Artigo em Inglês | MEDLINE | ID: mdl-38787936

RESUMO

Analyses conducted by electrospray ionization (ESI) mass spectrometry (MS) typically entail performing a number of preparatory steps, which include quantity calibration and mass calibration. Quantity calibration can be affected by signal noise, while mass calibration can be affected by instrumental drift if analyses are performed over an extended period of time. Here, we present two methods for achieving these calibrations using modulation of electrospray plume by alternating electric fields and demodulating the resulting MS ion currents. For this purpose, we use an ESI source fitted with three ring electrodes between the electrospray emitter and the mass spectrometer's inlet. One of these electrodes is supplied with a sine electric signal. Optionally, a nanoESI emitter is also placed between the ring electrodes and the mass spectrometer's orifice to supply calibrant ions. The ion currents, recorded with this setup, present wave-like features. In the first variant, using a triple quadrupole mass analyzer, the ion currents are subjected to data treatment by fast Fourier transform (FFT), and the resulting FFT magnitudes are correlated with analyte concentrations to produce a calibration plot. In the second variant, using a quadrupole time-of-flight mass analyzer, the mass spectra recorded at the analyte ion current maxima are mass-checked using the m/z value of the internal standard (injected via nanoESI emitter), which appears predominantly in the time intervals corresponding to the analyte ion current minima. The setup has been characterized using simulation software and optimized. Overall, the method enables the preparation of quantity calibration plots and monitoring (minor) m/z drifts during prolonged analyses.

3.
Anal Chem ; 95(39): 14702-14709, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37725015

RESUMO

Electrospray ionization (ESI) is one of the main techniques used in mass spectrometry (MS) of nonvolatile compounds. ESI is a disordered process, in which a large number of polydisperse droplets are projected from a fluctuating Taylor cone and jet protruding ESI emitter. Here, we disclose a system for sectioning electrospray plumes to discrete packets with millisecond and submillisecond lifetime, which are introduced to the MS orifice, one at a time. A high-speed camera was triggered at 10,000 frames per second to capture consecutive images of the electrospray packets transmitted to the mass spectrometer. We further correlated the high-speed images of electrospray packets with MS signals of a test analyte (acetaminophen). Following computational treatment of the images, we determined the number of droplet observations (<300), average diameter of droplets (∼10-20 µm), and average volume of droplets (few tens of picoliters) in the individual electrospray packets. The result shows that most micrometer droplets (>10 µm) do not have any significant contribution to the MS signals. This finding is in agreement with the prior conjecture that most of the MS signals are mainly attributed to nanodroplets. Based on this finding, one can deduce that only a small number of the initial microdroplets effectively carry analyte molecules that undergo ionization. We discuss that, in future, one may propose a way to "recharge" the emitted initial micrometer droplets to increase the efficiency of conventional ESI setups.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...