Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Biomedicines ; 11(2)2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36830814

RESUMO

MicroRNA (miRNA) is a short (19-24 nucleotide) endogenous non-protein RNA that exists in the body and controls the translation process from genes to proteins. It has become useful as a diagnostic tool and a potential treatment target in cancer research. To explore the function of miRNA in contact dermatitis, female participants with a positive metal allergy diagnosis (n = 3) were enrolled along with additional female participants with no medical history of metal allergy (n = 3). A patch test was performed on each participant. Peripheral blood was collected from all the participants before the patch test and at days 3 and 7 after starting the patch test. After total RNA was obtained from peripheral blood leukocytes and cDNA was generated, microarray analysis was performed to analyze the large-scale circulating miRNA profile. Real-time polymerase chain reaction (RT-PCR) was then used to clarify the overall target miRNA expression. Downregulation of hsa-let-7d-5p, hsa-miR-24-3p, hsa-miR-23b-3p, hsa-miR-26b-5p, and hsa-miR-150-5p was found on day 7. Certain miRNAs were confirmed using RT-PCR. These peripheral blood miRNAs could be diagnostic biomarkers for metal allergies.

2.
Int J Mol Sci ; 20(3)2019 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-30736422

RESUMO

Neuron-glia interactions contribute to pain initiation and sustainment. Intra-ganglionic (IG) secretion of calcitonin gene-related peptide (CGRP) in the trigeminal ganglion (TG) modulates pain transmission through neuron-glia signaling, contributing to various orofacial pain conditions. The present study aimed to investigate the role of satellite glial cells (SGC) in TG in causing cytokine-related orofacial nociception in response to IG administration of CGRP. For that purpose, CGRP alone (10 µL of 10-5 M), Minocycline (5 µL containing 10 µg) followed by CGRP with one hour gap (Min + CGRP) were administered directly inside the TG in independent experiments. Rats were evaluated for thermal hyperalgesia at 6 and 24 h post-injection using an operant orofacial pain assessment device (OPAD) at three temperatures (37, 45 and 10 °C). Quantitative real-time PCR was performed to evaluate the mRNA expression of IL-1ß, IL-6, TNF-α, IL-1 receptor antagonist (IL-1RA), sodium channel 1.7 (NaV 1.7, for assessment of neuronal activation) and glial fibrillary acidic protein (GFAP, a marker of glial activation). The cytokines released in culture media from purified glial cells were evaluated using antibody cytokine array. IG CGRP caused heat hyperalgesia between 6⁻24 h (paired-t test, p < 0.05). Between 1 to 6 h the mRNA and protein expressions of GFAP was increased in parallel with an increase in the mRNA expression of pro-inflammatory cytokines IL-1ß and anti-inflammatory cytokine IL-1RA and NaV1.7 (one-way ANOVA followed by Dunnett's post hoc test, p < 0.05). To investigate whether glial inhibition is useful to prevent nociception symptoms, Minocycline (glial inhibitor) was administered IG 1 h before CGRP injection. Minocycline reversed CGRP-induced thermal nociception, glial activity, and down-regulated IL-1ß and IL-6 cytokines significantly at 6 h (t-test, p < 0.05). Purified glial cells in culture showed an increase in release of 20 cytokines after stimulation with CGRP. Our findings demonstrate that SGCs in the sensory ganglia contribute to the occurrence of pain via cytokine expression and that glial inhibition can effectively control the development of nociception.


Assuntos
Citocinas/metabolismo , Dor Facial/metabolismo , Neuroglia/metabolismo , Nociceptividade , Receptores de Peptídeo Relacionado com o Gene de Calcitonina/metabolismo , Gânglio Trigeminal/citologia , Gânglio Trigeminal/metabolismo , Animais , Modelos Animais de Doenças , Dor Facial/genética , Hiperalgesia/genética , Hiperalgesia/metabolismo , Hiperalgesia/fisiopatologia , Masculino , Modelos Biológicos , Neurônios/metabolismo , Ratos , Temperatura
3.
Clin Case Rep ; 6(10): 1972-1977, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30349710

RESUMO

Patch testing with metal reagents was positive on female patient with history of metal hypersensitivity after dental treatment. All of the dental restorations with metal components were removed, and subsequent oral rehabilitation utilizing dental implants and metal-free prostheses was carried out. The treatments alleviate the presenting signs and symptoms.

