1.
Nat Biotechnol ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302753

RESUMO

Mass spectrometry (MS)-based proteomics aims to characterize comprehensive proteomes in a fast and reproducible manner. Here we present the narrow-window data-independent acquisition (nDIA) strategy consisting of high-resolution MS1 scans with parallel tandem MS (MS/MS) scans of ~200 Hz using 2-Th isolation windows, dissolving the differences between data-dependent and -independent methods. This is achieved by pairing a quadrupole Orbitrap mass spectrometer with the asymmetric track lossless (Astral) analyzer which provides >200-Hz MS/MS scanning speed, high resolving power and sensitivity, and low-ppm mass accuracy. The nDIA strategy enables profiling of >100 full yeast proteomes per day, or 48 human proteomes per day at the depth of ~10,000 human protein groups in half-an-hour or ~7,000 proteins in 5 min, representing 3× higher coverage compared with current state-of-the-art MS. Multi-shot acquisition of offline fractionated samples provides comprehensive coverage of human proteomes in ~3 h. High quantitative precision and accuracy are demonstrated in a three-species proteome mixture, quantifying 14,000+ protein groups in a single half-an-hour run.

2.
Anal Chem ; 91(5): 3611-3618, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30688442

RESUMO

Native mass spectrometry continues to develop as a significant complement to traditional structural biology techniques. Within native mass spectrometry (MS), surface-induced dissociation (SID) has been shown to be a powerful activation method for the study of noncovalent complexes of biological significance. High-resolution mass spectrometers have become increasingly adapted to the analysis of high-mass ions and have demonstrated their importance in understanding how small mass changes can affect the overall structure of large biomolecular complexes. Herein we demonstrate the first adaptation of surface-induced dissociation in a modified high-mass-range, high-resolution Orbitrap mass spectrometer. The SID device was designed to be installed in the Q Exactive series of Orbitrap mass spectrometers with minimal disruption of standard functions. The performance of the SID-Orbitrap instrument has been demonstrated with several protein complex and ligand-bound protein complex systems ranging from 53 to 336 kDa. We also address the effect of ion source temperature on native protein-ligand complex ions as assessed by SID. Results are consistent with previous findings on quadrupole time-of-flight instruments and suggest that SID coupled to high-resolution MS is well-suited to provide information on the interface interactions within protein complexes and ligand-bound protein complexes.


Assuntos
Espectrometria de Massas/instrumentação , Complexos Multiproteicos/química , Íons , Ligantes , Espectrometria de Massas/métodos , Ligação Proteica , Propriedades de Superfície , Temperatura
3.
Nat Methods ; 14(12): 1175-1183, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29131162

RESUMO

We report the development of a 3D OrbiSIMS instrument for label-free biomedical imaging. It combines the high spatial resolution of secondary ion mass spectrometry (SIMS; under 200 nm for inorganic species and under 2 µm for biomolecules) with the high mass-resolving power of an Orbitrap (>240,000 at m/z 200). This allows exogenous and endogenous metabolites to be visualized in 3D with subcellular resolution. We imaged the distribution of neurotransmitters-gamma-aminobutyric acid, dopamine and serotonin-with high spectroscopic confidence in the mouse hippocampus. We also putatively annotated and mapped the subcellular localization of 29 sulfoglycosphingolipids and 45 glycerophospholipids, and we confirmed lipid identities with tandem mass spectrometry. We demonstrated single-cell metabolomic profiling using rat alveolar macrophage cells incubated with different concentrations of the drug amiodarone, and we observed that the upregulation of phospholipid species and cholesterol is correlated with the accumulation of amiodarone.


Assuntos
Dopamina/análise , Hipocampo/metabolismo , Imagem Molecular/métodos , Serotonina/análise , Frações Subcelulares/metabolismo , Ácido gama-Aminobutírico/análise , Amiodarona/metabolismo , Animais , Células Cultivadas , Desenho de Equipamento , Feminino , Glicerofosfolipídeos/análise , Imageamento Tridimensional , Macrófagos Alveolares/metabolismo , Metabolômica/instrumentação , Metabolômica/métodos , Camundongos , Imagem Molecular/instrumentação , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Sulfoglicoesfingolipídeos/análise , Espectrometria de Massas em Tandem
4.
Nat Methods ; 13(3): 237-40, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26780093

RESUMO

Efforts to map the human protein interactome have resulted in information about thousands of multi-protein assemblies housed in public repositories, but the molecular characterization and stoichiometry of their protein subunits remains largely unknown. Here, we report a computational search strategy that supports hierarchical top-down analysis for precise identification and scoring of multi-proteoform complexes by native mass spectrometry.


