Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 35(15): 2146-54, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24431209

RESUMO

A new MCE method for the determination of oxalic, citric, glycolic, lactic, and 2- and 3-hydroxybutyric acids, indicators of some metabolic and neurological diseases, in cerebrospinal fluid (CSF) was developed. MCE separations were performed on a PMMA microchip with coupled channels at lower pH (5.5) to prevent proteins interference. A double charged counter-ion, BIS-TRIS propane, was very effective in resolving the studied organic acids. The limits of detection (S/N = 3) ranging from 0.1 to 1.6 µM were obtained with the aid of contact conductivity detector implemented directly on the microchip. RSDs for migration time and peak area of organic acids in artificial and CSF samples were <0.8 and <9.7%, respectively. Recoveries of organic acids in untreated CSF samples on the microchip varied from 91 to 104%. Elimination of chloride interference, a major anionic constituent of CSF, has been reached by two approaches: (i) the use of coupled channels microchip in a column switching mode when approximately 97-99% of chloride was removed electrophoretically in the first separation channel and (ii) the implementation of micro-SPE with silver-form resin prior to the MCE analysis, which selectively removed chloride from undeproteinized CSF samples.


Assuntos
Ácidos Acíclicos/líquido cefalorraquidiano , Eletroforese em Microchip/métodos , Ácidos Acíclicos/química , Ácidos Acíclicos/isolamento & purificação , Ácidos Acíclicos/metabolismo , Condutividade Elétrica , Eletroforese em Microchip/instrumentação , Humanos , Reprodutibilidade dos Testes , Microextração em Fase Sólida
2.
Artigo em Inglês | MEDLINE | ID: mdl-23727865

RESUMO

A new method for the determination of nitrite and nitrate, indicators of various neurological diseases (meningitis, multiple sclerosis, Parkinson's disease) in cerebrospinal fluid (CSF) on an electrophoresis chip was developed. An on-line combination of isotachophoresis (ITP) with capillary electrophoresis (CE) on a poly(methylmethacrylate) chip assembled with coupled separation channels (CC) and contact conductivity detectors was employed. ITP separations performed at low pH (3.6) in the first separation channel enabled a highly selective transfer of the analytes to the second CE stage working under micellar conditions implemented by zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)-propanesulfonate. The proposed method achieved low limits of detection varied from 0.2 to 0.4µgL(-1) when the sample volume injected onto the chip (9.9µl) was almost the same as the volume of both separation channels. Preferable working conditions on the CC chip (suppressed hydrodynamic and electroosmotic flow) contributed for reproducible migration velocities (intra-day reproducibility up to 2.1% RSD) and determinations of trace concentrations of nitrite and nitrate (intra-day precision up to 3.0% RSD). Huge amount of chloride present in CSF (approx. 4.5gL(-1)) was removed from analyzed CSF samples by microsolid phase extraction performed on silver-form resin prior to the ITP-CE analysis. Developed method provided fast (approx. 20min total analysis time) and reliable determinations of trace nitrite and nitrate and could be fully integrated into the analysis of CSF samples.


Assuntos
Eletroforese em Microchip/métodos , Nitratos/líquido cefalorraquidiano , Nitritos/líquido cefalorraquidiano , Microextração em Fase Sólida/métodos , Adolescente , Adulto , Biomarcadores/líquido cefalorraquidiano , Eletroforese em Microchip/instrumentação , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Doenças Neurodegenerativas/líquido cefalorraquidiano , Reprodutibilidade dos Testes
3.
J Sep Sci ; 35(5-6): 674-80, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22271676

RESUMO

A new method for the determination of trace glyphosate (GLYP), non-selective pesticide, by CZE with online ITP pre-treatment of drinking waters on a column-coupling (CC) chip has been developed. CC chip was equipped with two injection channels of 0.9 and 9.9 µL volumes, two separation channels of 9.3 µL total volume and a pair of conductivity detectors. A very effective ITP sample clean-up performed in the first channel at low pH (3.2) was introduced for quick CZE resolution and detection of GLYP carried out at higher pH (6.1) in the second channel on the CC chip. The LOD for GLYP was estimated at 2.5 µg/L (15 nmol/L) using a 9.9 |mL volume of the injection channel. ITP-CZE analyses of model and real samples have provided very favorable intra-day (0.1-1.2% RSD) and inter-day (2.9% RSD) repeatabilities of the migration time for GLYP while 0.2-6.9% RSD values were typical for the peak area data. Recoveries of GLYP in spiked drinking water varied in the range of 99-109%. A minimum pre-treatment of drinking water (degassing and dilution) and a short analysis time (ca. 10 min) were distinctive features of ITP-CZE determinations of GLYP on the CC chip with high sample volume loaded, as well.


Assuntos
Eletroforese Capilar/métodos , Glicina/análogos & derivados , Praguicidas/análise , Poluentes Químicos da Água/análise , Eletroforese Capilar/instrumentação , Glicina/análise , Glifosato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...