Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Pathol Inform ; 7: 7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26955505

RESUMO

BACKGROUND: Epic Beaker Clinical Pathology (CP) is a relatively new laboratory information system (LIS) operating within the Epic suite of software applications. To date, there have not been any publications describing implementation of Beaker CP. In this report, we describe our experience in implementing Beaker CP version 2012 at a state academic medical center with a go-live of August 2014 and a subsequent upgrade to Beaker version 2014 in May 2015. The implementation of Beaker CP was concurrent with implementations of Epic modules for revenue cycle, patient scheduling, and patient registration. METHODS: Our analysis covers approximately 3 years of time (2 years preimplementation of Beaker CP and roughly 1 year after) using data summarized from pre- and post-implementation meetings, debriefings, and the closure document for the project. RESULTS: We summarize positive aspects of, and key factors leading to, a successful implementation of Beaker CP. The early inclusion of subject matter experts in the design and validation of Beaker workflows was very helpful. Since Beaker CP does not directly interface with laboratory instrumentation, the clinical laboratories spent extensive preimplementation effort establishing middleware interfaces. Immediate challenges postimplementation included bar code scanning and nursing adaptation to Beaker CP specimen collection. The most substantial changes in laboratory workflow occurred with microbiology orders. This posed a considerable challenge with microbiology orders from the operating rooms and required intensive interventions in the weeks following go-live. In postimplementation surveys, pathology staff, informatics staff, and end-users expressed satisfaction with the new LIS. CONCLUSIONS: Beaker CP can serve as an effective LIS for an academic medical center. Careful planning and preparation aid the transition to this LIS.

2.
Clin Infect Dis ; 56(5): 641-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23150211

RESUMO

Background. The occurrence of community-associated infections due to extended-spectrum ß-lactamase (ESBL)-producing Escherichia coli has been recognized as a major clinical problem in Europe and other regions. Methods. We conducted a prospective observational study to examine the occurrence of community-associated infections due to ESBL-producing E. coli at centers in the United States. Five academic and community hospitals and their affiliated clinics participated in this study in 2009 and 2010. Sites of acquisition of the organisms (community-associated or healthcare-associated), risk factors, and clinical outcome were investigated. Screening for the global epidemic sequence type (ST) 131 and determination of the ESBL types was conducted by polymerase chain reaction and sequencing. Results. Of the 291 patients infected or colonized with ESBL-producing E. coli as outpatients or within 48 hours of hospitalization, 107 (36.8%) had community-associated infection (81.5% of which represented urinary tract infection), while the remainder had healthcare-associated infection. Independent risk factors for healthcare-associated infection over community-associated infection were the presence of cardiovascular disease, chronic renal failure, dementia, solid organ malignancy, and hospitalization within the previous 12 months. Of the community-associated infections, 54.2% were caused by the globally epidemic ST131 strain, and 91.3% of the isolates produced CTX-M-type ESBL. Conclusions. A substantial portion of community-onset, ESBL-producing E. coli infections now occur among patients without discernible healthcare-associated risk factors in the United States. This epidemiologic shift has implications for the empiric management of community-associated infection when involvement of E. coli is suspected.


Assuntos
Infecções Comunitárias Adquiridas/epidemiologia , Infecções por Escherichia coli/epidemiologia , Escherichia coli/enzimologia , beta-Lactamases/metabolismo , Infecções Comunitárias Adquiridas/microbiologia , Infecções por Escherichia coli/microbiologia , Humanos , Estudos Prospectivos , Fatores de Risco , Estados Unidos/epidemiologia
3.
J Clin Microbiol ; 50(6): 2034-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22495566