Assuntos
Mineração de Dados/métodos , Bases de Dados de Proteínas , Espectrometria de Massas/métodos , Mapeamento de Interação de Proteínas/métodos , Proteoma/metabolismo , Análise de Sequência de Proteína/métodos , Algoritmos , Sequência de Aminoácidos , Sítios de Ligação , Simulação por Computador , Modelos Químicos , Dados de Sequência Molecular , Ligação Proteica
5.
Anal Chem ; 86(20): 10036-43, 2014 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-25208235

RESUMO

Identification of unknown compounds is of critical importance in GC/MS applications (metabolomics, environmental toxin identification, sports doping, petroleomics, and biofuel analysis, among many others) and remains a technological challenge. Derivation of elemental composition is the first step to determining the identity of an unknown compound by MS, for which high accuracy mass and isotopomer distribution measurements are critical. Here, we report on the development of a dedicated, applications-grade GC/MS employing an Orbitrap mass analyzer, the GC/Quadrupole-Orbitrap. Built from the basis of the benchtop Orbitrap LC/MS, the GC/Quadrupole-Orbitrap maintains the performance characteristics of the Orbitrap, enables quadrupole-based isolation for sensitive analyte detection, and includes numerous analysis modalities to facilitate structural elucidation. We detail the design and construction of the instrument, discuss its key figures-of-merit, and demonstrate its performance for the characterization of unknown compounds and environmental toxins.


Assuntos
Espectrometria de Massas/instrumentação , Desenho de Equipamento
6.
Anal Chem ; 85(23): 11163-73, 2013 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-24237199

RESUMO

Native mass spectrometry (MS) is becoming an important integral part of structural proteomics and system biology research. The approach holds great promise for elucidating higher levels of protein structure: from primary to quaternary. This requires the most efficient use of tandem MS, which is the cornerstone of MS-based approaches. In this work, we advance a two-step fragmentation approach, or (pseudo)-MS(3), from native protein complexes to a set of constituent fragment ions. Using an efficient desolvation approach and quadrupole selection in the extended mass-to-charge (m/z) range, we have accomplished sequential dissociation of large protein complexes, such as phosporylase B (194 kDa), pyruvate kinase (232 kDa), and GroEL (801 kDa), to highly charged monomers which were then dissociated to a set of multiply charged fragmentation products. Fragment ion signals were acquired with a high resolution, high mass accuracy Orbitrap instrument that enabled highly confident identifications of the precursor monomer subunits. The developed approach is expected to enable characterization of stoichiometry and composition of endogenous native protein complexes at an unprecedented level of detail.


Assuntos
Espectrometria de Massas/métodos , Subunidades Proteicas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas/tendências , Fosforilase b/análise , Fosforilase b/química , Subunidades Proteicas/química , Proteômica/métodos , Proteômica/tendências , Espectrometria de Massas por Ionização por Electrospray/tendências , Espectrometria de Massas em Tandem/tendências
7.
Anal Chem ; 85(24): 11710-4, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24251866

RESUMO

Proteome coverage and peptide identification rates have historically advanced in line with improvements to the detection limits and acquisition rate of the mass spectrometer. For a linear ion trap/Orbitrap hybrid, the acquisition rate has been limited primarily by the duration of the ion accumulation and analysis steps. It is shown here that the spectral acquisition rate can be significantly improved through extensive parallelization of the acquisition process using a novel mass spectrometer incorporating quadrupole, Orbitrap, and linear trap analyzers. Further, these improvements to the acquisition rate continue to enhance proteome coverage and general experimental throughput.


Assuntos
Espectrometria de Massas/métodos , Peptídeos/análise , Proteômica/métodos , Espectrometria de Massas/instrumentação , Peptídeos/química , Proteômica/instrumentação , Fatores de Tempo
8.
Rapid Commun Mass Spectrom ; 27(17): 1904-12, 2013 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-23939956

