1.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 36(3): 277-281, 2018 Jun 01.
Artigo em Chinês | MEDLINE | ID: mdl-29984928

RESUMO

OBJECTIVE: To explore the clinical effects of treatment denture on difficult edentulous cases before complete denture restoration. METHODS: Thirty-six patients who experienced unsuccessful restoration of conventional complete dentures were included in this study. Treatment dentures were fabricated to solve issues such as abnormal occlusion, tissue surface problems, and neuromuscular dysfunction of the stomatognathic system caused by systemic diseases. The final complete dentures were fabricated by duplicating the treatment dentures. Jaw relation index, stability, and retention were evaluated at different stages. Oral health-related quality of life was measured using the Chinese version of Oral Health Impact Profile for edentulous subjects (OHIP-EDENT). RESULTS: Among the 36 patients, 33 successfully completed the final restoration with positive effects. CONCLUSIONS: Treatment denture is an effective pre-restorative option that can be used to correct abnormal occlusion, improve tissue surface problems, and aid in neuromuscular rehabilitation training. Treatment dentures contribute to the successful restoration of the final complete dentures and is worthy of clinical applications.


Assuntos
Prótese Total , Boca Edêntula , Qualidade de Vida , Retenção de Dentadura , Humanos , Saúde Bucal , Satisfação do Paciente
2.
Artigo em Inglês | MEDLINE | ID: mdl-21989884

RESUMO

This paper describes the development of a high-frequency 256-element linear ultrasonic array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were fabricated with different commercial and experimental piezoelectric ceramics and evaluated to determine a suitable formulation for use in high-frequency linear arrays. It was found that the fabricated fine-scale 2-2 IB composites outperformed 1-3 IB composites with identical pillar- and kerf-widths. This result was not expected and lead to the conclusion that dicing damage was likely the cause of the discrepancy. Ultimately, a 2-2 composite fabricated using a fine-grain piezoelectric ceramic was chosen for the array. The composite was manufactured using one IB operation in the azimuth direction to produce approximately 19-µm-wide pillars separated by 6-µm-wide kerfs. The array had a 50 µm (one wavelength in water) azimuth pitch, two matching layers, and 2 mm elevation length focused to 7.3 mm using a polymethylpentene (TPX) lens. The measured pulse-echo center frequency for a representative array element was 28 MHz and -6-dB bandwidth was 61%. The measured single-element transmit -6-dB directivity was estimated to be 50°. The measured insertion loss was 19 dB after compensating for the effects of attenuation and diffraction in the water bath. A fine-wire phantom was used to assess the lateral and axial resolution of the array when paired with a prototype system utilizing a 64-channel analog beamformer. The -6-dB lateral and axial resolutions were estimated to be 125 and 68 µm, respectively. An anechoic cyst phantom was also imaged to determine the minimum detectable spherical inclusion, and thus the 3-D resolution of the array and beamformer. The minimum anechoic cyst detected was approximately 300 µm in diameter.


Assuntos
Ultrassonografia/instrumentação , Animais , Bovinos , Cistos/diagnóstico por imagem , Desenho de Equipamento , Olho/diagnóstico por imagem , Modelos Biológicos , Imagens de Fantasmas , Transdutores , Ultrassonografia/métodos
3.
Xi Bao Yu Fen Zi Mian Yi Xue Za Zhi ; 27(12): 1346-8, 2011 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-22368796

RESUMO

AIM: To explore the influence of two kinds of crown margin designs on MMP-8 and TIMP-1 levels in gingival crevicular fluid(GCF). METHODS: 16 cases of patients who needed full crowns were divided randomly into two groups: subgingival group and gingival crest group. The GCF were taken before tooth preparation, one month, three months and six months after crown placement. The levels of MMP-8 and TIMP-1 in GCF were determined by ELISA. RESULTS: The levels of MMP-8 and TIMP-1 in GCF before tooth preparation made as baseline. The level of MMP-8 at one month after crown placement in subgingival group was higher than the baseline ( P <0. 05) and contiue increasing at three months after crown placement. The level of MMP-8 at six months after crown placement in subgingival group decreased, but it was higher than the baseline(P<0.05). In gingival crest group, atfer inserting crowns, the levels of MMP-8 and TIMP-1 was no signifieantly change. In two gourps, atfer inserting crowns, the levels of MMP-8 and TIMP-1 signifieantly increased. The level of MMP-8 in subgingival group was higher than that in gingival crest group at all times and the level of TIMP-1 in subgingival group was lower than that in gingival crest group. CONCLUSION: Gingival crest crown margin design is more fvourable to the effect of MMP-8 and TIMP-1 in maintaining the health and the regular remodeling of the periodontium.


