Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Chem A ; 127(45): 9550-9563, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37930654

RESUMO

The IR spectra of benzoic acid (BA), (BA)(H2O)n and (BA)2(H2O)n (n = 1, 2) clusters, and their ring-deuterated isotopologues in the 2800-3750 cm-1 region were measured with IR-vacuum ultraviolet spectroscopy under the jet-cooled condition. For (BA)(H2O) and (BA)(H2O)2, only a single isomer was observed for each species, whereas for (BA)2(H2O) and (BA)2(H2O)2, more than one isomers were present. The observed IR spectra were very complex and showed similar structures between (BA)m(H2O)n and their ring-deuterated isotopologues (BA-d5)m(H2O)n for specific values of m and n. The anharmonic analysis based on the vibrational second-order perturbation theory indicated that the complexity of the IR spectra in these clusters was due to the appearance of many bands of (i) the overtone and combination modes involving the O-H bend of H2O and the in-plane C-O-H bends and the C═O stretch of BA, and (ii) the combination modes involving the hydrogen-bonded O-H stretch and low-frequency intermolecular vibrations, with considerable intensities.

2.
J Chin Med Assoc ; 84(8): 795-798, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34145200

RESUMO

BACKGROUND: Static progressive orthosis is used for the treatment of severe joint contracture after trauma and/or surgery. However, a custom-fabricated static progressive splint would be expensive and labor intensive. Especially, owing to very limited payment under the current Taiwanese National Health Insurance, the incentives to fabricate a patient-specific splint are insufficient for a therapist. To ease splint construction, we introduced three-dimensional (3D)-printed "shark fin"-shaped device works as a static progressive orthosis for the hand rehabilitation. The aim of this study was to describe and demonstrate the newly designed device. METHODS: This study included a 46-year male suffered from a left distal radius fracture and underwent open reduction internal fixation and a 23-year male with the right thumb flexor pollicis longus rupture, requiring tendon repair. Both subjects used this "shark fin"-shaped device to stretch for increasing range of motion (ROM) of wrist extension and the thumb. RESULTS: The patient receiving ulnar shortening surgery used this device to stretch for increasing ROM of wrist extension. The active ROM of wrist extension improved from 30° to 50°. The other patient with the right thumb flexor pollicis longus rupture suffered from thumb contracture; the ROMs of the metacarpophalangeal (MCP) joint and interphalangeal (IP) joint were 40°-55° and 20°-25°, respectively. After tenolysis surgery, his ROMs of the MCP and IP joints were improved to 10°-35° and 40°-65°, respectively. Following physical therapy by applying the device, his ROMs of the MCP and IP joints were further increased to 0°-40° and 25°-70°, respectively. CONCLUSION: Incorporating the "shark fin"-shaped orthosis into hand rehabilitation increased the ROM of wrist extension for a patient with distal radius fracture and improved the ROM of the MCP and IP joints in another patient after tenolysis surgery.


Assuntos
Traumatismos da Mão/reabilitação , Aparelhos Ortopédicos , Impressão Tridimensional , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...