Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Nanobioscience ; 14(8): 967-72, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26595926

RESUMO

Here we report successful demonstration of a FET-like electrochemical nano-biosensor to accurately detect ultralow concentrations of adenosine triphosphate. As a 2D material, graphene is a promising candidate due to its large surface area, biocompatibility, and demonstrated surface binding chemistries and has been employed as the conducting channel. A short 20-base DNA aptamer is used as the sensing element to ensure that the interaction between the analyte and the aptamer occurs within the Debye length of the electrolyte (PBS). Significant increase in the drain current with progressive addition of ATP is observed whereas for control experiments, no distinct change in the drain current occurs. The sensor is found to be highly sensitive in the nanomolar (nM) to micromolar ( µM) range with a high sensitivity of 2.55 µA (mM) (-1), a detection limit as low as 10 pM, and it has potential application in medical and biological settings to detect low traces of ATP. This simplistic design strategy can be further extended to efficiently detect a broad range of other target analytes.


Assuntos
Trifosfato de Adenosina/análise , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Grafite/química , Nanotecnologia/instrumentação , Transistores Eletrônicos , Trifosfato de Adenosina/química , Desenho de Equipamento
2.
Biosens Bioelectron ; 71: 294-299, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-25919809

RESUMO

One of the primary goals in the scientific community is the specific detection of proteins for the medical diagnostics and biomedical applications. Interferon-gamma (IFN-γ) is associated with the tuberculosis susceptibility, which is one of the major health problems globally. We have therefore developed a DNA aptamer-based electrochemical biosensor that is used for the detection of IFN-γ with high selectivity and sensitivity. A graphene monolayer-based FET-like structure is incorporated on a PDMS substrate with the IFN-γ aptamer attached to graphene. Addition of target molecule induces a change in the charge distribution in the electrolyte, resulting in increase in electron transfer efficiency that was actively sensed by monitoring the change in current from the device. Change in current appears to be highly sensitive to the IFN-γ concentrations ranging from nanomolar (nM) to micromolar (µM) range. The detection limit of our IFN-γ electrochemical biosensor is found to be 83 pM. Immobilization of aptamer on graphene surface is verified using unique structural approach by Atomic Force Microscopy. Such simple and sensitive electrochemical biosensor has potential applications in infectious disease monitoring, immunology and cancer research in the future.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Interferon gama/análise , Transistores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Interferon gama/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...