Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 124(12): 120403, 2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-32281864

RESUMO

We describe a Sagnac interferometer suitable for rotation sensing, implemented using an atomic Bose-Einstein condensate confined in a harmonic magnetic trap. The atom wave packets are split and recombined by standing-wave Bragg lasers, and the trapping potential steers the packets along circular trajectories with a radius of 0.2 mm. Two conjugate interferometers are implemented simultaneously to provide common-mode rejection of noise and to isolate the rotation signal. With interference visibilities of about 50%, we achieve a rotation sensitivity comparable to Earth's rate in about 10 min of operation. Gyroscope operation was demonstrated by rotating the optical table on which the experiment was performed.

2.
Rev Sci Instrum ; 88(1): 013102, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147663

RESUMO

We present a variant of the time-orbiting potential trap suitable for Bose-Einstein condensate atom interferometers, which provides weak, cylindrically symmetric confinement as well as support for the atoms against gravity. This trapping configuration is well-suited for the implementation of a compact atom interferometer based gyroscope. The trap is made up of six coils, which were produced using photolithographic techniques and take up a modest volume of approximately 1 cubic inch inside a vacuum chamber. The trapping frequencies and thermal characteristics of the trap are presented, showing cylindrical symmetry and scalability of the trapping frequencies from 1 Hz to 8 Hz in the symmetry plane.

3.
Rev Sci Instrum ; 87(6): 063105, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27370424

RESUMO

Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 µs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the (87)Rb recoil frequency.

4.
Am J Hypertens ; 3(3): 240-1, 1990 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2322436

RESUMO

Seated BP measurements were taken in 48 men with a history of essential hypertension: in a chair with back support v on an examining table with no back support, and with bell v diaphragm stethoscope head in each condition. There were no significant differences between bell and diaphragm in SBP or DBP determinations. SBP was not significantly different between table and chair, but table DBP was 6.5 mm Hg higher (P less than .0001) than chair DBP. We conclude that back support, but not bell v diaphragm stethoscope head, affects seated BP determinations.


Assuntos
Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Dorso , Humanos , Masculino , Postura
5.
J R Coll Gen Pract ; 37(300): 301-4, 1987 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3449631

RESUMO

Two doctors in a five-partner urban practice recorded details of their out-of-hours telephone calls for a year. No caller was refused a visit, but 474 of the 809 incoming calls (59%) were managed by telephone advice, an unexpectedly high proportion. Although these callers were instructed to telephone again if still worried, only 40 did so during the same duty period, and only 55% of a smaller sample of patients receiving telephone advice only consulted again within a week. No evident detriment to patients' health was observed. Thirty nine (5%) of the 809 incoming calls were managed by an out-of-hours surgery attendance and 296(37%) by a home visit. The urgency of the visits made was categorized retrospectively as high (34% of visits), medium (39%) and low (27%). It is hoped that this descriptive account will foster discussion of the value and implications of telephone advice in managing out-of-hours calls.


Assuntos
Medicina de Família e Comunidade , Prática Associada/organização & administração , Aceitação pelo Paciente de Cuidados de Saúde , Telefone , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Visita Domiciliar , Humanos , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Fatores de Tempo , Reino Unido
6.
Science ; 219(4588): 1020, 1983 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-17811727
7.
Physiol Chem Phys Med NMR ; 15(2): 167-75, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-6665045

RESUMO

The maximum allowable concentration of any chemical substance can be estimated with some degree of confidence solely on the basis of the chemical groups and structure it contains. The derivation of this methodology from the U. S. Dept. of Labor Occupational Health and Environmental Control Air Contaminants List (1972) is described.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Animais , Humanos , Dose Letal Mediana , Concentração Máxima Permitida , Relação Estrutura-Atividade
10.
Science ; 194(4272): 1377, 1976 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-17819259
11.
Science ; 177(4055): 1152-3, 1972 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-17847188
13.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...