4.
J Prosthodont Res ; 62(4): 426-431, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29673741

RESUMO

PURPOSE: Studies have reported cases of metal allergy caused by titanium-containing materials. We wished to clarify the relationship between titanium allergy and dental implants by describing patients who suffered allergic symptoms after they had received such implants. METHODS: A total of 270 patients who visited a Dental Metal Allergy Clinic at Tokushima University Hospital from April 2010 to March 2014 were the study cohort. Patch testing with 28 types of metal allergens (including four titanium allergens) was undertaken for patients. RESULTS: A total of 217 patients (80.4 %) exhibited allergy-positive reactions to at least one type of metal allergen. Mercury, palladium, chromium and nickel exhibited a higher prevalence of allergy-positive reactions than other metals. Sixteen patients visited our clinic suffering allergic symptoms after receiving dental implants. Eleven of those patients exhibited allergy-positive reactions for any of the metal allergens, and 4 of these patients had allergy-positive reactions against titanium allergens. The total number of allergy-positive reactions for titanium allergens among all 270 patients was 17 (6.3 %). No patient exhibited a positive reaction only for the titanium allergen. CONCLUSIONS: The prevalence of allergy-positive reactions for titanium allergens was lower than for other metal allergens. We suggest examination of pre-implant patients who have a history of hypersensitivity reactions to metals.


Assuntos
Implantes Dentários/efeitos adversos , Materiais Dentários/efeitos adversos , Hipersensibilidade/etiologia , Titânio/efeitos adversos , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Hipersensibilidade/epidemiologia , Hipersensibilidade/prevenção & controle , Masculino , Testes do Emplastro , Prevalência , Risco
5.
J Dent Educ ; 81(12): 1451-1456, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29196333

RESUMO

The aim of this study was to determine the validity of peer evaluation for team-based learning (TBL) classes in dental education in comparison with the term-end examination records and TBL class scores. Examination and TBL class records of 256 third- and fourth-year dental students in six fixed prosthodontics courses from 2013 to 2015 in one dental school in Japan were investigated. Results of the term-end examination during those courses, individual readiness assurance test (IRAT), group readiness assurance test (GRAT), group assignment projects (GAP), and peer evaluation of group members in TBL classes were collected. Significant positive correlations were found between all combinations of peer evaluation, IRAT, and term-end examination. Individual scores also showed a positive correlation with group score (total of GRAT and GAP). From the investigation of the correlations in the six courses, significant positive correlations between peer evaluation and individual score were found in four of the six courses. In this study, peer evaluation seemed to be a valid index for learning performance in TBL classes. To verify the effectiveness of peer evaluation, all students have to realize the significance of scoring the team member's performance. Clear criteria and detailed instruction for appropriate evaluation are also required.


Assuntos
Educação em Odontologia/métodos , Avaliação Educacional/métodos , Grupo Associado , Processos Grupais , Humanos , Japão , Aprendizagem , Reprodutibilidade dos Testes , Faculdades de Odontologia , Ensino
6.
J Prosthodont Res ; 61(2): 217-222, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27185191

