Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Knee Surg ; 35(3): 323-330, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32659819

RESUMO

Posterior cruciate ligament (PCL) resection during posterior-stabilized total knee arthroplasty (PS-TKA) has been reported to preferentially increase the tibiofemoral joint gap in flexion compared with extension. However, previous assessments of the joint gaps have been performed after bone resection and medial soft tissue release. Thus, these procedural steps may have the potential to influence soft tissue balance. In native knees, soft tissue laxity is generally greater in the lateral compartment than in the medial compartment both with the knee in extension and in flexion. Some surgeons may retain this natural soft tissue balance with less aggressive medial release during TKA. We performed this study to evaluate the impact of the PCL resection on the extension and flexion gaps in the absence of bone resection or medial soft tissue release. Tibiofemoral joint gaps for 41 patients (10 males and 31 females) in full extension and at 90 degrees of flexion both before and after the resections of both the anterior cruciate ligament (ACL) and PCL were assessed using a ligament tensioner device. The statistical analyze was performed using the Mann-Whitney U test. The results showed that medial gap in extension and flexion were 6.7 ± 1.0 and 7.3 ± 0.9 mm, and lateral gap in extension and flexion were 7.6 ± 1.1 and 8.4 ± 1.6 mm, respectively. Thus, physiological tibiofemoral gaps just after knee arthrotomy were trapezoidal and asymmetric shape with the significantly wider gaps in lateral and flexion, compared with the medial and extension, respectively (p < 0.05). However, the increases of the gaps with the ACL and PCL resections were less than 1 mm under the existence of medial soft tissues. As the medial collateral ligament is the primary restraint for the valgus instability, it was also considered to prevent the increase of the flexion gap although the PCL-which is the secondary restraint for the valgus instability-was resected. This finding is critically important for orthopedic surgeons applying PS-TKA implants, particularly for preserving soft tissues to achieve natural knee kinematics postoperatively.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Ligamento Cruzado Posterior , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular
2.
Mol Ther Nucleic Acids ; 19: 199-207, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-31841992

RESUMO

Osteoarthritis (OA) is the most prevalent joint disorder associated with severe chronic pain. Although synovial inflammation is well correlated with pain severity, the molecular mechanism responsible for OA pain remains unclear. Here, we show that extracellular miR-21 released from synovial tissue mediates knee OA pain in surgical OA model rats. miR-21 was the most abundant among increased microRNAs (miRNAs) in the synovial tissue. miR-21 was released into extracellular space from the synovial tissue and increased in the synovial fluid. A single intra-articular injection of miR-21 inhibitor exerted long-term analgesia of knee OA pain, whereas miR-21 injection in naive rats caused knee joint pain. miR-21 mutant, which lacks the Toll-like receptor (TLR) binding motif, but not in the seed sequence, did not cause joint pain, suggesting a non-canonical mode of action different from translational repression. Consistent with this, the algesic effect of miR-21 was blocked by antagonizing TLR7. The TLR7 antagonist also exerted a long-lasting analgesic effect on knee OA pain. Therefore, extracellular miR-21 released from synovial tissue mediates knee OA pain through TLR7 activation in surgical OA model rats. Extracellular miRNA in the joint may be a plausible target for pain therapy, providing a novel analgesic strategy for OA.

3.
J Nippon Med Sch ; 83(5): 184-187, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27890891

RESUMO

Recent reports suggest that uncemented total hip replacement arthroplasty (THR) results in favorable short- to mid-term clinical results. In the present study, we assessed the mid-term clinical results of VerSys Hip System uncemented THR at our hospital. MATERIALS AND METHODS: We studied patients who received THR using VerSys Hip System and who could be followed-up more than 3 years. Clinical records were used to retrospectively identify patient characteristics, which included age, gender, disease requiring THR, preoperative and postoperative pain score of the Japan Orthopaedic Association scoring system, range of motion in flexion and abduction, operating time, intraoperative complication, and additional operation or revision surgery. Additionally, we investigated the loosening and alignment of implants from X-ray films. RESULTS: Ninety-one patients and 108 hip joints were investigated. Subjects were 11 males and 97 females (mean age, 64.6 years). Mean follow-up period was 6.9 years. Reasons for requiring THR were as follows: secondary osteoarthritis, 87 joints; idiopathic osteonecrosis of the femoral head, 16 joints; rapidly destructive coxarthrosis, 4 joints; and idiopathic ossification of the labrum, 1 joint. Mean operating time was 166 minutes. A total of 11 intraoperative fractures occurred, and wiring was performed in 3 of those cases. Adverse events pertaining to the surgery were limited; however, another adverse event was that 1 case resulted in intraoperative perforation of femoral cortex, for which a revision surgery was performed. There was no dislocation. Pain score using the Japan Orthopaedic Association scoring system and range of motion tests showed statistically significant improvement following THR. At the final follow-up, although no loosening of femoral implants was observed, the loosening of acetabular component was seen in 1 case. Varus insertion of femoral implant was recognized in 40 joints. Moreover, the average inclination angle of acetabular implants was 52.2 degrees. CONCLUSION: These data suggest that patients receiving VerSys Hip System uncemented THR demonstrate favorable results pertaining pain score and range of motion. However, high rate of intraoperative fracture and malalignment of implants, which may be at a risk of dislocation and/or polyethylene wear in future, suggests that this implant technique requires improvement.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos/farmacologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor
4.
J Nippon Med Sch ; 83(3): 113-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27430175

