Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(3)2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36768623

RESUMO

The detection of circulating tumor cells (CTCs) is an emerging strategy for the early detection, prognostication, and identification of recurrent cancer. The clinical utility of CTC detection has been established, but few studies have employed this strategy for the detection of gynecologic cancers. Here, we present a novel, biochip-based microfluidic device for the detection of CTCs in gynecologic cancers. The study cohort included three patients with cervical cancer, eight with endometrial cancer, two with ovarian cancer, two with breast cancer, and one with vaginal small cell carcinoma. Four cancer type-specific molecular markers (PanCK, GATA3, HER2, and HE4), as well as CD13, were used for prognostication and recurrence detection, along with downstream genomic analysis. GATA3 and HER2 were markedly expressed in the patients with cervical cancer, and this expression was strongly correlated with the early detection of recurrent disease. All four molecular markers were expressed preoperatively in the patients with endometrial cancer, and the re-expression of different markers was observed at follow-up before recurrence was confirmed. CD13 was identified as an alternative prognostic marker for both cervical and endometrial cancer. Our pilot study indicated that the novel CTC detection system can be used for prognostication and early detection of disease recurrence, which needed further investigation.


Assuntos
Neoplasias da Mama , Neoplasias do Endométrio , Neoplasias dos Genitais Femininos , Células Neoplásicas Circulantes , Neoplasias do Colo do Útero , Humanos , Feminino , Células Neoplásicas Circulantes/patologia , Microfluídica , Projetos Piloto , Recidiva Local de Neoplasia/diagnóstico , Neoplasias dos Genitais Femininos/diagnóstico , Neoplasias da Mama/metabolismo , Neoplasias do Endométrio/diagnóstico , Neoplasias do Endométrio/patologia , Biomarcadores Tumorais
2.
Int J Mol Sci ; 23(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36499466

RESUMO

Single-cell sequencing provides promising information in tumor evolution and heterogeneity. Even with the recent advances in circulating tumor cell (CTC) technologies, it remains a big challenge to precisely and effectively isolate CTCs for downstream analysis. The Cell RevealTM system integrates an automatic CTC enrichment and staining machine, an AI-assisted automatic CTC scanning and identification system, and an automatic cell picking machine for CTC isolation. H1975 cell line was used for the spiking test. The identification of CTCs and the isolation of target CTCs for genetic sequencing were performed from the peripheral blood of three cancer patients, including two with lung cancer and one with both lung cancer and thyroid cancer. The spiking test revealed a mean recovery rate of 81.81% even with extremely low spiking cell counts with a linear relationship between the spiked cell counts and the recovered cell counts (Y = 0.7241 × X + 19.76, R2 = 0.9984). The three cancer patients had significantly higher TTF-1+ CTCs than healthy volunteers. All target CTCs were successfully isolated by the Cell Picker machine for a subsequent genetic analysis. Six tumor-associated mutations in four genes were detected. The present study reveals the Cell RevealTM platform can precisely identify and isolate target CTCs and then successfully perform single-cell sequencing by using commercially available genetic devices.


Assuntos
Neoplasias Pulmonares , Células Neoplásicas Circulantes , Humanos , Células Neoplásicas Circulantes/patologia , Separação Celular , Linhagem Celular Tumoral , Dispositivos Lab-On-A-Chip , Neoplasias Pulmonares/genética
3.
Diagnostics (Basel) ; 11(6)2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34208639

RESUMO

Epithelial ovarian cancer (EOC) is a leading cause of cancer mortality among women but unfortunately is usually not diagnosed until advanced stage. Early detection of EOC is of paramount importance to improve outcomes. Liquid biopsy of circulating tumor cells (CTCs) is emerging as one of the promising biomarkers for early detection of solid tumors. However, discrepancies in terms of oncogenomics (i.e., different genetic defects detected) between the germline, primary tumor, and liquid biopsy are a serious concern and may adversely affect downstream cancer management. Here, we illustrate the potential and pitfalls of CTCs by presenting two patients of Stage I EOC. We successfully isolated and recovered CTCs by a silicon-based nanostructured microfluidics system, the automated Cell RevealTM. We examined the genomics of CTCs as well as the primary tumor and germline control (peripheral blood mononuclear cells) by whole exome sequencing. Different signatures were then investigated by comparisons of identified mutation loci distinguishing those that may only arise in the primary tumor or CTCs. A novel model is proposed to test if the highly variable allele frequencies, between primary tumor and CTCs results, are due to allele dropout in plural CTCs or tumor heterogeneity. This proof-of-principle study provides a strategy to elucidate the possible cause of genomic discrepancy between the germline, primary tumor, and CTCs, which is helpful for further large-scale use of such technology to be integrated into clinical management protocols.