RESUMO

PURPOSE: We previously investigated the effects of team-based learning (TBL) on fixed prosthodontic education and reported that TBL could have higher efficiency with high student satisfaction than traditional lecture. In the current report, we introduced flipped classroom to the fixed prosthodontic education and compared their effectiveness based on the final examination score in addition to TBL. METHODS: Participants were 41 students from Tokushima University School of Dentistry who attended a fixed prosthodontics course. The first six classes adopted the flipped classroom style while the latter eight classes adopted TBL. To evaluate the relationship between learning styles and their effectiveness, we compared results from the term-end examination between the curriculum covered by flipped classroom and TBL-style classes. To draw comparisons, a referential examination with the same questions was conducted to eight faculty members who had not attended any of these classes. RESULTS: Term-end examination results showed that TBL classes had slightly higher scores than flipped classroom classes. Referential examination results also showed higher scores for the same curriculum and no significant interaction was found between class formats and the term-end and referential examination scores. Analysis revealed no noticeable difference in the effectiveness of the class formats. CONCLUSION: Our previous study reported that TBL had higher efficiency than traditional style lecture. In the current study, there was no statistical difference in the examination score between flipped classroom and TBL. Therefore, we conclude that both styles are highly effective than traditional style lecture and constitute valid formats for clinical dental education.


Assuntos
Educação em Odontologia/métodos , Aprendizagem , Prostodontia/educação , Estudantes de Odontologia/psicologia , Testes de Aptidão , Feminino , Humanos , Japão , Masculino , Satisfação Pessoal , Faculdades de Odontologia
7.
J Prosthodont Res ; 60(3): 213-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26774509

RESUMO

PATIENTS: Titanium has been considered to be a non-allergenic material. However, several studies have reported cases of metal allergy caused by titanium-containing materials. We describe a 69-year-old male for whom significant pathologic findings around dental implants had never been observed. He exhibited allergic symptoms (eczema) after orthopedic surgery. The titanium screws used in the orthopedic surgery that he underwent were removed 1 year later, but the eczema remained. After removal of dental implants, the eczema disappeared completely. DISCUSSION: Titanium is used not only for medical applications such as plastic surgery and/or dental implants, but also for paints, white pigments, photocatalysts, and various types of everyday goods. Most of the usage of titanium is in the form of titanium dioxide. This rapid expansion of titanium-containing products has increased percutaneous and permucosal exposure of titanium to the population. CONCLUSIONS: In general, allergic risk of titanium material is smaller than that of other metal materials. However, we suggest that pre-implant patients should be asked about a history of hypersensitivity reactions to metals, and patch testing should be recommended to patients who have experienced such reactions.


Assuntos
Parafusos Ósseos/efeitos adversos , Implantes Dentários/efeitos adversos , Materiais Dentários/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Titânio/efeitos adversos , Idoso , Dermatite Alérgica de Contato/patologia , Dermatite Alérgica de Contato/terapia , Remoção de Dispositivo , Humanos , Masculino , Procedimentos Ortopédicos
8.
J Dent Educ ; 79(4): 417-23, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25838013

RESUMO

The aims of this study were to evaluate the quality of team-based learning (TBL) in prosthodontics education for fourth-year dental students at Tokushima University School of Dentistry and to compare this teaching method with traditional lecture-based delivery. Participants in the study were 36 students (22 males and 14 females) who attended the TBL-style fixed prosthodontics course. Ten 60-minute classes were held. The first three were traditional lecture-style classes and were followed by one class introducing the TBL style. The remaining six classes constituted the TBL-format fixed prosthodontics course. The effectiveness of TBL was evaluated through student questionnaires at the end of each class and the results of the term-end examination. The questionnaire revealed high student approval for TBL-style learning, and active group discussion among students during TBL was a key factor in these ratings. In the results of the term-end examination, there were significantly higher scores on the questions that covered TBL-taught material than those covering traditional lecture-taught topics. The results of this study suggest that TBL-style lecture was more effective than traditional-style lecture for teaching fixed prosthodontics and that TBL was a more efficient mode of delivering dental education than traditional lecture-based teaching.


