Artigo em Inglês | MEDLINE | ID: mdl-38736647

RESUMO

We report the development of a high-sensitivity and high-resolution PET subsystem for a next-generation preclinical PET/EPR hybrid scanner for investigating and improving hypoxia imaging with PET. The PET subsystem consists of 14 detector modules (DM) installed within a cylindrical supporting frame whose outer and inner diameters are 115mm and 60mm, respectively. Each DM contains eight detector units (DU) in a row and each DU is made of a 12×12 array of 1×1×10mm3 LYSO crystals (with a 1.05mm pitch) coupled to a 4×4 silicon photomultiplier (SiPM) array that has a 3.2mm pitch (Hamamatsu multi-pixel photon counter (MPPC) array 14161-3050HS-04). The PET subsystem has a 104mm axial field-of-view (AFOV) that is sufficient for full-body mouse imaging, therefore enabling temporal and spatial correlation studies of tumor hypoxia between PET and EPR. It employs 1mm-width crystals to support sub-millimeter image resolution that is desired for mouse imaging. Al-though a DM contains 1,152 LYSO crystals, by use of a newly devised signal readout method only six outputs are produced. Recently a partial prototype of this subsystem consisting of four DMs is built. In this paper, we present performance measurement results obtained for the developed DMs and initial imaging results obtained by the prototype. The developed DMs show uniformly superior performance in identifying the hit crystal and detector unit, in energy resolution, and in coincidence time resolution. The images obtained for a 22Na point source and a 18F-filled U-shaped tube source show an image resolution of about 1.1mm and 1.2mm FWHM in the transverse and axial directions respectively, and demonstrate successful imaging over the entire 104mm AFOV of the prototype. This estimated image resolution however includes the contribution by the source size.

2.
IEEE Trans Radiat Plasma Med Sci ; 8(3): 269-276, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38654812

RESUMO

We investigate a highly multiplexing readout for depth-of-interaction (DOI) and time-of-flight PET detector consisting of an N×N crystals whose light outputs at the front and back ends are detected by using silicon photomultipliers (SiPM). The front N×N SiPM array is read by using a stripline (SL) configured to support discrimination of the row position of the signal-producing crystal. The back N×N SiPM array is similarly read by an SL for column discrimination. Hence, the detector has only four outputs. We built 4×4 and 8×8 detector modules (DM) by using 3.0×3.0×20 mm3 lutetium-yttrium oxyorthosilicates. The outputs were sampled and processed offline. For both DMs, crystal discrimination was successful. For the 4×4 DM, we obtained an average energy resolution (ER) of 14.1%, an average DOI resolution of 2.5 mm, a non DOI-corrected coincidence resolving time (CRT), measured in coincidence with a single-pixel reference detector, of about 495 ps. For the 8×8 DM, the average ER, average DOI resolution and average CRT were 16.4%, 2.9 mm, and 641 ps, respectively. We identified the intercrystal scattering as a probable cause for the CRT deterioration when the DM was increased from 4×4 to 8×8.

3.
IEEE Trans Radiat Plasma Med Sci ; 7(8): 794-801, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37981977

RESUMO

We report the design and experimental validation of a compact positron emission tomography (PET) detector module (DM) intended for building a preclinical PET and electron-paramagnetic-resonance-imaging hybrid system that supports sub-millimeter image resolution and high-sensitivity, whole-body animal imaging. The DM is eight detector units (DU) in a row. Each DU contains 12×12 lutetium-yttrium oxyorthosilicate (LYSO) crystals having a 1.05 mm pitch read by 4×4 silicon photomultipliers (SiPM) having a 3.2 mm pitch. A small-footprint, highly-multiplexing readout employing only passive electronics is devised to produce six outputs for the DM, including two outputs derived from SiPM cathodes for determining event time and active DU and four outputs derived from SiPM anodes for determining energy and active crystal. Presently, we have developed two DMs that are 1.28×10.24 cm2 in extent and approximately 1.8 cm in thickness, with their outputs sampled at 0.7 GS/s and analyzed offline. For both DMs, our results show successfully discriminated DUs and crystals. With no correction for SiPM nonlinearity, the average energy resolution for crystals in a DU ranges from 14% to 16%. While not needed for preclinical imaging, the DM may support 300-400 ps time-of-flight resolution.

4.
Phys Med Biol ; 68(7)2023 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-36821861

RESUMO

Objective.X-ray scatter leads to signal bias and degrades the image quality in Computed Tomography imaging. Conventional real-time scatter estimation and correction methods include the scatter kernel superposition (SKS) methods, which approximate x-ray scatter field as a convolution of the scatter sources and scatter propagation kernels to reflect the spatial spreading of scatter x-ray photons. SKS methods are fast to implement but generally suffer from low accuracy due to the difficulties in determining the scatter kernels.Approach.To address such a problem, this work describes a new scatter estimation and correction method by combining the concept of SKS methods and convolutional neural network. Unlike conventional SKS methods which estimate the scatter amplitude and the scatter kernel based on the value of an individual pixel, the proposed method generates the scatter amplitude maps and the scatter width maps from projection images through a neural network, from which the final estimated scatter field is calculated based on a convolution process.Main Results.By incorporating physics in the network design, the proposed method requires fewer trainable parameters compared with another deep learning-based method (Deep Scatter Estimation). Both numerical simulations and physical experiments demonstrate that the proposed SKS-inspired convolutional neural network outperforms the conventional SKS method and other deep learning-based methods in both qualitative and quantitative aspects.Significance.The proposed method can effectively correct the scatter-related artifacts with a SKS-inspired convolutional neural network design.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Espalhamento de Radiação , Método de Monte Carlo , Redes Neurais de Computação , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos
5.
IEEE Trans Radiat Plasma Med Sci ; 5(5): 662-670, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34541433

RESUMO

A recent trend in PET instrumentation is the use of silicon photomultipliers (SiPMs) for high-resolution and time-of-flight (TOF) detection. Due to its small size, a PET system can use a large number of SiPMs and hence effective and scalable multiplexing readout methods become important. Unfortunately, multiplexing readout generally degrades the fast timing properties necessary for TOF, especially at high channel reduction. Previously, we developed a stripline (SL) based readout method for PET that uses a time-based multiplexing mechanism. This method maintains fast timing by design and has been successfully used for TOF PET detectors. In this paper, we present a more systematic study in which we examine how two important design parameters of the readout - the number of inputs on an SL (n SL) and the pathlength between adjacent input positions (Δℓ) - affect its detection performance properties for PET. Our result shows that, up to n SL = 32 the readout can achieve accurate pixel discrimination and causes little degradation in the energy resolution. The TOF resolution is compromised mildly and a coincidence resolving time on the order of 300 ps FWHM can be achieved for LYSO- and SiPM-based detectors. We also discuss strategies in using the readout to further reduce the number of electronic channels that a PET system would otherwise need.

6.
EJNMMI Res ; 10(1): 155, 2020 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-33301074

RESUMO

BACKGROUND: We investigated the image quality of 11C, 68Ga, 18F and 89Zr, which have different positron fractions, physical half-lifes and positron ranges. Three small animal positron emission tomography/computed tomography (PET/CT) systems were used in the evaluation, including the Siemens Inveon, RAYCAN X5 and Molecubes ß-cube. The evaluation was performed on a single scanner level using the national electrical manufacturers association (NEMA) image quality phantom and analysis protocol. Acquisitions were performed with the standard NEMA protocol for 18F and using a radionuclide-specific acquisition time for 11C, 68Ga and 89Zr. Images were assessed using percent recovery coefficient (%RC), percentage standard deviation (%STD), image uniformity (%SD), spill-over ratio (SOR) and evaluation of image quantification. RESULTS: 68Ga had the lowest %RC (< 62%) across all systems. 18F had the highest maximum %RC (> 85%) and lowest %STD for the 5 mm rod across all systems. For 11C and 89Zr, the maximum %RC was close (> 76%) to the %RC with 18F. A larger SOR were measured in water with 11C and 68Ga compared to 18F on all systems. SOR in air reflected image reconstruction and data correction performance. Large variation in image quantification was observed, with maximal errors of 22.73% (89Zr, Inveon), 17.54% (89Zr, RAYCAN) and - 14.87% (68Ga, Molecubes). CONCLUSIONS: The systems performed most optimal in terms of NEMA image quality parameters when using 18F, where 11C and 89Zr performed slightly worse than 18F. The performance was least optimal when using 68Ga, due to large positron range. The large quantification differences prompt optimization not only by terms of image quality but also quantification. Further investigation should be performed to find an appropriate calibration and harmonization protocol and the evaluation should be conducted on a multi-scanner and multi-center level.

7.
J Med Imaging (Bellingham) ; 4(1): 011006, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28018941

RESUMO

We report the development of a modularized compact positron emission tomography (PET) detector that outputs serial streams of digital samples of PET event pulses via an Ethernet interface using the UDP/IP protocol to enable rapid configuration of a PET system by connecting multiple such detectors via a network switch to a computer. Presently, the detector is [Formula: see text] in extent (excluding I/O connectors) and contains an [Formula: see text] array of [Formula: see text] one-to-one coupled lutetium-yttrium oxyorthosilicate/silicon photomultiplier pixels. It employs cross-wire and stripline readouts to merge the outputs of the 216 detector pixels to 24 channels. Signals at these channels are sampled using a built-in 24-ch, 4-level field programmable gate arrays-only multivoltage threshold digitizer. In the computer, software programs are implemented to analyze the digital samples to extract event information and to perform energy qualification and coincidence filtering. We have developed two such detectors. We show that all their pixels can be accurately discriminated and measure a crystal-level energy resolution of 14.4% to 19.4% and a detector-level coincidence time resolution of 1.67 ns FWHM. Preliminary imaging results suggests that a PET system based on the detectors can achieve an image resolution of [Formula: see text].