We investigated 4 cases of legionnaires' disease (LD) reported among workers at an Ohio automotive plant in March 2001. A "confirmed" case of LD was defined as x-ray-confirmed pneumonia and a confirmatory laboratory test. A "possible" case of LD was defined as elevated titers of antibody and respiratory symptoms. Legionella pneumophila serogroup 1 (LP1) was isolated from 1 case patient. Legionella was isolated from 18 (9%) of 197 environmental samples; 3 isolates were LP1 but did not match the case isolate. We conducted a case-control study; 17 case patients with confirmed or possible LD and 86 control subjects (workers with low antibody titers and without symptoms) were enrolled. Visiting a specific cleaning line (odds ratio, [OR], 7.29; 95% confidence interval [CI], 2.31-23.00) and working in the cleaning region of the plant (OR, 3.22; 95% CI, 1.11-9.38) were associated with LD. LD can be transmitted in industrial settings in which aerosols are produced. Clinicians should consider LD when treating persons from these settings for pneumonia.


Assuntos
Surtos de Doenças , Indústrias , Legionella pneumophila , Doença dos Legionários/epidemiologia , Doenças Profissionais/epidemiologia , Aerossóis , Automóveis , Estudos de Casos e Controles , Intervalos de Confiança , Humanos , Doença dos Legionários/diagnóstico , Doenças Profissionais/diagnóstico , Razão de Chances , Ohio/epidemiologia , Fatores de Risco