Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
Anal Chem ; 96(24): 10013-10020, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38836548

RESUMO

Traditional methods for the detection of pathogenic bacteria are time-consuming, less efficient, and sensitive, which affects infection control and bungles illness. Therefore, developing a method to remedy these problems is very important in the clinic to diagnose the pathogenic diseases and guide the rational use of antibiotics. Here, microfluidic electrochemical integrated sensor (MEIS) has been investigated, functionally for rapid, efficient separation and sensitive detection of pathogenic bacteria. Three-dimensional macroporous PDMS and Au nanotube-based electrode are successfully assembled into the modeling microchip, playing the functions of "3D chaotic flow separator" and "electrochemical detector," respectively. The 3D chaotic flow separator enhances the turbulence of the fluid, achieving an excellent bacteria capture efficiency. Meanwhile, the electrochemical detector provides a quantitative signal through enzyme-linked immunoelectrochemistry with improved sensitivity. The microfluidic electrochemical integrated sensor could successfully isolate Candida albicans (C. albicans) in the range of 30-3,000,000 CFU in the saliva matrix with over 95% capture efficiency and sensitively detect C. albicans in 1 h in oral saliva samples. The integrated device demonstrates great potential in the diagnosis of oral candidiasis and is also applicable in the detection of other pathogenic bacteria.


Assuntos
Candida albicans , Técnicas Eletroquímicas , Candida albicans/isolamento & purificação , Técnicas Eletroquímicas/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Saliva/microbiologia , Saliva/química , Eletrodos , Humanos , Ouro/química
2.
Chem Sci ; 15(20): 7651-7658, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38784745

RESUMO

Synaptic plasticity is the ability of synapses to modulate synaptic strength in response to dynamic changes within, as well as environmental changes. Although there is a considerable body of knowledge on protein expression and receptor migration in different categories of synaptic plasticity, the contribution and impact of presynaptic vesicle release and neurotransmitter levels towards plasticity remain largely unclear. Herein, nanoelectrochemistry using carbon fiber nanoelectrodes with excellent spatio-temporal resolution was applied for real-time monitoring of presynaptic vesicle release of dopamine inside single synapses of dopaminergic neurons, and exocytotic variations in quantity and kinetics under repetitive electrical stimuli. We found that the presynaptic terminal tends to maintain synaptic strength by rapidly recruiting vesicles, changing the dynamics of exocytosis, and maintaining sufficient neurotransmitter release in following stimuli. Except for small clear synaptic vesicles, dense core vesicles are involved in exocytosis to sustain the neurotransmitter level in later periods of repetitive stimuli. These data indicate that vesicles use a potential regulatory mechanism to establish short-term plasticity, and provide new directions for exploring the synaptic mechanisms in connection and plasticity.

3.
Chem Commun (Camb) ; 60(42): 5546-5549, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38700121

RESUMO

Airborne nanoplastics can enter alveolar cells and trigger intracellular oxidative stress primarily. Herein, taking advantage of the high electrochemical resolution of SiC@Pt nanoelectrodes, we achieved the quantitative discrimination of the major ROS/RNS within A549 cells, disclosed the sources of their precursors, and observed that the NO (RNS precursor) level significantly increased, whereas O2˙- (ROS precursor) remained relatively stable during the nanoplastics exposure. This establishes that iNOS or mitochondrion-targeted treatment may be a preventive or therapeutic strategy for nanoplastic-induced lung injury.