4.
Micromachines (Basel) ; 10(2)2019 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-30781548

RESUMO

Circulating fetal cells (CFCs) in maternal blood are rare but have a strong potential to be the target for noninvasive prenatal diagnosis (NIPD). "Cell RevealTM system" is a silicon-based microfluidic platform capable to capture rare cell populations in human circulation. The platform is recently optimized to enhance the capture efficiency and system automation. In this study, spiking tests of SK-BR-3 breast cancer cells were used for the evaluation of capture efficiency. Then, peripheral bloods from 14 pregnant women whose fetuses have evidenced non-maternal genomic markers (e.g., de novo pathogenic copy number changes) were tested for the capture of circulating fetal nucleated red blood cells (fnRBCs). Captured cells were subjected to fluorescent in situ hybridization (FISH) on chip or recovered by an automated cell picker for molecular genetic analyses. The capture rate for the spiking tests is estimated as 88.1%. For the prenatal study, 2⁻71 fnRBCs were successfully captured from 2 mL of maternal blood in all pregnant women. The captured fnRBCs were verified to be from fetal origin. Our results demonstrated that the Cell RevealTM system has a high capture efficiency and can be used for fnRBC capture that is feasible for the genetic diagnosis of fetuses without invasive procedures.

5.
Mol Cytogenet ; 10: 44, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29213331

RESUMO

BACKGROUND: Noninvasive prenatal testing (NIPT) based on cell-free DNA in maternal circulation has been accepted worldwide by the clinical community since 2011 but limitations, such as maternal malignancy and fetoplacental mosaicism, preclude its full replacement of invasive prenatal diagnosis. We present a novel silicon-based nanostructured microfluidics platform named as "Cell Reveal™" to demonstrate the feasibility of capturing circulating fetal nucleated red blood cells (fnRBC) and extravillous cytotrophoblasts (EVT) for cell-based noninvasive prenatal diagnosis (cbNIPD). METHODS: The "Cell Reveal™" system is a silicon-based, nanostructured microfluidics using immunoaffinity to capture the trophoblasts and the nucleated RBC (nRBC) with specific antibodies. The automated computer analysis software was used to identify the targeted cells through additional immunostaining of the corresponding antigens. The identified cells were retrieved for whole genome amplification for subsequent investigations by micromanipulation in one microchip, and left in situ for subsequent fluorescence in situ hybridization (FISH) in another microchip. When validation, bloods from pregnant women (n = 24) at gestational age 11-13+6 weeks were enrolled. When verification, bloods from pregnant women (n = 5) receiving chorionic villus sampling or amniocentesis at gestation age 11+4-21 weeks with an aneuploid or euploid fetus were enrolled, followed by genetic analyses using FISH, short tandem repeat (STR) analyses, array comparative genomic hybridization, and next generation sequencing, in which the laboratory is blind to the fetal genetic complement. RESULTS: The numbers of captured targeted cells were 1-44 nRBC/2 ml and 1-32 EVT/2 ml in the validation group. The genetic investigations performed in the verification group confirmed the captured cells to be fetal origin. In every 8 ml of the maternal blood being blindly tested, both fnRBC and EVT were always captured. The numbers of captured fetal cells were 14-22 fnRBC/4 ml and 1-44 EVT/4 ml of maternal blood. CONCLUSIONS: This report is one of the first few to verify the capture of fnRBC in addition to EVT. The scalability of our automated system made us one step closer toward the goal of in vitro diagnostics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...