Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Otol Neurotol ; 42(10): e1638-e1643, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267093

RESUMO

OBJECTIVES: Stapes surgery has evolved from its origins in 1956. Microscopic assisted stapedotomy remains the most common technique but the introduction of endoscopic ear surgery has led to some units using this new approach. The endoscope delivers a wide angled, contextual view of the stapes, and associated pathology. This systematic review provides a critical analysis of the current published endoscopic data, allowing comparison to the established microscopic technique. DATA SOURCES: Six databases (PubMed, Medline, Cochrane database, AMED, EMBASE, and CINAHL) were searched for studies within the last 10 years. STUDY SELECTION AND DATA EXTRACTION: English language articles including 5 or more cases were included. Primary outcomes included audiological results and reported complications. Data was extracted according to PRISMA guidelines. RESULTS: Thirteen papers were identified comprising 361 endoscopic stapes surgeries. Postoperative temporary facial nerve weakness was reported in 3 patients (0.8%) which all resolved within 4 weeks. Chorda tympani injury occurred in 21 cases (5.8%) and vertigo in 61 (16.9%). The audiometric outcomes of endoscopic stapes surgery were available for 259 patients and showed air bone gap closure rates of 71.4% (0-10 dB), 25.9% (11-20 dB), 2.3% (21-30 dB), and 0.4% (>30 dB). CONCLUSIONS: Endoscopic stapes surgery has similar audiometric outcomes compared to the traditional microscopic approach with air bone gap closure values of <20 dB in 97.3% of cases. However, the complication rates of chorda tympani damage, postoperative dysguesia, and tympanic membrane perforation for endoscopic stapes surgery are high. Caution should therefore be taken before undertaking stapes surgery with the endoscopic technique. Further studies are required to prove superiority over well established existing microsurgical methods.


Assuntos
Prótese Ossicular , Otosclerose , Cirurgia do Estribo , Endoscopia/efeitos adversos , Endoscopia/métodos , Humanos , Otosclerose/cirurgia , Estudos Retrospectivos , Estribo , Cirurgia do Estribo/efeitos adversos , Cirurgia do Estribo/métodos , Resultado do Tratamento
2.
Int J Pediatr Otorhinolaryngol ; 137: 110244, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32896356

RESUMO

OBJECTIVES: The Oticon™ wide implant system was launched in 2009 and used at Birmingham Children's Hospital from 2014. To evaluate clinical outcomes of the Oticon™ wide implant (Oticon Medical), with a focus on skin complication rates and fixture loss over a 5-year period in a tertiary paediatric hospital in the UK. METHODS: Retrospective 5-year longitudinal case record review of 47 children who were implanted with the Oticon™ wide implant system at Birmingham Children's Hospital (BCH) between January 2014 and January 2016. RESULTS: 47 children (27 M:20F) were implanted with 70 Oticon wide implants 23 bilateral, 27 unilateral. Mean age at the time of implantation was 9y 6 m. The follow up was for a mean of 5.4 years. Significant soft tissue complications requiring treatment was found in 11% (n = 8) of loaded fixtures, abutment tightening on two patients, abutment exchange 6% (n = 4) and a 10% (n = 7) fixture failure. CONCLUSION: The Oticon™ wide implant system produces favourable results with regards to peri-abutment skin complications, fixture stability and revision surgery rates when compared to similar cohorts of children studied at Birmingham Children's Hospital.


Assuntos
Auxiliares de Audição/efeitos adversos , Perda Auditiva/cirurgia , Complicações Pós-Operatórias/etiologia , Próteses e Implantes/efeitos adversos , Implantação de Prótese/instrumentação , Dermatopatias/etiologia , Adolescente , Criança , Pré-Escolar , Feminino , Hospitais Pediátricos , Humanos , Estudos Longitudinais , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Dermatopatias/diagnóstico , Dermatopatias/epidemiologia , Resultado do Tratamento
4.
J Vestib Res ; 28(3-4): 311-317, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30373968

RESUMO

BACKGROUND: Suppression Head Impulse Paradigm (SHIMP), a novel variant of the Head Impulse Test has been introduced. At the same time, the Head Impulse Test was renamed to the Head Impulse Paradigm (HIMP). Contrary to HIMP saccades, SHIMP saccades are a sign of vestibular function. OBJECTIVE: 1) To compare SHIMP and HIMP feasibility, vestibular-ocular reflex (VOR) gain value and the saccadic pattern in healthy adolescents. 2) To compare SHIMP and HIMP feasibility in the hands of an experienced and an inexperienced HIMP examiner. METHOD: A total of 29 adolescents from Skåde Municipal School, Denmark were tested with HIMP and then with SHIMP. RESULTS: Neither covert nor overt saccades were observed in the HIMP, whereas SHIMP saccades were observed in all SHIMP reports. SHIMP gain values were statistically lower than HIMP gain values. A statistically significant difference was observed between the two examiners' right SHIMP gain values, but not for the left SHIMP gain values or the HIMP gain values. CONCLUSIONS: We found that HIMP and SHIMP tests are feasible in healthy adolescents for experienced as well as inexperienced examiners. However, one must be aware of potential pitfalls in the execution and interpretation of both tests. This is a well-known fact for the HIMP test, but additional considerations are needed to obtain reliable results from the SHIMP test.


Assuntos
Teste do Impulso da Cabeça/métodos , Adolescente , Feminino , Humanos , Masculino , Reflexo Vestíbulo-Ocular/fisiologia , Movimentos Sacádicos/fisiologia
6.
Cochlear Implants Int ; 18(4): 192-197, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28534710

RESUMO

INTRODUCTION: Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. METHODS: A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. RESULTS: Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. CONCLUSIONS: Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.


Assuntos
Cóclea/lesões , Implante Coclear/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Adulto , Membrana Basilar/diagnóstico por imagem , Membrana Basilar/patologia , Membrana Basilar/cirurgia , Cóclea/diagnóstico por imagem , Cóclea/patologia , Implantes Cocleares/efeitos adversos , Feminino , Perda Auditiva/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Radiografia/métodos , Rampa do Tímpano/diagnóstico por imagem , Rampa do Tímpano/patologia , Rampa do Tímpano/cirurgia , Osso Temporal/diagnóstico por imagem , Osso Temporal/patologia , Osso Temporal/cirurgia
7.
BMJ Case Rep ; 20152015 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-25631761

RESUMO

We present a case of unusual presentation of stridor in an adult man who was identified to have a sudden expansion of a foregut duplication cyst in the mediastinum. This resulted in superior vena caval obstruction and subsequent airway compromise. Following resuscitation, the cyst was surgically removed via a thoracotomy which confirmed the diagnosis and provided definitive management. Foregut duplication cysts are an unusual cause of stridor in adults, with only five cases ever documented worldwide in the literature, presenting in such a manner. This case is a reminder of the importance of thorough clinical examination, the benefits of radiology as an indispensible adjunct and essential role of the multidisciplinary team.


Assuntos
Cisto Mediastínico/complicações , Sons Respiratórios/etiologia , Humanos , Masculino , Cisto Mediastínico/congênito , Cisto Mediastínico/cirurgia , Pessoa de Meia-Idade , Transtornos Respiratórios/etiologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...