1.
Front Rehabil Sci ; 5: 1354115, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38994331

RESUMO

Introduction: A concern expressed by the clinical community is that the constraint of motion provided by an ankle foot orthosis (AFO) may lead the user to become dependent on its stiffness, leading to learned non-use. To examine this, we hypothesized that using an experimental AFO-footwear combination (exAFO-FC) that constrains ankle motion during walking would result in reduced soleus and tibialis anterior EMG compared to free (exAFO-FC) and control (no AFO, footwear only) conditions. Method: A total of 14 healthy subjects walked at their preferred speed (1.34 ± 0.09 m·s-1) for 15 min, in three conditions, namely, control, free, and stop. Results: During the stance phase of walking in the stop condition, ipsilateral soleus integrated EMG (iEMG) declined linearly, culminating in a 32.1% reduction compared to the control condition in the final 5 min interval of the protocol. In contrast, ipsilateral tibialis anterior iEMG declined in a variable fashion culminating in an 11.2% reduction compared to control in the final 5 min interval. During the swing phase, the tibialis anterior iEMG increased by 6.6% compared to the control condition during the final 5 min interval. The contralateral soleus and tibialis anterior exhibited increased iEMG in the stop condition. Discussion: An AFO-FC functions as a biomechanical motion control device that influences the neural control system and alters the output of muscles experiencing constraints of motion.

2.
Clin Biomech (Bristol, Avon) ; 82: 105285, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33548768

RESUMO

BACKGROUND: This study, the first of its kind, originated with the need for a brace (an ankle foot orthosis), to constrain ankle plantarflexion and dorsiflexion within a motion threshold of <5°. A conventional thermoplastic, solid brace failed during a quasi-static loading study, informing the investigation and development of an experimental carbon composite brace, maximizing stiffness and proximity of shank and foot cylindrical shells to provide the required degree of control. METHODS: Two experiments were conducted: a quasi-static loading study, using cadaveric limbs (n = 2), and a gait study with healthy subjects (n = 14). Conditions tested were STOP, FREE, and CONTROL. Data for all studies were collected using six motion-capture cameras (Vicon, Oxford, UK; 120 Hz) tracking bone-anchored markers (cadaveric limbs) and skin-anchored markers (subjects). In the quasi-static loading study, loading conditions were congruent with the gait study. Study 1 involved a quasi-static loading analysis using cadaveric limbs, compared motion data from a conventional thermoplastic solid brace and the experimental brace. Study 2 involved quantifying ankle plantarflexion and dorsiflexion in subjects during treadmill walking, in brace STOP, FREE, and CONTROL conditions. FINDINGS: The experimental brace in STOP condition consistently constrained ankle plantarflexion and dorsiflexion below the motion threshold of <5°, across all studies. INTERPRETATION: Collectively, these findings demonstrate (1) that a conventional thermoplastic, solid brace was ineffective for clinical applications that required significant motion control, and (2) that ankle motion control is most effective when considered as a relationship between the brace, the ankle-foot complex, and the external forces that affect them both.


Assuntos
Tornozelo , Órtoses do Pé , Fenômenos Mecânicos , Movimento , Adulto , Tornozelo/fisiologia , Fenômenos Biomecânicos , Braquetes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...