Assuntos
Educação em Odontologia , Processos Grupais , Aprendizagem , Prostodontia/educação , Estudantes de Odontologia/psicologia , Ensino/métodos , Atitude do Pessoal de Saúde , Comportamento Cooperativo , Avaliação Educacional , Retroalimentação , Feminino , Humanos , Japão , Masculino , Aprendizagem Baseada em Problemas , Inquéritos e Questionários
9.
J Prosthodont Res ; 58(2): 71-84, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24746524

RESUMO

This position paper reviews physical and mechanical properties of thermoplastic resin used for non-metal clasp dentures, and describes feature of each thermoplastic resin in clinical application of non-metal clasp dentures and complications based on clinical experience of expert panels. Since products of thermoplastic resin have great variability in physical and mechanical properties, clinicians should utilize them with careful consideration of the specific properties of each product. In general, thermoplastic resin has lower color-stability and higher risk for fracture than polymethyl methacrylate. Additionally, the surface of thermoplastic resin becomes roughened more easily than polymethyl methacrylate. Studies related to material properties of thermoplastic resin, treatment efficacy and follow-up are insufficient to provide definitive conclusions at this time. Therefore, this position paper should be revised based on future studies and a clinical guideline should be provided.


Assuntos
Materiais Dentários , Prótese Parcial Removível , Resinas Sintéticas , Resinas Acrílicas , Humanos , Fenômenos Mecânicos , Metais , Nylons , Fenômenos Físicos , Cimento de Policarboxilato , Poliésteres , Polímeros , Polimetil Metacrilato , Polipropilenos , Sulfonas
10.
J Prosthodont Res ; 58(1): 3-10, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24461323

RESUMO

This position paper proposes a definition and naming standard for removable partial dentures (RPDs) using thermoplastic resin, and presents a guideline for clinical application. A panel of 14 experts having broad experience with clinical application of RPDs using thermoplastic resin was selected from members of the Japan Prosthodontic Society. At a meeting of the panel, "non-metal clasp denture" was referred as the generic name of RPDs with retentive elements (resin clasps) made of thermoplastic resin. The panel classified non-metal clasp dentures into two types: one with a flexible structure that lacks a metal framework and the other having a rigid structure that includes a metal framework. According to current prosthetic principles, flexible non-metal clasp dentures are not recommended as definitive dentures, except for limited cases such as patients with a metal allergy. Rigid non-metal clasp dentures are recommended in cases where patients will not accept metal clasps for esthetic reasons. Non-metal clasp dentures should follow the same design principles as conventional RPDs using metal clasps.


Assuntos
Grampos Dentários , Planejamento de Dentadura , Prótese Parcial Removível , Resinas Sintéticas , Contraindicações , Retenção de Dentadura , Humanos , Metais/efeitos adversos
11.
Biomed Mater Eng ; 19(1): 53-61, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19458446

RESUMO

Some metallic materials in dental prostheses may cause allergic hypersensitivity. Symptoms appear not only in the oral cavity, but also on hands, feet or the entire body. Release of metal ions is thought to cause the allergic reactions; micro-particles of the corrosion products of the metal and/or ionic metal hydroxides/oxides may be the allergens. The study purpose was to review clinical surveillance of dental allergic hypersensitivity in our dental hospital. From July 2000 to June 2005, 212 patients with suspected dental metal allergy were patch tested with 26 reagents, including 19 ready-made patch test reagents (Patch test reagents, Torii Pharmaceutical Corporation, Tokyo, Japan) and 9 custom-made reagents. One-hundred-and-sixty-seven patients were females (78.8%) and 45 patients were males (21.2%). A total of 148 patients (69.8%) had one or more positive patch test reactions. The most common allergens were nickel (25.0%), palladium (24.4%), chromium (16.7%), cobalt (15.9%) and stannum (12.5%). Typical allergic symptoms and diagnoses were Pustulosis palmaris et plantaris, lichen planus, stomatitis and contact dermatitis. This study indicates that dentists and dental researchers should be concerned about the allergenic potential of dental metal materials.


Assuntos
Materiais Dentários/efeitos adversos , Dermatite de Contato/diagnóstico , Dermatite de Contato/etiologia , Testes do Emplastro , Feminino , Humanos , Masculino , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...