Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 43(6): 888-92, 2012 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-23387220

RESUMO

OBJECTIVE: To identify the determinants of serum cystatin-C (Cys C) in patients. METHODS: The medical records of 31235 patients admitted to West China hospital from September to October, 2009 and their first laboratorial test results were examined. Liner regression analyses were performed to determine the association of sex, age, renal function, and metabolic index serum Cys C. One-way ANOVA and LSD tests were performed to determine the association between different diseases and serum Cys C. RESULTS: The multiple linear regression equation was obtained: Cys C = 0.331 + 0. 686Crea + 0. 174Urea + 0.119Age + 0. 068Uric - 0. 057HDL-C -0.041Sex + 0.038eGFR -0.031LDL-C -0. 026Glu, with a correlation coefficient of 0. 859 and a coefficient of determination of 0. 738. The level of serum Cys C varied with different diseases, with urinary diseases showing the highest level followed by vascular and respiratory diseases. CONCLUSION: Serum Cys C is associated with renal function, but not with metabolic index. Cys C tends to rise in patients renal function injury.


Assuntos
Cistatina C/sangue , Nefropatias/sangue , Nefropatias/fisiopatologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Testes de Função Renal , Metabolismo dos Lipídeos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Adulto Jovem
2.
Zhonghua Yi Xue Za Zhi ; 90(22): 1522-5, 2010 Jun 08.
Artigo em Chinês | MEDLINE | ID: mdl-20973231

RESUMO

OBJECTIVE: To evaluate the review criteria for complete blood analysis. METHODS: total of 8820 blood samples taken at our hospital were detected both by the Sysmex XE-2100 automated blood cell analyzer and double-blind method microscopy. The performance of two review criteria were evaluated by statistical analysis. The parameters, such as true and false positive rates, true and false negative rates, sensitivity, specificity, positive predictive value, negative predictive value, total effective rate, test effectiveness and re-examination rate were calculated according to the criteria of XE-2100 hematology analyzer re-examination standards coordination group of Society of Laboratory Medicine of Chinese Medical Association. And a study was conducted to determine the improved clinical effectiveness over the criteria. RESULTS: The values of true and false positive rates, true and false negative rates, sensitivity, specificity, positive predictive values, negative predictive value, total effective rate, test effectiveness and reexamination rate were 13.0%, 27.2%, 55.3%, 4.5%, 74.3%, 67.0%, 32.4%, 92.5%, 68.3%, 21.2%, and 40.2% respectively. The re-examination rate decreased to 33.8% and the total effective rate increased to 74.7% according to our improved review criteria. And there was no missed diagnosis of leukemic cells. It was found that 2069 samples (23.5%) needed manual microscopy for WBC differential analysis, 847 had abnormal cells and no leukemia was missed. CONCLUSIONS: The automatic blood cell analyzer and WBC differential analysis review criteria have great clinical utilities. The review criteria of blood cell analysis may be improved according to patient source and instrument performance so as to better meet the needs of clinical application.


Assuntos
Contagem de Células Sanguíneas/métodos , Automação Laboratorial/métodos , Estudos de Avaliação como Assunto , Reações Falso-Negativas , Reações Falso-Positivas , Hematologia/métodos , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...