Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6208-6211, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947261

RESUMO

An instrumented ultrasound probe system is designed to estimate the distribution of pressure applied across the probe face during image acquisition. The pressure distribution is used to investigate the effects of varying, and non-uniform, pressure distributions on shear wave elastography measurements in phantoms and ex vivo samples. Pressure distribution has a notable effect on shear wave elastography of ex vivo samples. The gradient in applied pressure across the probe face is mirrored in the gradient of elasticity measurements across the ultrasound elastogram image.


Assuntos
Técnicas de Imagem por Elasticidade , Ultrassonografia/instrumentação , Animais , Bovinos , Elasticidade , Fígado/diagnóstico por imagem , Fenômenos Mecânicos , Imagens de Fantasmas
2.
IEEE Trans Biomed Eng ; 65(11): 2405-2416, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30281436

RESUMO

OBJECTIVE: Our objective is to create a blood pressure measurement device, which may provide a way to easily acquire frequent measurements. Common techniques to measure blood pressure include an arterial catheter, an oscillometric pressure cuff, or an auscultatory pressure cuff. METHODS: The approach takes as input ultrasound images of an artery and contact force between the ultrasound array and subject. A subject may perform the self-measurements. Image and force data is analyzed for its quality and used to provide guidance or reject poor measurements. Tissue motions, due to probe contact forces and pulsing blood pressure, are estimated from the ultrasound image. Tissues elasticities and blood pressure are found by optimally fitting the observed tissue motion versus applied forces to a table of predicted motion-pre-generated with a finite element tissue deformation model. The output of the optimization is an estimate of systolic and diastolic blood pressure, arterial stiffness, and surrounding tissue stiffness. RESULTS: The real-time implementation of the algorithm was validated on a cohort of 21 single-visit volunteers and on four volunteers self-monitored longitudinally. The systolic and diastolic pressures were compared to oscillometric cuff readings. Regression and Bland-Altman analyses were performed. CONCLUSION: Systolic pressure and diastolic pressure can be estimated in real-time and by the subject using this novel non-invasive ultrasound-based method (systolic accuracy/precision: -5.2 mmHg/10.7 mmHg; diastolic accuracy/precision: -3.9/8.0 mmHg). SIGNIFICANCE: The method occupies a middle ground between the arterial catheter and cuff-based techniques. It has the potential to give calibration-free results.


Assuntos
Determinação da Pressão Arterial/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Pressão Sanguínea/fisiologia , Artérias Carótidas , Humanos , Ultrassonografia