Assuntos
Técnicas Eletroquímicas , Espécies Reativas de Nitrogênio , Espécies Reativas de Oxigênio , Humanos , Espécies Reativas de Oxigênio/metabolismo , Células A549 , Espécies Reativas de Nitrogênio/metabolismo , Estresse Oxidativo/efeitos dos fármacos , Eletrodos
4.
Analyst ; 149(13): 3530-3536, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38757525

RESUMO

ATP plays a crucial role in cell energy supply, so the quantification of intracellular ATP levels is particularly important for understanding many physio-pathological processes. The intracellular quantification of this non-electroactive molecule can be realized using aptamer-modified nanoelectrodes, but is hindered by the limited quantity of modification and electroactive tags on the nanosized electrodes. Herein, we developed a simple but effective electrochemical signal amplification strategy for intracellular ATP detection, which replaces the regular ATP aptamer-linked ferrocene monomer with a polymer, thus greatly magnifying the amounts of electrochemical reporters linked to one chain of the aptamer and enhancing the signals. This ferrocene polymer-ATP aptamer was further immobilized onto Au nanowire electrodes (SiC@C@Au NWEs) to achieve accurate quantification of intracellular ATP in single cells, presenting high electrochemical signal output and high specificity. This work not only provides a powerful tool for quantifying intracellular ATP but also offers a simple and versatile strategy for electrochemical signal amplification in the detection of broader non-electroactive molecules involved in different kinds of intracellular physiological processes.


Assuntos
Trifosfato de Adenosina , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Compostos Ferrosos , Ouro , Metalocenos , Trifosfato de Adenosina/análise , Aptâmeros de Nucleotídeos/química , Humanos , Ouro/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Metalocenos/química , Compostos Ferrosos/química , Técnicas Biossensoriais/métodos , Eletrodos , Polímeros/química , Nanofios/química , Limite de Detecção , Células HeLa
5.
Angew Chem Int Ed Engl ; : e202403241, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710651

RESUMO

Exocytosis involving the fusion of intracellular vesicles with cell membrane, is thought to be modulated by the mechanical cues in the microenvironment. Single-cell electrochemistry can offer unique information about the quantification and kinetics of exocytotic events; however, the effects of mechanical force on vesicular release have been poorly explored. Herein, we developed a stretchable microelectrode with excellent electrochemical stability under mechanical deformation by microfabrication of functionalized poly(3,4-ethylenedioxythiophene) conductive ink, which achieved real-time quantitation of strain-induced vesicular exocytosis from a single cell for the first time. We found that mechanical strain could cause calcium influx via the activation of Piezo1 channels in chromaffin cell, initiating the vesicular exocytosis process. Interestingly, mechanical strain increases the amount of catecholamines released by accelerating the opening and prolonging the closing of fusion pore during exocytosis. This work is expected to provide revealing insights into the regulatory effects of mechanical stimuli on vesicular exocytosis.

6.
Anal Chem ; 96(23): 9659-9665, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38798234

RESUMO

The intercellular communication of mechanotransduction has a significant impact on various cellular processes. Tunneling nanotubes (TNTs) have been documented to possess the capability of transmitting mechanical stimulation between cells, thereby triggering an influx of Ca2+ ions. However, the related kinetic information on the TNT-mediated intercellular mechanotransduction communication is still poorly explored. Herein, we developed a classic and sensitive Pt-functionalized carbon fiber microelectrochemical sensor (Pt/CF) to study the intercellular communication of endothelial mechanotransduction through TNTs. The experimental findings demonstrate that the transmission of mechanical stimulation from stimulated human umbilical vein endothelial cells (HUVECs) to recipient HUVECs connected by TNTs occurred quickly (<100 ms) and effectively promoted nitric oxide (NO) production in the recipient HUVECs. The kinetic profile of NO release exhibited remarkable similarity in stimulated and recipient HUVECs. But the production of NO in the recipient cell is significantly attenuated (16.3%) compared to that in the stimulated cell, indicating a transfer efficiency of approximately 16.3% for TNTs. This study unveils insights into the TNT-mediated intercellular communication of mechanotransduction.


