN as determined by BOLD-MRI. KEY POINTS: • Renal denervation significantly decreased ambulatory blood pressure. • Renal denervation did not change renal oxygenation as determined by BOLD-MRI. • Absence of a change in renal oxygenation might be explained by autoregulation.


Assuntos
Hipertensão/cirurgia , Simpatectomia/métodos , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Hipertensão/sangue , Hipertensão/fisiopatologia , Rim/inervação , Rim/fisiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Estudos Prospectivos , Respiração , Adulto Jovem
4.
Acta Neurol Scand ; 128(5): e26-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23550954

RESUMO

BACKGROUND: To assess the relationship between performance on the Paced Auditory Serial Addition Test (PASAT) and both cerebral blood flow (CBF) and axonal metabolic integrity in normal appearing white matter (NAWM) of the centrum semiovale in patients with multiple sclerosis (MS). METHODS: Normal appearing white matter of the centrum semiovale was investigated with magnetic resonance (MR) imaging in 28 non-depressed individuals (18 patients with MS and 10 healthy controls). CBF was assessed with pseudo-continuous arterial spin labeling. N-acetylacetate/creatine (NAA/Cr) ratios (a metabolic axonal marker) were measured using (1) H-MR spectroscopy. CBF was also measured in frontoparietal cortices and cerebellar hemispheres. RESULTS: In subjects with MS, we found a positive correlation between performance on the PASAT and CBF to the left centrum semiovale (P = 0.008), but not with the NAA/Cr ratio. There were no correlations between PASAT scores and CBF to the right centrum semiovale, frontoparietal cortices, and cerebellar hemispheres. There was no correlation between PASAT scores and NAA/Cr ratios. CONCLUSIONS: Our preliminary results suggest that performance on the PASAT in subjects with MS correlates with CBF to the left centrum semiovale, which contains left frontoparietal white matter association tracts involved in information processing speed and working memory.


Assuntos
Circulação Cerebrovascular/fisiologia , Esclerose Múltipla/líquido cefalorraquidiano , Esclerose Múltipla/fisiopatologia , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/líquido cefalorraquidiano , Estudos de Casos e Controles , Creatina/líquido cefalorraquidiano , Avaliação da Deficiência , Feminino , Humanos , Modelos Lineares , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Trítio
5.
NMR Biomed ; 24(9): 1038-46, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21294206

RESUMO

In vivo MRS of the human brain at ultrahigh field allows for the identification of a large number of metabolites at higher spatial resolutions than currently possible in clinical practice. However, the in vivo localization of single-voxel spectroscopy has been shown to be challenging at ultrahigh field because of the low bandwidth of refocusing radiofrequency (RF) pulses. Thus far, the proposed methods for localized MRS at 7 T suffer from long TE, inherent signal loss and/or a large chemical shift displacement artifact that causes a spatial displacement between resonances, and results in a decreased efficiency in editing sequences. In this work, we show that, by driving a standard volume coil with two RF amplifiers, focusing the B 1+ field in a certain location and using high-bandwidth adiabatic refocusing pulses, a semi-LASER (semi-localized by adiabatic selective refocusing) localization is feasible at short TE in the human brain with full signal acquisition and a low chemical shift displacement artifact at 7 T.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Prótons , Ondas de Rádio , Absorção , Simulação por Computador , Campos Eletromagnéticos , Humanos , Metaboloma , Marcadores de Spin
6.
J Neurol Neurosurg Psychiatry ; 79(9): 1027-31, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18450787

RESUMO

BACKGROUND: Suppressing the antigen-presenting capacity of glial cells could represent a novel way of reducing inflammatory activity in multiple sclerosis (MS). AIMS: To evaluate the effects of fluoxetine on new lesion formation in patients with relapsing MS. METHODS: In a double-blind, placebo-controlled exploratory study, 40 non-depressed patients with relapsing remitting or relapsing secondary progressive MS were randomised to oral fluoxetine 20 mg or placebo daily for 24 weeks. New lesion formation was studied by assessing the cumulative number of gadolinium-enhancing lesions on brain MRI performed on weeks 4, 8, 16 and 24. RESULTS: Nineteen patients in both groups completed the study. The mean (SD) cumulative number of new enhancing lesions during the 24 weeks of treatment was 1.84 (2.9) in the fluoxetine group and 5.16 (8.6) in the placebo group (p = 0.15). The number of scans showing new enhancing lesions was 25% in the fluoxetine group versus 41% in the placebo group (p = 0.04). Restricting the analysis to the past 16 weeks of treatment showed that the cumulative number of new enhancing lesions was 1.21 (2.6) in the fluoxetine group and 3.16 (5.3) in the placebo group (p = 0.05). The number of patients without enhancing lesions was 63% in the fluoxetine group versus 26% in the placebo group (p = 0.02). CONCLUSIONS: This proof-of-concept study shows that fluoxetine tends to reduce the formation of new enhancing lesions in patients with MS. Further studies with this compound are warranted. TRIAL REGISTRATION: Number: ISRCTN65586975.


Assuntos
Fluoxetina/uso terapêutico , Inflamação/prevenção & controle , Esclerose Múltipla Crônica Progressiva/tratamento farmacológico , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Inibidores Seletivos de Recaptação de Serotonina/uso terapêutico , Adulto , Encéfalo/patologia , Método Duplo-Cego , Feminino , Humanos , Inflamação/epidemiologia , Inflamação/patologia , Imageamento por Ressonância Magnética , Masculino , Esclerose Múltipla Crônica Progressiva/epidemiologia , Esclerose Múltipla Recidivante-Remitente/epidemiologia
7.
Eur Radiol ; 18(8): 1736-40, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18389250

RESUMO

N-acetylaspartate/creatine (NAA/Cr) ratios, assessed with proton magnetic resonance spectroscopy, are increasingly used as a surrogate marker for axonal dysfunction and degeneration in multiple sclerosis (MS). The purpose of this study was to test short-time reproducibility of NAA/Cr ratios in patients with clinically stable MS. In 35 MS patients we analysed NAA/Cr ratios obtained with (1)H-MR spectroscopic imaging at the centrum semiovale either with lateral ventricles partially included (group 1; n=15) or more cranially with no ventricles included (group 2; n=20). To test short-term reproducibility of the NAA/Cr measurements, patients were scanned twice 4 weeks apart. We determined mean NAA/Cr and Cho/Cr ratios of 12 grey matter and 24 white matter voxels. Mean NAA/Cr ratios of both the white and grey matter did not change after 4 weeks. Overall 4-week reproducibility of the NAA/Cr ratio, expressed as coefficient of variation, was 4.8% for grey matter and 3.5% for white matter. Reproducibility of cranial scanning of the ventricles was slightly better than with cerebrospinal fluid included. Our study shows good short-term reproducibility of NAA/Cr ratio measurements in the centrum semiovale, which supports the reliability of this technique for longitudinal studies.


Assuntos
Ácido Aspártico/análogos & derivados , Creatinina/análise , Espectroscopia de Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/metabolismo , Adulto , Ácido Aspártico/análise , Biomarcadores/análise , Feminino , Humanos , Masculino , Prótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Neuroimage ; 32(2): 676-83, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16757183

RESUMO

Sensory stimuli may elicit a widely distributed parietal-premotor circuitry underlying task-related movements such as grasping. These stimuli include the visual presentation of an object to be grasped, as well as the observation of grasping performed by others. In this study, we used functional Magnetic Resonance Imaging (fMRI) to test whether the performance of simple finger flexion, contrasted to extension, might similarly activate higher-order circuitry associated with grasping. Statistical Parametric Mapping (SPM) showed that flexion, compared to extension, was related with significant activation of the left posterior parietal cortex and posterior insula, bilaterally. This pattern supported our hypothesis that simple finger flexion has a specific relation with circuitry involved in preparing manual tasks. Although the two motor conditions showed major overlap in the primary motor cortex, increased flexion-related activation at the precentral motor-premotor junction further supported its association with higher-order motor control.


Assuntos
Dominância Cerebral/fisiologia , Dedos/inervação , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Contração Isométrica/fisiologia , Imageamento por Ressonância Magnética , Córtex Motor/fisiologia , Oxigênio/sangue , Lobo Parietal/fisiologia , Córtex Somatossensorial/fisiologia , Adulto , Mapeamento Encefálico , Feminino , Lateralidade Funcional/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Rede Nervosa/fisiologia , Córtex Pré-Frontal/fisiologia
9.
Neuroimage ; 30(1): 203-13, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16290018

RESUMO

Simultaneous recording of electroencephalogram/functional magnetic resonance images (EEG/fMRI) was applied to identify blood oxygenation level-dependent (BOLD) changes associated with spontaneous variations of the alpha rhythm, which is considered the hallmark of the brain resting state. The analysis was focused on inter-subject variability associated with the resting state. Data from 7 normal subjects are presented. Confirming earlier findings, three subjects showed a negative correlation between the BOLD signal and the average power time series within the alpha band (8--12 Hz) in extensive areas of the occipital, parietal and frontal lobes. In small thalamic areas, the BOLD signal was positively correlated with the alpha power. For subjects 3 and 4, who displayed two different states during the data acquisition time, it was shown that the corresponding correlation patterns were different, thus demonstrating the state dependency of the results. In subject 5, the changes in BOLD were observed mainly in the frontal and temporal lobes. Subject 6 only showed positive correlations, thus contradicting the negative BOLD alpha power cortical correlations that were found in most subjects. Results suggest that the resting state varies over subjects and, sometimes, even within one subject. As the resting state plays an important role in many fMRI experiments, the inter-subject variability of this state should be addressed when comparing fMRI results from different subjects.


Assuntos
Ritmo alfa , Córtex Cerebral/fisiologia , Eletroencefalografia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Oxigênio/sangue , Processamento de Sinais Assistido por Computador , Adulto , Mapeamento Encefálico , Córtex Cerebral/irrigação sanguínea , Feminino , Humanos , Masculino , Padrões de Referência , Sensibilidade e Especificidade , Estatística como Assunto , Tálamo/irrigação sanguínea , Tálamo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...