Assuntos
Coroas , Líquido do Sulco Gengival/química , Metaloproteinase 8 da Matriz/análise , Inibidor Tecidual de Metaloproteinase-1/análise , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Ann Biomed Eng ; 37(5): 890-901, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19280341

RESUMO

The zebrafish (Danio rerio) is an emerging model for cardiovascular research. The zebrafish heart regenerates after 20% ventricular amputation. However, assessment of the physiological responses during heart regeneration has been hampered by the small size of the heart and the necessity of conducting experiments in an aqueous environment. We developed a methodology to monitor a real-time surface electrocardiogram (ECG) by the use of micro-electrodes, signal amplification, and a low pass-filter at a sampling rate of 1 kHz. Wavelet transform was used to further remove ambient noises. Rather than paralyzing the fish, we performed mild sedation by placing the fish in a water bath mixed with MS-222 (tricane methanesulfonate). We recorded distinct P waves for atrial contraction, QRS complexes for ventricular depolarization, and QT intervals for ventricular repolarization prior to, and 2 and 4 days post-amputation (dpa). Sedation reduced the mean fish heart rate from 149 +/- 18 to 90 +/- 17 beats/min. The PR and QRS intervals remained unchanged in response to ventricular apical amputation (n = 6, p > 0.05). Corrected QT intervals (QTc) were shortened 4 dpa (n = 6, p < 0.05). In a parallel study, histology revealed that apical thrombi were replaced with fibrin clots and collagen fibers. Atrial arrhythmia was noted in response to prolonged sedation. Unlike the human counterpart, ventricular tachycardia or fibrillation was not observed in response to ventricular amputation 2 and 4 dpa. Taken together, we demonstrated a minimally invasive methodology to monitor zebrafish heart function, electrical activities, and regeneration in real-time.


Assuntos
Eletrocardiografia , Coração/fisiologia , Regeneração/fisiologia , Amputação Cirúrgica , Animais , Artefatos , Ventrículos do Coração/cirurgia , Modelos Animais , Miocárdio/patologia , Processamento de Sinais Assistido por Computador , Peixe-Zebra
5.
Artigo em Inglês | MEDLINE | ID: mdl-18986909

RESUMO

The development of a field-programmable gate array (FPGA)-based pulsed-wave Doppler processing approach in pure digital domain is reported in this paper. After the ultrasound signals are digitized, directional Doppler frequency shifts are obtained with a digital-down converter followed by a low-pass filter. A Doppler spectrum is then calculated using the complex fast Fourier transform core inside the FPGA. In this approach, a pulsed-wave Doppler implementation core with reconfigurable and real-time processing capability is achieved.


Assuntos
Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia Doppler/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Artigo em Inglês | MEDLINE | ID: mdl-18599429

RESUMO

A high-frequency angled needle ultrasound transducer with an aperture size of 0.4 x 0.56 mm2 was fabricated using a lead zinc niobate-lead titanate (PZN- 7%PT) single crystal as the active piezoelectric material. The single crystal was bonded to a conductive silver particle matching layer and a conductive epoxy backing material through direct contact curing. A parylene outer matching layer was formed by vapor deposition. Angled needle probe configuration was achieved by dicing at 45 degrees to the single crystal poling direction to satisfy a clinical request for blood flow measurement in the posterior portion of the eye. The electrical impedance magnitude and phase of the transducer were 42 Omega and -63 degrees , respectively. The measured center frequency and the fractional bandwidth at -6 dB were 43 MHz and 45%, respectively. The two-way insertion loss was approximately 17 dB. Wire phantom imaging using fabricated PZN-7%PT single crystal transducers was obtained and spatial resolutions were assessed.


Assuntos
Chumbo/química , Chumbo/efeitos da radiação , Agulhas , Nióbio/química , Nióbio/efeitos da radiação , Titânio/química , Titânio/efeitos da radiação , Transdutores , Ultrassonografia/métodos , Zinco/química , Zinco/efeitos da radiação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-16764457

RESUMO

The development of a high frequency (> 50 MHz) annular array ultrasonic transducer is presented. The array was constructed by bonding a 9 microm P(VDF-TrFE) film to a two-sided polyimide flexible circuit with annuli electrodes on the top layer. Each annulus was separated by a 30 microm kerf and had several electroplated microvias that connected to electrode traces on the bottom side of the flex circuit. In order to improve device sensitivity, each element was electrically matched to an impedance magnitude of 50 omega and 0 degrees phase at resonance using a serial inductor and high impedance coaxial cable. The array's performance was evaluated by measuring the electrical impedance, pulse echo response, and cross talk between elements. The average round trip insertion loss was -33.5 dB after compensating for diffractive and attenuative losses. The measured average center frequency and bandwidth for an element was 55 MHz and 47%, respectively. The measured cross talk between adjacent elements remained below -29 dB at the center frequency in water. A vertical wire phantom was imaged using a single focus transmit beamformer and dynamic focusing receive beamformer. This image showed a significant improvement in lateral resolution over a range of 9 mm after the dynamic focusing receive algorithm was applied. These results correlated well with predictions from a Field II simulation. After beamforming, the minimum lateral resolution achieved by the array (-6 dB) was 108 microm at the focus.