Assuntos
Células Endoteliais da Veia Umbilical Humana , Mecanotransdução Celular , Nanotubos , Humanos , Nanotubos/química , Óxido Nítrico/metabolismo , Comunicação Celular , Técnicas Eletroquímicas , Técnicas Biossensoriais , Estruturas da Membrana Celular
7.
Anal Bioanal Chem ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38802680

RESUMO

Mechanotransduction is the essential process that cells convert mechanical force into biochemical responses, and electrochemical sensor stands out from existing techniques by providing quantitative and real-time information about the biochemical signals during cellular mechanotransduction. However, the intracellular biochemical response evoked by mechanical force has been poorly monitored. In this paper, we report a method to apply local stretch on single cell and simultaneously monitor the ensuing intracellular biochemical signals. Specifically, a ferromagnetic micropipette was fabricated to locally stretch a single cell labeled with Fe3O4 nanoparticles under the external magnetic field, and the SiC@Pt nanowire electrode (SiC@Pt NWE) was inserted into the cell to monitor the intracellular hydrogen peroxide (H2O2) production induced by the local stretch. As a proof of concept, this work quantitatively investigated the elevated amount of H2O2 levels in single endothelial cell under different stretching amplitudes. This work puts forward a new research modality to manipulate and monitor the mechanotransduction at the single-cell level.

8.
ACS Nano ; 18(8): 6176-6185, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38359155

RESUMO

Nanoplastics from air pollutants can be directly inhaled into the alveoli in the lungs and further enter blood circulation, and numerous studies have revealed the close relation between internalized nanoplastics with many physiological disorders via intracellular oxidative stress. However, the dynamic process of nanoplastics-induced oxidative stress in lung cells under breath-mimicked conditions is still unclear, due to the lack of methods that can reproduce the mechanical stretching of the alveolar and simultaneously monitor the oxidative stress response. Here, we describe a biomimetic platform by culturing alveoli epithelial cells on a stretchable electrochemical sensor and integrating them into a microfluidic device. This allows reproducing the respiration of alveoli by cyclic stretching of the alveoli epithelial cells and monitoring the nanoplastics-induced oxidative stress by the built-in sensor. By this device, we prove that cyclic stretches can greatly enhance the cellular uptake of nanoplastics with the dependencies of strain amplitude. Importantly, oxidative stress evoked by internalized nanoplastics can be quantitatively monitored in real time. This work will promote the deep understanding about the cytotoxicity of inhaled nanoplastics in the pulmonary mechanical microenvironment.


Assuntos
Células Epiteliais Alveolares , Microplásticos , Alvéolos Pulmonares , Pulmão , Estresse Oxidativo
9.
Nat Nanotechnol ; 19(4): 524-533, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38172432

RESUMO

Exposure to widely used inert fibrous nanomaterials (for example, glass fibres or carbon nanotubes) may result in asbestos-like lung pathologies, becoming an important environmental and health concern. However, the origin of the pathogenesis of such fibres has not yet been clearly established. Here we report an electrochemical nanosensor that is used to monitor and quantitatively characterize the flux and dynamics of reactive species release during the frustrated phagocytosis of glass nanofibres by single macrophages. We show the existence of an intense prolonged release of reactive oxygen and nitrogen species by single macrophages near their phagocytic cups. This continued massive leakage of reactive oxygen and nitrogen species damages peripheral cells and eventually translates into chronic inflammation and lung injury, as seen during in vitro co-culture and in vivo experiments.


Assuntos
Nanofibras , Nanotubos de Carbono , Oxigênio , Nanotubos de Carbono/química , Fagocitose , Macrófagos , Espécies Reativas de Oxigênio
10.
Angew Chem Int Ed Engl ; 62(51): e202313612, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37909054

RESUMO

The glutathione (GSH) system is one of the most powerful intracellular antioxidant systems for the elimination of reactive oxygen species (ROS) and maintaining cellular redox homeostasis. However, the rapid kinetics information (at the millisecond to the second level) during the dynamic antioxidation process of the GSH system remains unclear. As such, we specifically developed a novel dual-wire nanosensor (DWNS) that can selectively and synchronously measure the levels of GSH and ROS with high temporal resolution, and applied it to monitor the transient ROS generation as well as the rapid antioxidation process of the GSH system in individual cancer cells. These measurements revealed that the glutathione peroxidase (GPx) in the GSH system is rapidly initiated against ROS burst in a sub-second time scale, but the elimination process is short-lived, ending after a few seconds, while some ROS are still present in the cells. This study is expected to open new perspectives for understanding the GSH antioxidant system and studying some redox imbalance-related physiological.


Assuntos
Antioxidantes , Estresse Oxidativo , Antioxidantes/metabolismo , Espécies Reativas de Oxigênio , Glutationa/metabolismo , Oxirredução
11.
Angew Chem Int Ed Engl ; 62(43): e202309671, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37672359

RESUMO

Nanochannel technology has emerged as a powerful tool for label-free and highly sensitive detection of protein folding/unfolding status. However, utilizing the inner walls of a nanochannel array may cause multiple events even for proteins with the same conformation, posing challenges for accurate identification. Herein, we present a platform to detect unfolded proteins through electrical and optical signals using nanochannel arrays with outer-surface probes. The detection principle relies on the specific binding between the maleimide groups in outer-surface probes and the protein cysteine thiols that induce changes in the ionic current and fluorescence intensity responses of the nanochannel array. By taking advantage of this mechanism, the platform has the ability to differentiate folded and unfolded state of proteins based on the exposure of a single cysteine thiol group. The integration of these two signals enhances the reliability and sensitivity of the identification of unfolded protein states and enables the distinction between normal cells and Huntington's disease mutant cells. This study provides an effective approach for the precise analysis of proteins with distinct conformations and holds promise for facilitating the diagnoses of protein conformation-related diseases.

12.
Adv Mater ; : e2305917, 2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37639636

RESUMO

The rise of flexible and stretchable electronics has revolutionized biosensor techniques for probing biological systems. Particularly, flexible and stretchable electrochemical sensors (FSECSs) enable the in situ quantification of numerous biochemical molecules in different biological entities owing to their exceptional sensitivity, fast response, and easy miniaturization. Over the past decade, the fabrication and application of FSECSs have significantly progressed. This review highlights key developments in electrode fabrication and FSECSs functionalization. It delves into the electrochemical sensing of various biomarkers, including metabolites, electrolytes, signaling molecules, and neurotransmitters from biological systems, encompassing the outer epidermis, tissues/organs in vitro and in vivo, and living cells. Finally, considering electrode preparation and biological applications, current challenges and future opportunities for FSECSs are discussed.

13.
ACS Sens ; 8(8): 3248-3256, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37581426

RESUMO

Vascular smooth muscle cells (SMCs) are circumferentially oriented perpendicular to the blood vessel and maintain the contractile phenotype in physiological conditions. They can sense the mechanical forces of blood vessels expanding and contracting and convert them into biochemical signals to regulate vascular homeostasis. However, the real-time monitoring of mechanically evoked biochemical response while maintaining SMC oriented growth remains an important challenge. Herein, we developed a stretchable electrochemical sensor by electrospinning aligned and elastic polyurethane (PU) nanofibers on the surface of PDMS film and further modification of conductive polymer PEDOT:PSS-LiTFSI-CoPc (PPLC) on the nanofibers (denoted as PPLC/PU/PDMS). The aligned nanofibers on the electrode surface could guide the oriented growth of SMCs and maintain the contractile phenotype, and the modification of PPLC endowed the electrode with good electrochemical sensing performance and stability under mechanical deformation. By culturing cells on the electrode surface, the oriented growth of SMCs and real-time monitoring of stretch-induced H2O2 release were achieved. On this basis, the changes of H2O2 level released by SMCs under the pathology (hypertension) and intervention of natural product resveratrol were quantitatively monitored, which will be helpful to further understand the occurrence and development of vascular-related diseases and the mechanisms of pharmaceutical intervention.


Assuntos
Nanofibras , Peróxido de Hidrogênio , Mecanotransdução Celular , Miócitos de Músculo Liso , Poliuretanos , Eletrodos
14.
Anal Chem ; 95(34): 12859-12866, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37589391

RESUMO

Cardiomyocytes are responsible for generating contractile force to pump blood throughout the body and are very sensitive to mechanical forces and can initiate mechano-electric coupling and mechano-chemo-transduction. Remarkable progress has been made in constructing heart tissue by engineered three-dimensional (3D) culture models and in recording the electrical signals of cardiomyocytes. However, it remains a severe challenge for real-time acquiring of the transient biochemical information in cardiomyocyte mechano-chemo-transduction. Herein, we reported a multifunctional platform by integrating a 3D stretchable electrochemical sensor with collagen hydrogel for the culture, electrical stimulation, and electrochemical monitoring of cardiomyocytes. The 3D stretchable electrochemical sensor was prepared by assembling functionalized conductive polymer PEDOT:PSS on an elastic scaffold, which showed excellent electrochemical sensing performance and stability under mechanical deformations. The integration of a 3D stretchable electrochemical sensor with collagen hydrogel provided an in vivo-like microenvironment for cardiomyocyte culture and promoted cell orientation via in situ electrical stimulation. Furthermore, this multifunctional platform allowed real-time monitoring of stretch-induced H2O2 release from cardiomyocytes under their normal and pathological conditions, as well as pharmacological interventions.


Assuntos
Hidrogéis , Miócitos Cardíacos , Peróxido de Hidrogênio , Mecanotransdução Celular , Condutividade Elétrica
15.
iScience ; 26(7): 107130, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37456847

RESUMO

Hydrochlorothiazide (HCTZ) is reported to impair glucose tolerance and may induce new onset of diabetes, but the pharmacomicrobiomics of the adverse effect for HCTZ remains unknown. Mice-fed HCTZ exhibited insulin resistance and impaired glucose tolerance. By using FMT and antibiotic cocktail models, we found that HCTZ-induced metabolic disorder was mediated by commensal microbiota. HCTZ consumption disturbed the structure of the intestinal microbiota, causing abnormal elevation of Gram-negative Enterobacteriaceae and lipopolysaccharide (LPS) then leading to intestinal barrier dysfunction. Additionally, HCTZ activated TLR4 signaling and induced macrophage polarization and inflammation in the liver. Furthermore, HCTZ-induced macrophage polarization and metabolic disorder were abrogated by blocking TLR4 signaling. HCTZ consumption caused a significant increase in Gram-negative Enterobacteriaceae, which elevated the levels of LPS, thereby activating LPS/TLR4 pathway, promoting inflammation and macrophage polarization, and resulting in metabolic disorders. These findings revealed that the gut microbiome is the key medium underlying HCTZ-induced metabolic disorder.

17.
Int J Surg ; 109(8): 2500-2508, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37246971

RESUMO

STUDY OBJECTIVE: The role of transversus thoracic muscle plane blocks (TTMPBs) during cardiac surgery is controversial. We conducted a systematic review to establish the effectiveness of this procedure. DESIGN: Systematic review. We searched PubMed, Embase, Web of Science, CENTRAL, WanFang Data, and the China National Knowledge Infrastructure to June 2022, and followed the GRADE approach to evaluate the certainty of evidence. STUDY ELIGIBILITY CRITERIA: Eligible studies enrolled adult patients scheduled to undergo cardiac surgery and randomized them to receive a TTMPB or no block/sham block. MAIN RESULTS: Nine trials that enrolled 454 participants were included. Compared to no block/sham block, moderate certainty evidence found that TTMPB probably reduces postoperative pain at rest at 12 h [weighted mean difference (WMD) -1.51 cm on a 10 cm visual analogue scale for pain, 95% CI -2.02 to -1.00; risk difference (RD) for achieving mild pain or less (≤3 cm), 41%, 95% CI 17-65) and 24 h (WMD -1.07 cm, 95% CI -1.83 to -0.32; RD 26%, 95% CI 9-37). Moderate certainty evidence also supported that TTMPB probably reduces pain during movement at 12 h (WMD -3.42 cm, 95% CI -4.47 to -2.37; RD 46%, 95% CI 12-80) and at 24 h (WMD -1.73 cm, 95% CI -3.24 to -0.21; RD 32%, 95% CI 5-59), intraoperative opioid use [WMD -28 milligram morphine equivalent (MME), 95% CI -42 to -15], postoperative opioid consumption (WMD -17 MME, 95% CI -29 to -5), postoperative nausea and vomiting (absolute risk difference 255 less per 1000 persons, 95% CI 140-314), and intensive care unit (ICU) length of stay (WMD -13 h, 95% CI -21 to -6). CONCLUSION: Moderate certainty evidence showed TTMPB during cardiac surgery probably reduces postoperative pain at rest and with movement, opioid consumption, ICU length of stay, and the incidence of nausea and vomiting.


Assuntos
Analgésicos Opioides , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Analgésicos Opioides/uso terapêutico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Náusea e Vômito Pós-Operatórios , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Músculos
19.
Proc Natl Acad Sci U S A ; 120(19): e2219994120, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37126689

RESUMO

Glutamate (Glu) is the major excitatory transmitter in the nervous system. Impairment of its vesicular release by ß-amyloid (Aß) oligomers is thought to participate in pathological processes leading to Alzheimer's disease. However, it remains unclear whether soluble Aß42 oligomers affect intravesicular amounts of Glu or their release in the brain, or both. Measurements made in this work on single Glu varicosities with an amperometric nanowire Glu biosensor revealed that soluble Aß42 oligomers first caused a dramatic increase in vesicular Glu storage and stimulation-induced release, accompanied by a high level of parallel spontaneous exocytosis, ultimately resulting in the depletion of intravesicular Glu content and greatly reduced release. Molecular biology tools and mouse models of Aß amyloidosis have further established that the transient hyperexcitation observed during the primary pathological stage is mediated by an altered behavior of VGLUT1 responsible for transporting Glu into synaptic vesicles. Thereafter, an overexpression of Vps10p-tail-interactor-1a, a protein that maintains spontaneous release of neurotransmitters by selective interaction with t-SNAREs, resulted in a depletion of intravesicular Glu content, triggering advanced-stage neuronal malfunction. These findings are expected to open perspectives for remediating Aß42-induced neuronal hyperactivity and neuronal degeneration.


Assuntos
Doença de Alzheimer , Ácido Glutâmico , Camundongos , Animais , Ácido Glutâmico/metabolismo , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/metabolismo , Neurônios/metabolismo , Encéfalo/metabolismo , Fragmentos de Peptídeos/metabolismo
20.
iScience ; 26(3): 106089, 2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36876120

RESUMO

Oral squamous cell carcinoma (OSCC) is a common malignancy in the world. Recently, scientists have focused on therapeutic strategies to determine the regulation of tumors and design molecules for specific targets. Some studies have demonstrated the clinical significance of human leukocyte antigen G (HLA-G) in malignancy and NLR family pyrin domain-containing 3 (NLRP3) inflammasome in promoting tumorigenesis in OSCC. This is the first study to investigate whether aberrant epidermal growth factor receptor (EGFR) induces HLA-G expression through NLRP3 inflammasome-mediated IL-1ß secretion in OSCC. Our results showed that the upregulation of NLRP3 inflammasome leads to abundant HLA-G in the cytoplasm and cell membrane of FaDu cells. In addition, we also generated anti-HLA-G chimeric antigen receptor (CAR)-T cells and provided evidence for their effects in EGFR-mutated and overexpressed oral cancer. Our results may be integrated with OSCC patient data to translate basic research into clinical significance and may lead to novel EGFR-aberrant OSCC treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...