Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 7: 46223, 2017 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-28387382

RESUMO

We present a novel, inexpensive and non-interferometric technique to retrieve phase images by using a liquid crystal phase shifter without including any physically moving parts. First, we derive a new equation of the intensity-phase relation with respect to the change of refractive index, which is similar to the transport of the intensity equation. The equation indicates that this technique is unneeded to consider the variation of magnifications between optical images. For proof of the concept, we use a liquid crystal mixture MLC 2144 to manufacture a phase shifter and to capture the optical images in a rapid succession by electrically tuning the applied voltage of the phase shifter. Experimental results demonstrate that this technique is capable of reconstructing high-resolution phase images and to realize the thickness profile of a microlens array quantitatively.

2.
J Med Biol Eng ; 35(3): 305-314, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26167141

RESUMO

Si-based antiresonant reflecting optical waveguide type B (ARROW-B) surface plasmon resonance (SPR) biosensors allow label-free high-sensitivity detection of biomolecular interactions in real time. The ARROW-B waveguide, which has a thick guiding layer, provides efficient coupling with a single-mode fiber. The Si-based ARROW-B SPR biosensors were fabricated by using the standard semiconductor fabrication processes with a single-step lithography. A fluid flow system was designed to transport samples or analytes. The waveguide consists of propagation and SPR sensing regions. The propagation regions in the front and rear of the SPR sensing region have a symmetric cladding structure to isolate them from environmental changes. A high-index O-ring is used to seal the liquid flow channel. The intensity interrogation method was used to characterize the sensors. The sensitivity of the biosensors was 3.0 × 103 µW/RIU (refractive index unit) with a resolution of 6.2 × 10-5 RIU. An in situ regeneration process was designed to make the sensors reusable and eliminate re-alignment of the optical measurement system. The regeneration was realized using ammonia-hydrogen peroxide mixture solutions to remove molecules bound on the sensor surface, such as self-assembled 11-mercapto-1undecanoic acid and bovine serum albumin. SPR was used to monitor the regeneration processes. The experimental results show that the sensing response did not significantly change after the sensor was reused more than 10 times. In situ regenerations of the sensors were achieved.

3.
Appl Opt ; 54(8): 2098-105, 2015 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-25968389

RESUMO

In this research, Si-based power splitters based on dual antiresonant reflecting optical waveguides (ARROW) with remote coupling by a separation distance of 30 µm were designed and realized. Characterization of the power splitters with different lengths of the coupling region was performed. Measurement characteristics of fabricated devices with the propagation losses lower than 1.90 dB/cm and the imbalances lower than 0.60 dB show that our dual ARROW power splitters can be efficiently realized.