9.
Ultrasonics ; 44(3): 330-6, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16714042

RESUMO

A scheme of using phase-coded excitation and mismatched filter compression for high-frequency ultrasound imaging is presented in this paper. Biphase-coded pulses were constructed to excite the transducer. Received signals were compressed with mismatched filters optimized by minimizing peak-sidelobe-level (PSL). Both simulation and experiments were carried out to demonstrate the advantage of this technique. The simulation results demonstrated a possible sidelobe reduction (<-90 dB) with a slightly decrease of the signal-to-noise ratio of less than 1 dB compared with the compression using matched filters alone. The experimental results showed about 14 dB SNR improvement as well as -40 dB sidelobe level when the Barker-13 code excitation with 3-cycle sinusoidal wave carrier was used.


Assuntos
Acústica , Aumento da Imagem , Processamento de Sinais Assistido por Computador , Ultrassonografia , Simulação por Computador , Ultrassonografia/instrumentação , Ultrassonografia/métodos
10.
Artigo em Inglês | MEDLINE | ID: mdl-16529104

RESUMO

This is Part I of a series of two papers describing the development of a digital high-frequency, annular-array, ultrasonic imaging system. In this paper, the design and fabrication of a high-frequency annular array as well as its performance will be reported. A six-element, 50 MHz array, which incorporated an acoustic lens to provide an initial focal point, was designed and fabricated. A submicron size grain lead titanate piezoelectric ceramic was used to both reduce lateral coupling and keep the electrical impedance matched close to the 50 ohm receive electronics. The array elements were isolated using laser micromachining to fully separate the annuli, and electrical interconnection was achieved by directly soldering thin wires to the elements. The resulting array attained an average impulse response that exhibited a 43 MHz center frequency, 30% relative bandwidth, and an average insertion loss of 31 dB at 45 MHz. Maximum next-element crosstalk was -27 dB in water.


Assuntos
Transdutores , Ultrassonografia/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
11.
Artigo em Inglês | MEDLINE | ID: mdl-16529105

RESUMO

This is the second part of a two-paper series reporting a recent effort in the development of a high-frequency annular array ultrasound imaging system. In this paper an imaging system composed of a six-element, 43 MHz annular array transducer, a six-channel analog front-end, a field programmable gate array (FPGA)-based beamformer, and a digital signal processor (DSP) microprocessor-based scan converter will be described. A computer is used as the interface for image display. The beamformer that applies delays to the echoes for each channel is implemented with the strategy of combining the coarse and fine delays. The coarse delays that are integer multiples of the clock periods are achieved by using a first-in-first-out (FIFO) structure, and the fine delays are obtained with a fractional delay (FD) filter. Using this principle, dynamic receiving focusing is achieved. The image from a wire phantom obtained with the imaging system was compared to that from a prototype ultrasonic backscatter microscope with a 45 MHz single-element transducer. The improved lateral resolution and depth of field from the wire phantom image were observed. Images from an excised rabbit eye sample also were obtained, and fine anatomical structures were discerned.


Assuntos
Córnea/diagnóstico por imagem , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia/instrumentação , Animais , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnicas In Vitro , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
12.
Artigo em Inglês | MEDLINE | ID: mdl-16529106

RESUMO

A real-time digital beamformer for high-frequency (>20 MHz) linear ultrasonic arrays has been developed. The system can handle up to 64-element linear array transducers and excite 16 channels and receive simultaneously at 100 MHz sampling frequency with 8-bit precision. Radio frequency (RF) signals are digitized, delayed, and summed through a real-time digital beamformer, which is implemented using a field programmable gate array (FPGA). Using fractional delay filters, fine delays as small as 2 ns can be implemented. A frame rate of 30 frames per second is achieved. Wire phantom (20 microm tungsten) images were obtained and -6 dB axial and lateral widths were measured. The results showed that, using a 30 MHz, 48-element array with a pitch of 100 microm produced a -6 dB width of 68 microm in the axial and 370 microm in the lateral direction at 6.4 mm range. Images from an excised rabbit eye sample also were acquired, and fine anatomical structures, such as the cornea and lens, were resolved.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia/instrumentação , Sistemas Computacionais , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos