Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 24(6): 600-5, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19795364

RESUMO

A simple and sensitive method that dose not require derivatization for determining cholestanol has been developed using HPLC with electrochemical detection (HPLC-ECD). The current peak height was linearly related to the amount of cholestanol injected, ranging from 1 to 200 muM (r = 0.999). The detection limit (S/N = 3) of cholestanol was 0.23 muM (1.2 pmol). Total cholestanol in control human and mouse serum was determined by the present method with a recovery rate of more than 90% and an RSD (n = 5) of less than 7.3%. Further, this method was successfully applied to monitor experimental hypercholestanolemia in mice fed a high-cholestanol diet, an animal model of cerebrotendinous xanthomatosis (CTX). In conclusion, we found this method to be both simple and useful for the determination of cholestanol in serum, helping in the diagnosis of CTX.


Assuntos
Colestanol/sangue , Cromatografia Líquida de Alta Pressão/métodos , Animais , Cromatografia Líquida de Alta Pressão/instrumentação , Eletroquímica , Humanos , Limite de Detecção , Masculino , Camundongos , Camundongos Endogâmicos BALB C
2.
J Chromatogr A ; 1166(1-2): 135-41, 2007 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-17723233

RESUMO

A simple and sensitive HPLC method that does not require derivatization for determining cholesterol has been developed. Investigation of voltammetric behavior of cholesterol showed that cholesterol could be oxidized on a glassy carbon electrode in non-aqueous solvents. This was applied to the development of a method by HPLC with electrochemical detection (HPLC-ED). The HPLC-ED was optimized using the separation of cholesterol and oxysterols including 26-hydroxycholesterol and 24S-hydroxycholesterol. The separation was carried out with a Develosil C30-UG-3 column; acetonitrile-2-propanol (9:1, v/v) containing 50mM LiClO(4) as a mobile phase; and an applied potential at 1.9V versus Ag/AgCl. The current peak height was linearly related to the amount of cholesterol injected from 0.5-100 microM (r>0.999). The detection limit (S/N=3) of cholesterol was 0.36 microM (1.8 pmol). Cholesterol at 100 microM was directly detected with a relative standard deviation (RSD) of less than 1.0% (n=8). Total cholesterol and free cholesterol in control human serum were determined by the present method with the recovery of more than 90% and the RSD (n=6) of less than 3.0%.


Assuntos
Colesterol/sangue , Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...