RESUMO

The Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) instruments were evaluated for the identification of nonfermenting gram-negative bacilli (NFGNB) by a blinded comparison to conventional biochemical or molecular methods. Two hundred NFGNB that were recovered from cultures from cystic fibrosis patients in the University of Iowa Health Care (UIHC) Microbiology Laboratory between 1 January 2006 and 31 October 2010 were sent to Mayo Clinic for analysis with the Bruker Biotyper (software version 3.0) and to bioMérieux for testing with Vitek MS (SARAMIS database version 3.62). If two attempts at direct colony testing failed to provide an acceptable MALDI-TOF identification, an extraction procedure was performed. The MS identifications from both of these systems were provided to UIHC for comparison to the biochemical or molecular identification that had been reported in the patient record. Isolates with discordant results were analyzed by 16S rRNA gene sequencing at UIHC. After discrepancy testing, the Bruker Biotyper result agreed with the biochemical or molecular method, with 72.5% of isolates to the species level, 5.5% to the complex level, and 19% to the genus level (3% not identified). The level of agreement for Vitek MS was 80% species, 3.5% complex, 6% genus, and 3.5% family (7% not identified). Both MS systems provided rapid (≤3 min per isolate) and reliable identifications. The agreement of combined species/complex/genus-level identification with the reference method was higher for the Bruker Biotyper (97% versus 89.5%, P = 0.004) but required an extraction step more often. Species-level agreement with the reference method was similar for both MS systems (72.5% and 80%, P = 0.099).


Assuntos
Técnicas Bacteriológicas/métodos , Fibrose Cística/complicações , Bactérias Gram-Negativas/classificação , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/diagnóstico , Infecções por Bactérias Gram-Negativas/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias Aeróbias/química , Bactérias Aeróbias/classificação , Bactérias Aeróbias/isolamento & purificação , Bactérias Aeróbias/metabolismo , Bactérias Gram-Negativas/química , Bactérias Gram-Negativas/metabolismo , Humanos , Iowa , Sensibilidade e Especificidade , Fatores de Tempo
4.
J Clin Microbiol ; 49(8): 2996-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21677066

RESUMO

Methicillin-susceptible Staphylococcus aureus (MSSA) isolates lacking mecA yet testing positive on the Xpert MRSA assay were recovered from culture for 7.7% of 248 Xpert-positive nasal samples. These "false-positive" Xpert results may be attributed to staphylococcal cassette chromosome (SCC) elements without the mecA gene. Pulsed-field gel electrophoresis (PFGE) analysis revealed a diverse population of MSSA strains.


Assuntos
Antibacterianos/farmacologia , Técnicas Bacteriológicas/métodos , Erros de Diagnóstico , Meticilina/farmacologia , Técnicas de Diagnóstico Molecular/métodos , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/efeitos dos fármacos , Proteínas de Bactérias/genética , DNA Bacteriano/genética , Humanos , Proteínas de Ligação às Penicilinas , Staphylococcus aureus/isolamento & purificação
5.
J Clin Microbiol ; 48(5): 1929-31, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20220158

RESUMO

The BD Phoenix AP instrument reduced the manual setup time for the Phoenix system by 50%. For batches of 14 organisms, the average manual manipulation time per isolate was 89.5 s for BD Phoenix by the use of the AP instrument and 101 s for Vitek 2 (P<0.001).


Assuntos
Infecções Bacterianas/diagnóstico , Técnicas de Tipagem Bacteriana/métodos , Fluxo de Trabalho , Infecções Bacterianas/microbiologia , Humanos , Fatores de Tempo
6.
J Clin Microbiol ; 45(9): 2863-71, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17652483

RESUMO

This multicenter study evaluated the BD Phoenix Automated Microbiology System STREP panel (BD Diagnostic Systems). Antimicrobial susceptibility testing (AST) with 13 agents was performed on 2,013 streptococci (938 Streptococcus pneumoniae isolates; 396 group B streptococci [GBS]; 369 viridans group streptococci [VGS]; 290 beta-hemolytic streptococcus groups A, C, and G; and 20 other streptococci) with the Phoenix system and a broth microdilution reference method. Clinical and challenge isolates were tested against cefepime, cefotaxime (CTX), ceftriaxone (CTR), clindamycin (CLI), erythromycin (ERY), gatifloxacin, levofloxacin, linezolid, meropenem, penicillin (PEN), tetracycline (TET), trimethoprim-sulfamethoxazole, and vancomycin. Clinical isolates with major errors or very major errors (VMEs) were retested in duplicate by both methods. The final results for clinical isolates showed the following trends. For all of the organism-antimicrobial agent combinations tested, categorical agreement (CA) was 92 to 100%, with one exception-VGS-PEN (87% CA; all errors were minor). For S. pneumoniae, there was one major error with CLI (0.1%) and one or two VMEs with CTX (4%), CTR (4.5%), ERY (0.9%), and TET (0.7%). For groups A, C, and G, the CA was 97 to 100% and the only VMEs were resolved by additional reference laboratory testing. For GBS, there was only one VME (TET, 0.3%) and D-zone testing of 23 isolates with CLI major errors (one isolate unavailable) revealed inducible CLI resistance. For VGS, the major error rates were 0 to 3% and VMEs occurred with seven agents (3.5 to 7.1%). The mean times required for organism groups to generate results ranged from 8.4 to 9.4 h. The Phoenix system provided reliable and rapid AST results for most of the organism-antimicrobial agent combinations tested.


Assuntos
Antibacterianos/farmacologia , Testes de Sensibilidade Microbiana/métodos , Streptococcus/efeitos dos fármacos , Erros de Diagnóstico , Combinação de Medicamentos , Farmacorresistência Bacteriana , Humanos , Reprodutibilidade dos Testes , Infecções Estreptocócicas/microbiologia
7.
J Clin Microbiol ; 43(11): 5536-40, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16272482

RESUMO

Active surveillance for methicillin-resistant Staphylococcus aureus (MRSA) is among the strategies recommended by the Society for Healthcare Epidemiology of America for control of nosocomial MRSA infections. Infection control and laboratory personnel desire rapid, sensitive, and inexpensive methods to enhance surveillance activities. A multicenter study was performed to evaluate a new selective and differential chromogenic medium, BBL CHROMagar MRSA (C-MRSA) medium (BD Diagnostics, Sparks, MD), which enables recovery and concomitant identification of MRSA strains directly from nasal swab specimens taken from the anterior nares. Specimens were inoculated to C-MRSA and Trypticase soy agar with 5% sheep blood agar (TSA II, BD Diagnostics). Mauve colonies on C-MRSA at 24 h and 48 h and suspicious colonies on TSA II were confirmed as Staphylococcus aureus by Gram stain morphology and a coagulase test. In addition, the results of C-MRSA were compared to results of susceptibility testing (five different methods) of S. aureus strains isolated on TSA II. A total of 2,015 specimens were inoculated to C-MRSA and TSA II. Three hundred fifty-four S. aureus isolates were recovered; 208 (59%) were oxacillin (methicillin) susceptible and 146 (41%) were oxacillin resistant (MRSA). On C-MRSA, 139/146 or 95.2% of MRSA isolates were recovered, whereas recovery on TSA II was 86.9% (127/146) (P = 0.0027). The overall specificity of C-MRSA was 99.7%. When C-MRSA was compared to each susceptibility testing method, the sensitivity and specificity, respectively, were as follows: oxacillin MIC by broth microdilution, 94.4% and 96.7%; oxacillin screen agar, 94.3% and 96.7%; PBP2' latex agglutination, 93.7% and 98.5%; cefoxitin disk diffusion, 95.0% and 98.1%; and mecA PCR, 95.1% and 98.1%. In this study, C-MRSA was superior to TSA II for recovery of MRSA from surveillance specimens obtained from the anterior nares and was comparable to conventional, rapid, and molecular susceptibility methods for the identification of MRSA isolates.


Assuntos
Antibacterianos/farmacologia , Meticilina/farmacologia , Mucosa Nasal/microbiologia , Infecções Estafilocócicas/diagnóstico , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/isolamento & purificação , Ágar , Compostos Cromogênicos , Infecção Hospitalar/prevenção & controle , Meios de Cultura , Humanos , Resistência a Meticilina , Oxacilina/farmacologia , Sensibilidade e Especificidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...