1.
Adv Manuf ; 9(1): 130-135, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33425459

RESUMO

The World Health Organization emphasized the importance of goggles and face shields for protection of medical personnel at the outbreak of the COVID-19 pandemic. Unsurprisingly, almost all countries suffered from a critical supply shortage of goggles and face shields, as well as many other types of personal protective equipment (PPE), for a long period, owing to the lack of key medical material supplies and the inefficiency of existing fabrication methods arising from the need to avoid crowds during the outbreak of COVID-19. In this paper, we propose a novel combined shield design for eye and face protection that can be rapidly fabricated using three-dimensional printing technology. The designed prototype eye-face shield is accessible to the general public, offering more possibilities for yield improvement in PPE during emergent infectious disease events such as COVID-19.

2.
J Mech Behav Biomed Mater ; 82: 87-94, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29574279

RESUMO

Ultra-low-wear polyethylene (ULWPE) is a new type polyethylene made by experts who are from China petrochemical research institute, which is easy to process and implant. Preliminary test showed it was more resistant to wear than that of Ultra-high-molecular weight polyethylene (UHMWPE). The purpose of the research is to study biocompatibility, bio-tribological properties and debris characterization of ULWPE. Cytotoxicity test, hemolysis test, acute/chronic toxicity and muscular implantation test were conducted according to national standard GB/T-16886/ISO-10993 for evaluation requirements of medical surgical implants. We obtained that this novel material had good biocompatibility and biological safety. The wear performance of ULWPE and UHMWPE was evaluated in a pin-on-disc (POD) wear tester within two million cycles and a knee wear simulator within six million cycles. We found that the ULWPE was higher abrasion resistance than the UHMWPE, the wear rate of ULWPE by POD test and knee wear simulator was 0.4 mg/106cycles and (16.9 ±â€¯1.8)mg/106cycles respectively, while that of UHMWPE was 1.8 mg/106cycles and (24.6 ±â€¯2.4)mg/106cycles. The morphology of wear debris is also an important factor to evaluate artificial joint materials, this study showed that the ULWPE wear debris gotten from the simulator had various different shapes, including spherical, block, tear, etc. The morphology of worn surface and wear debris analysis showed that wear mechanisms of ULWPE were adhesion wear, abrasive wear and fatigue wear and other wear forms, which were consistent with that of UHMWPE. Thus we conclude that ULWPE is expected to be a lifetime implantation of artificial joint.


Assuntos
Prótese Articular , Teste de Materiais , Polietilenos/toxicidade , Linhagem Celular , Hemólise/efeitos dos fármacos , Fenômenos Mecânicos , Polietilenos/química , Propriedades de Superfície
3.
Int Orthop ; 41(6): 1183-1187, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28353052

RESUMO

PURPOSE: Posterior reduction and pedicle screw fixation is a widely used procedure for thoracic and lumbar vertebrae fractures. Usually, the pedicle screws would be removed after the fracture healing and screw tunnels would be left. The aim of this study is to evaluate the effect of screw tunnels on the biomechanical stability of the lumbar vertebral body after pedicle screws removal by finite element analysis (FEA). METHODS: First, the CT values of the screw tunnels wall in the fractured vertebral bodies were measured in patients whose pedicle screws were removed, and they were then compared with the values of vertebral cortical bone. Second, an adult patient was included and the CT images of the lumbar spine were harvested. Three dimensional finite element models of the L1 vertebra with unilateral or bilateral screw tunnels were created based on the CT images. Different compressive loads were vertically acted on the models. The maximum loads which the models sustained and the distribution of the force in the different parts of the models were recorded and compared with each other. RESULTS: The CT values of the tunnels wall and vertebral cortical bone were 387.126±62.342 and 399.204±53.612, which were not statistically different (P=0.149). The models of three dimensional tetrahedral mesh finite element of normal lumbar 1 vertebra were established with good geometric similarity and realistic appearance. After given the compressive loads, the cortical bone was the first one to reach its ultimate stress. The maximum loads which the bilateral screw tunnels model, unilateral screw tunnel model, and normal vertebral model can sustain were 3.97 Mpa, 3.83 Mpa, and 3.78 Mpa, respectively. For the diameter of the screw tunnels, the model with a diameter of 6.5 mm could sustain the largest load. In addition, the stress distributing on the outside of the cortical bone gradually decreased as the thickness of the tunnel wall increased. CONCLUSIONS: Based on the FEA, pedicle screw tunnels would not decrease the biomechanical stability and strength of the vertebral body. A large diameter of screw tunnel and thick tunnel wall were helpful for the biomechanical stability of the vertebral body.


Assuntos
Parafusos Ósseos/efeitos adversos , Vértebras Lombares/cirurgia , Parafusos Pediculares/efeitos adversos , Fraturas da Coluna Vertebral/cirurgia , Adulto , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Tomografia Computadorizada por Raios X , Adulto Jovem