RESUMO

INTRODUCTION: We usually use short femoral nails for the treatment of trochanteric fracture of the femur. In this retrospective study, we investigated and compared the clinical results of the conventional intramedullary hip screw (IMHS) and the Asian IMHS, which is a redesigned version of the former. MATERIALS AND METHODS: The subjects were 42 patients; 21 treated with the Asian IMHS and 21 were treated with the conventional IMHS. From the clinical records, we retrospectively investigated the patients' age, sex, in-hospital waiting period for operation, operating time, intraoperative blood loss, walking ability before fracture and at discharge, and complication pertaining to the operation. RESULTS: The 21 patients (4 men and 17 women) receiving the Asian IMHS and the 21 patients (5 men and 16 women) receiving the conventional IMHS did not differ significantly in mean age, sex ratio, preoperative waiting period, mean postoperative hospital stay, mean operation time, or mean intraoperative blood loss. Among patients receiving the Asian IMHS, the complications of intraoperative fractures of the femur developed in 3 patients and breakage of the implant occurred in 1 patient. No complications occurred in patients receiving the conventional IMHS. DISCUSSION AND CONCLUSION: Compared with the conventional IMHS, the Asian IMHS is smaller, has increased variations in the shaft/neck angle of the lag screw, and has a titanium-alloy construction, allowing magnetic resonance imaging. The intraoperative fracture may have occurred because of the configuration of the distal interlocking screw in the Asian IMHS. Breakage of the implant likely occurred because the nail was too small in diameter, and too short in length for the unstable AO 31-A3 fracture. If careful attention is paid to the configuration of its distal interlocking screw intraoperatively and a nail of appropriate size is selected, the Asian IMHS is better suited than the conventional IMHS for treating Japanese patients, who generally have a small physique, because of its many variations in size and angle.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas , Fraturas do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Demografia , Feminino , Fraturas do Fêmur/complicações , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Quadril/complicações , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Cuidados Pré-Operatórios , Caminhada
5.
J Nippon Med Sch ; 83(6): 223-227, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28133002

RESUMO

BACKGROUND: The influence of varus insertion of femoral implants in uncemented total hip replacement arthroplasty (THR) remains unclear. Thus, in this study, we retrospectively assessed the clinical impact of uncemented THR with femoral implants that were inserted in varus on the basis of radiological findings. MATERIALS AND METHODS: The study participants included 89 patients who underwent uncemented THR for 106 joints and were followed-up for >3 years. From clinical records, we retrieved Japanese Orthopaedic Association (JOA) pain scores and the range of motion (ROM) of flexion and abduction both preoperatively and at the final follow-up. The presence of varus insertion of the femoral implant and stress shielding were also retrospectively reviewed from X-rays. We defined varus insertion of the femoral implant as the axis of the femoral implant that was inclined to the femoral shaft by 2° or more. Stress shielding was judged in accordance with Engh's classification system. RESULTS: Of the 106 joints, varus insertion was observed in 40 (37.3%) (the varus group) but not in 66 (62.3%) (the non-varus group). The JOA pain score significantly improved in both groups; however, there were no significant differences between the groups. Although ROM improved in both groups, there were no significant differences between the groups. The appearance rate of stress shielding of ≥third degree in the varus group was significantly greater than that in the non-varus group. CONCLUSION: These results revealed that varus insertion of femoral implants had no influence on short- to mid-term clinical outcomes because the pain score and ROM significantly improved in both the varus and non-varus groups. However, high rates of severe stress shielding appeared with varus insertion of femoral implants, suggesting an influence on long-term clinical outcomes.


Assuntos
Artroplastia de Quadril/métodos , Fêmur , Prótese de Quadril , Estresse Mecânico , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Medição da Dor , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...