RESUMO

RATIONALE: In sports drug testing, comprehensive studies on the metabolism of therapeutic agents with misuse potential are necessary to identify metabolites that provide utmost retrospectivity and specificity. By commonly employed approaches minor and/or long-term metabolites in urine might remain undetected. Hence, an alternative strategy to unambiguously identify the majority of urinary metabolites including low-abundance representatives is desirable. METHODS: Urine samples were collected for 20 days during an elimination study with an oral dose of 5 mg of 17α-C(2)H3-metandienone. The specimens were processed according to established sample preparation procedures (including fractionation and deconjugation) and subjected to gas chromatography/hydrogen isotope ratio mass spectrometry (GC/IRMS) analysis. Due to the deuteration of the administered drug, urinary metabolites bearing the deuterium label yield abundant and specific signals on the GC/IRMS instrument resulting from the substantially altered (2)H/(1)H ratio. The sample aliquots were measured by gas chromatography/time-of-flight (GC/Q-TOF) mass spectrometry using identical GC conditions, allowing high-resolution/high-accuracy mass data to be obtained on all urinary metabolites previously identified by IRMS. RESULTS: Within the IRMS chromatograms, labeled metabolites were identified up to 20 days after administration at urinary concentration down to 0.25 ng/mL. More than 50 metabolites were observed with the earlier described long-term metabolite of metandienone, 18-nor-17ß-hyroxymethyl,17α-methyl-androst-1,4,13-trien-3-one, being the most prominent glucuronidated metabolite in the studied time window. In the sulfoconjugated steroids fraction, a yet unknown metabolite was observed at m/z 283.1997 comprising the experimentally determined elemental composition of C20H21(2)H3O. CONCLUSIONS: Combining IRMS with high-resolution mass spectrometry considerably facilitates and accelerates metabolite identification of deuterium-labeled compounds in urine. Of particular relevance in doping control, the principle is applicable also to other arenas of drug research, allowing the preparation and administration of e.g. radioactively labeled substances to be omitted.


Assuntos
Anabolizantes/química , Anabolizantes/metabolismo , Cromatografia Gasosa/métodos , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Anabolizantes/urina , Dopagem Esportivo/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Estrutura Molecular
9.
Mol Cell Proteomics ; 11(3): O112.017731, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22311636

RESUMO

The term "proteomics" encompasses the large-scale detection and analysis of proteins and their post-translational modifications. Driven by major improvements in mass spectrometric instrumentation, methodology, and data analysis, the proteomics field has burgeoned in recent years. It now provides a range of sensitive and quantitative approaches for measuring protein structures and dynamics that promise to revolutionize our understanding of cell biology and molecular mechanisms in both human cells and model organisms. The Proteomics Specification in Time and Space (PROSPECTS) Network is a unique EU-funded project that brings together leading European research groups, spanning from instrumentation to biomedicine, in a collaborative five year initiative to develop new methods and applications for the functional analysis of cellular proteins. This special issue of Molecular and Cellular Proteomics presents 16 research papers reporting major recent progress by the PROSPECTS groups, including improvements to the resolution and sensitivity of the Orbitrap family of mass spectrometers, systematic detection of proteins using highly characterized antibody collections, and new methods for absolute as well as relative quantification of protein levels. Manuscripts in this issue exemplify approaches for performing quantitative measurements of cell proteomes and for studying their dynamic responses to perturbation, both during normal cellular responses and in disease mechanisms. Here we present a perspective on how the proteomics field is moving beyond simply identifying proteins with high sensitivity toward providing a powerful and versatile set of assay systems for characterizing proteome dynamics and thereby creating a new "third generation" proteomics strategy that offers an indispensible tool for cell biology and molecular medicine.


Assuntos
Biologia Celular , Espectrometria de Massas/métodos , Proteoma/análise , Proteoma/metabolismo , Proteômica/métodos , Humanos , Processamento de Proteína Pós-Traducional , Fatores de Tempo
10.
Mol Cell Proteomics ; 11(3): O111.013698, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22159718

RESUMO

Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust operation. The tandem MS acquisition speed of the dual cell linear ion trap now exceeds 12 Hz. Most importantly, the resolving power of the Orbitrap analyzer has been increased twofold for the same transient length by employing a compact, high-field Orbitrap analyzer that almost doubles the observed frequencies. An enhanced Fourier Transform algorithm-incorporating phase information-further doubles the resolving power to 240,000 at m/z 400 for a 768 ms transient. For top-down experiments, we combine a survey scan with a selected ion monitoring scan of the charge state of the protein to be fragmented and with several HCD microscans. Despite the 120,000 resolving power for SIM and HCD scans, the total cycle time is within several seconds and therefore suitable for liquid chromatography tandem MS. For bottom-up proteomics, we combined survey scans at 240,000 resolving power with data-dependent collision-induced dissociation of the 20 most abundant precursors in a total cycle time of 2.5 s-increasing protein identifications in complex mixtures by about 30%. The speed of the Orbitrap Elite furthermore allows scan modes in which complementary dissociation mechanisms are routinely obtained of all fragmented peptides.


Assuntos
Cromatografia Líquida , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/metabolismo , Proteoma/análise , Proteoma/metabolismo , Proteômica/instrumentação , Espectrometria de Massas em Tandem/instrumentação , Células HeLa , Humanos , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos
11.
Mol Cell Proteomics ; 10(9): M111.011015, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21642640

RESUMO

Mass spectrometry-based proteomics has greatly benefitted from enormous advances in high resolution instrumentation in recent years. In particular, the combination of a linear ion trap with the Orbitrap analyzer has proven to be a popular instrument configuration. Complementing this hybrid trap-trap instrument, as well as the standalone Orbitrap analyzer termed Exactive, we here present coupling of a quadrupole mass filter to an Orbitrap analyzer. This "Q Exactive" instrument features high ion currents because of an S-lens, and fast high-energy collision-induced dissociation peptide fragmentation because of parallel filling and detection modes. The image current from the detector is processed by an "enhanced Fourier Transformation" algorithm, doubling mass spectrometric resolution. Together with almost instantaneous isolation and fragmentation, the instrument achieves overall cycle times of 1 s for a top 10 higher energy collisional dissociation method. More than 2500 proteins can be identified in standard 90-min gradients of tryptic digests of mammalian cell lysate- a significant improvement over previous Orbitrap mass spectrometers. Furthermore, the quadrupole Orbitrap analyzer combination enables multiplexed operation at the MS and tandem MS levels. This is demonstrated in a multiplexed single ion monitoring mode, in which the quadrupole rapidly switches among different narrow mass ranges that are analyzed in a single composite MS spectrum. Similarly, the quadrupole allows fragmentation of different precursor masses in rapid succession, followed by joint analysis of the higher energy collisional dissociation fragment ions in the Orbitrap analyzer. High performance in a robust benchtop format together with the ability to perform complex multiplexed scan modes make the Q Exactive an exciting new instrument for the proteomics and general analytical communities.


Assuntos
Espectrometria de Massas , Fragmentos de Peptídeos/análise , Proteínas/análise , Proteômica/métodos , Algoritmos , Sequência de Aminoácidos , Feminino , Células HeLa , Humanos , Íons , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Dados de Sequência Molecular , Fragmentos de Peptídeos/química , Proteínas/química
12.
Mol Cell Proteomics ; 8(12): 2759-69, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19828875

RESUMO

Since its introduction a few years ago, the linear ion trap Orbitrap (LTQ Orbitrap) instrument has become a powerful tool in proteomics research. For high resolution mass spectrometry measurements ions are accumulated in the linear ion trap and passed on to the Orbitrap analyzer. Simultaneously with acquisition of this signal, the major peaks are isolated in turn, fragmented and recorded at high sensitivity in the linear ion trap, combining the strengths of both mass analyzer technologies. Here we describe a next generation LTQ Orbitrap system termed Velos, with significantly increased sensitivity and scan speed. This is achieved by a vacuum interface using a stacked ring radio frequency ion guide with 10-fold higher transfer efficiency in MS/MS mode and 3-5-fold in full scan spectra, by a dual pressure ion trap configuration, and by reduction of overhead times between scans. The first ion trap efficiently captures and fragments ions at relatively high pressure whereas the second ion trap realizes extremely fast scan speeds at reduced pressure. Ion injection times for MS/MS are predicted from full scans instead of performing automatic gain control scans. Together these improvements routinely enable acquisition of up to ten fragmentation spectra per second. Furthermore, an improved higher-energy collisional dissociation cell with increased ion extraction capabilities was implemented. Higher-collision energy dissociation with high mass accuracy Orbitrap readout is as sensitive as ion trap MS/MS scans in the previous generation of the instrument.


Assuntos
Espectrometria de Massas/instrumentação , Pressão , Proteômica/instrumentação , Análise de Sequência de Proteína/instrumentação , Sequência de Aminoácidos , Animais , Anidrases Carbônicas/química , Bovinos , Células HeLa , Humanos , Dados de Sequência Molecular , Peptídeos/química , Soroalbumina Bovina/química , Fatores de Tempo
13.
J Proteome Res ; 7(8): 3127-36, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18613715

RESUMO

Here we detail the modification of a quadrupole linear ion trap-orbitrap hybrid (QLT-orbitrap) mass spectrometer to accommodate a negative chemical ionization (NCI) source. The NCI source is used to produce fluoranthene radical anions for imparting electron transfer dissociation (ETD). The anion beam is stable, robust, and intense so that a sufficient amount of reagents can be injected into the QLT in only 4-8 ms. Following ion/ion reaction in the QLT, ETD product ions are mass-to-charge (m/z) analyzed in either the QLT (for speed and sensitivity) or the orbitrap (for mass resolution and accuracy). Here we describe the physical layout of this device, parametric optimization of anion transport, an evaluation of relevant ETD figures of merit, and the application of this instrument to protein sequence analysis. Described proteomic applications include complex peptide mixture analysis, post-translational modification (PTM) site identification, isotope-encoded quantitation, large peptide characterization, and intact protein analysis. From these experiments, we conclude the ETD-enabled orbitrap will provide the proteomic field with several new opportunities and represents an advance in protein sequence analysis technologies.


Assuntos
Proteômica/instrumentação , Espectrometria de Massas em Tandem/instrumentação , Sequência de Aminoácidos , Isótopos de Carbono , Linhagem Celular , Linhagem Celular Tumoral , Misturas Complexas/análise , Elétrons , Células-Tronco Embrionárias/química , Desenho de Equipamento , Fluorenos/química , Histonas/análise , Humanos , Íons , Marcação por Isótopo , Dados de Sequência Molecular , Fosfopeptídeos/análise , Proteínas de Saccharomyces cerevisiae/análise
14.
Anal Chem ; 80(11): 3985-90, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18465882

RESUMO

We describe the design and current performance of a 14.5 T hybrid linear quadrupole ion trap Fourier transform ion cyclotron resonance mass spectrometer. Ion masses are routinely determined at 4-fold better mass accuracy and 2-fold higher resolving power than similar 7 T systems at the same scan rate. The combination of high magnetic field and strict control of the number of trapped ions results in external calibration broadband mass accuracy typically less than 300 ppb rms, and a resolving power of 200,000 (m/Delta m50% at m/z 400) is achieved at greater than 1 mass spectrum per second. Novel ion storage optics and methodology increase the maximum number of ions that can be delivered to the FTICR cell, thereby improving dynamic range for tandem mass spectrometry and complex mixture applications.

15.
Nat Methods ; 4(9): 709-12, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17721543

RESUMO

Peptide sequencing is the basis of mass spectrometry-driven proteomics. Here we show that in the linear ion trap-orbitrap mass spectrometer (LTQ Orbitrap) peptide ions can be efficiently fragmented by high-accuracy and full-mass-range tandem mass spectrometry (MS/MS) via higher-energy C-trap dissociation (HCD). Immonium ions generated via HCD pinpoint modifications such as phosphotyrosine with very high confidence. Additionally we show that an added octopole collision cell facilitates de novo sequencing.


Assuntos
Espectrometria de Massas/métodos , Fragmentos de Peptídeos/química , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas/instrumentação , Conformação Proteica , Proteômica/instrumentação , Espectrometria de Massas em Tandem/instrumentação
16.
J Am Soc Mass Spectrom ; 17(7): 977-982, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16750636

RESUMO

Using a novel orbitrap mass spectrometer, the authors investigate the dynamic range over which accurate masses can be determined (extent of mass accuracy) for short duration experiments typical for LC/MS. A linear ion trap is used to selectively fill an intermediate ion storage device (C-trap) with ions of interest, following which the ensemble of ions is injected into an orbitrap mass analyzer and analyzed using image current detection and fast Fourier transformation. Using this technique, it is possible to generate ion populations with intraspectrum intensity ranges up to 10(4). All measurements (including ion accumulation and image current detection) were performed in less than 1 s at a resolving power of 30,000. It was shown that 5-ppm mass accuracy of the orbitrap mass analyzer is reached with >95% probability at a dynamic range of more than 5000, which is at least an order of magnitude higher than typical values for time-of-flight instruments. Due to the high resolving power of the orbitrap, accurate mass of an ion could be determined when the signal was reliably distinguished from noise (S/Np-p)>2...3).

17.
Anal Chem ; 78(7): 2113-20, 2006 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-16579588

RESUMO

Design and performance of a novel hybrid mass spectrometer is described. It couples a linear ion trap mass spectrometer to an orbitrap mass analyzer via an rf-only trapping quadrupole with a curved axis. The latter injects pulsed ion beams into a rapidly changing electric field in the orbitrap wherein they are trapped at high kinetic energies around an inner electrode. Image current detection is subsequently performed after a stable electrostatic field is achieved. Fourier transformation of the acquired transient allows wide mass range detection with high resolving power, mass accuracy, and dynamic range. The entire instrument operates in LC/MS mode (1 spectrum/s) with nominal mass resolving power of 60,000 and uses automatic gain control to provide high-accuracy mass measurements, within 2 ppm using internal standards and within 5 ppm with external calibration. The maximum resolving power exceeds 100,000 (fwhm). Rapid, automated data-dependent capabilities enable real-time acquisition of up to three high-mass accuracy MS/MS spectra per second.

18.
J Am Soc Mass Spectrom ; 17(12): 1758, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29500743

RESUMO

In the July issue, in the article, "Dynamic Range of Mass Accuracy in LTQ Orbitrap Hybrid Mass Spectrometer" by Alexander Makarov, Eduard Denisov, Oliver Lange, and Stevan Horning (Vol. 17, no. 7, pages 977-982), Figure 4 was printed in black and white, when it should have been published in color. The correct rendering of the figure, with its accompanying legend, is provided below.

19.
Rapid Commun Mass Spectrom ; 19(22): 3369-78, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16259046

RESUMO

Mass spectrometric identification and characterization of growth-promoting anabolic-androgenic steroids in biological matrices has been a major task for doping control as well as food safety laboratories. The fragmentation behavior of stanozolol, its metabolites 17-epistanozolol, 3'-OH-stanozolol, 4alpha-OH-stanozolol, 4beta-OH-stanozolol, 17-epi-16alpha-OH-stanozolol, 16alpha-OH-stanozolol, 16beta-OH-stanozolol, as well as the synthetic analogues 4-dehydrostanozolol, 17-ketostanozolol, and N-methyl-3'-OH-stanozolol, was investigated after positive electrospray ionization and subsequent collision-induced dissociation utilizing a quadrupole-linear ion trap and a novel linear ion trap-orbitrap hybrid mass spectrometer. Stable isotope labeling, H/D-exchange experiments, MS3 analyses and high-resolution/high mass accuracy measurements of fragment ions were employed to allow proposals for charge-driven as well as charge-remote fragmentation pathways generating characteristic product ions of stanozolol at m/z 81, 91, 95, 105, 119, 135 and 297 and 4-hydroxylated stanozolol at m/z 145. Fragment ions were generated by dissociation of the steroidal A- and B-ring retaining the introduced charge within the pyrazole function of stanozolol and by elimination of A- and B-ring fractions including the pyrazole residue. In addition, a charge-remote fragmentation causing the neutral loss of methanol was observed, which was suggested to be composed by the methyl residue at C-18 and the hydroxyl function located at C-17.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Estanozolol/análogos & derivados , Estanozolol/análise , Medição da Troca de Deutério , Íons , Estrutura Molecular , Estanozolol/química , Estanozolol/metabolismo , Relação Estrutura-Atividade
20.
Mol Cell Proteomics ; 4(12): 2010-21, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16249172

RESUMO

Mass accuracy is a key parameter of mass spectrometric performance. TOF instruments can reach low parts per million, and FT-ICR instruments are capable of even greater accuracy provided ion numbers are well controlled. Here we demonstrate sub-ppm mass accuracy on a linear ion trap coupled via a radio frequency-only storage trap (C-trap) to the orbitrap mass spectrometer (LTQ Orbitrap). Prior to acquisition of a spectrum, a background ion originating from ambient air is first transferred to the C-trap. Ions forming the MS or MS(n) spectrum are then added to this species, and all ions are injected into the orbitrap for analysis. Real time recalibration on the "lock mass" by corrections of mass shift removes mass error associated with calibration of the mass scale. The remaining mass error is mainly due to imperfect peaks caused by weak signals and is addressed by averaging the mass measurement over the LC peak, weighted by signal intensity. For peptide database searches in proteomics, we introduce a variable mass tolerance and achieve average absolute mass deviations of 0.48 ppm (standard deviation 0.38 ppm) and maximal deviations of less than 2 ppm. For tandem mass spectra we demonstrate similarly high mass accuracy and discuss its impact on database searching. High and routine mass accuracy in a compact instrument will dramatically improve certainty of peptide and small molecule identification.


Assuntos
Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Soroalbumina Bovina/química , Liofilização , Espectrometria de Massas/instrumentação , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS