Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 106: 72-4, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26275798

RESUMO

Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error.


Assuntos
Terapia por Captura de Nêutron de Boro , Ouro/química , Nêutrons
2.
Appl Radiat Isot ; 106: 92-4, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26253274

RESUMO

Liquid lithium (Li) is a candidate material for a target of intense neutron source, heat transfer medium in space engines and charges stripper. For a medical application of BNCT, epithermal neutrons with least energetic neutrons and γ-ray are required so as to avoid unnecessary doses to a patient. This is enabled by lithium target irradiated by protons at 2.5 MeV range, with utilizing the threshold reaction of (7)Li(p,n)(7)Be at 1.88 MeV. In the system, protons at 2.5 MeV penetrate into Li layer by 0.25 mm with dissipating heat load near the surface. To handle it, thin film flow of high velocity is important for stable operation. For the proton accelerator, electrostatic type of the Schnkel or the tandem is planned to be employed. Neutrons generated at 0.6 MeV are gently moderated to epithermal energy while suppressing accompanying γ-ray minimum by the dedicated moderator assembly.


Assuntos
Terapia por Captura de Nêutron de Boro , Lítio/química , Nêutrons
3.
Br J Ophthalmol ; 88(6): 826-31, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15148220

RESUMO

BACKGROUND/AIMS: To evaluate treatment with high peak power pulse energy by femtosecond ultrashort pulse laser (titanium sapphire laser) delivered at an 800 nm wavelength for corneal neovascularisation using photodynamic therapy (PDT) mediated by indocyanine green (ICG). METHODS: Using a gelatin solid as an in vitro corneal model, the safety of laser power was studied to determine if it degenerated gelatin with or without ICG. The authors then induced corneal neovascularisation in rabbit eyes by an intracorneal suturing technique. Fluorescein angiography was used to evaluate occlusion before PDT and 0, 1, 3, and 10 days after PDT. The authors performed light microscopy with haematoxylin eosin staining and transmission electron microscopy to determine thrombosis formation in the neovascular regions. RESULTS: The threshold of peak laser power density ranged from 39 to 53 W/cm(2). Laser irradiation was started 30 seconds after a 10 mg/kg ICG injection, and all irradiated segments were occluded at 0, 1, 3, and 10 days at 3.8 J/cm(2). Light and electron microscopy documented thrombosis formation in the neovascular region. CONCLUSION: Femtosecond pulse laser enhanced by ICG can be used for PDT. Because of effective closure of corneal neovascularisation at a low energy level, the high peak power pulse energy of the femtosecond pulse laser might be more efficacious than continuous wave laser for use with PDT.


Assuntos
Neovascularização da Córnea/cirurgia , Fotocoagulação a Laser/métodos , Animais , Corantes/uso terapêutico , Córnea/patologia , Neovascularização da Córnea/tratamento farmacológico , Neovascularização da Córnea/patologia , Angiofluoresceinografia , Gelatina , Verde de Indocianina/uso terapêutico , Microscopia Eletrônica , Modelos Animais , Fotoquimioterapia , Coelhos , Trombose/patologia
4.
Rev Sci Instrum ; 50(11): 1453, 1979 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18699409

RESUMO

Experimental studies were made on the cooling of extraction electrodes of an ion source in the case of long-pulse operation. Copper electrodes with forced water cooling pipes were tested under the condition that an ion beam of 1 to 5 A at 30 keV was extracted for up to 10 s. The average heat loading to the grid are of the electrode was as high as 130 W/cm2. This high heat flux was obtained by a set of electrodes artificially arranged to produce poor beam optics, and hence the high heat loading. Temperature of the ground electrode was measured at two points by thermocouples buried and silver brazed in it, and was kept below 230 degrees C due to a large boiling heat transfer coefficient of the cooling water. No evidences of deformation or deterioration of the electrodes was observed after repetitious beam extraction. This heat loading was still a half of that on the grid of the ion source for the JT-60 NBI.