Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Clin Pharmacol ; 80(8): 1141-1150, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38605248

RESUMO

BACKGROUND: The efficacy and safety of direct oral anticoagulants (DOACs) in atrial fibrillation (AF) patients with impaired liver function (ILF) have not been sufficiently studied. The aim of this study was to evaluate the efficacy and safety of DOACs for stroke prevention in patients with AF and ILF. METHOD: This study was based on data from 15 centers in China, including 4,982 AF patients. The patients were divided into 2 subgroups based on their liver function status: patients with normal liver function (NLF)(n = 4213) and patients with ILF (n = 769). Logistic regression analysis was used to investigate the risk of total bleeding, major bleeding, thromboembolism, and all-cause deaths in AF patients with NLF and ILF after taking dabigatran or rivaroxaban, respectively. RESULTS: Among AF patients treated with dabigatran or rivaroxaban, patients with ILF were associated with significantly higher major bleeding, compared with NLF patients (aOR: 4.797; 95% CI: 2.224-10.256; P < 0.001). In patients with NLF, dabigatran (n = 2011) had considerably lower risk of total bleeding than rivaroxaban (n = 2202) (aOR: 1.23; 95% CI: 1.002-1.513; P = 0.049). In patients with ILF, dabigatran (n = 321) significantly favored lower risks of major bleeding compared with rivaroxaban(n = 448) (aOR: 5.484; 95% CI: 1.508-35.269; P = 0.026). CONCLUSION: After using dabigatran or rivaroxaban, patients with ILF had remarkably increased risk of major bleeding compared with patients with NLF. In AF patients with NLF, dabigatran had the distinct strength of significantly reduced risk of total bleeding compared with rivaroxaban. In patients with AF and ILF, dabigatran use was associated with lower risk for major bleeding compared with rivaroxaban.


Assuntos
Fibrilação Atrial , Dabigatrana , Hemorragia , Rivaroxabana , Humanos , Dabigatrana/efeitos adversos , Dabigatrana/uso terapêutico , Dabigatrana/administração & dosagem , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Rivaroxabana/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Masculino , Feminino , Idoso , Hemorragia/induzido quimicamente , Estudos Retrospectivos , Pessoa de Meia-Idade , Antitrombinas/efeitos adversos , Antitrombinas/uso terapêutico , Antitrombinas/administração & dosagem , Acidente Vascular Cerebral/prevenção & controle , Inibidores do Fator Xa/uso terapêutico , Inibidores do Fator Xa/efeitos adversos , Idoso de 80 Anos ou mais , Tromboembolia/prevenção & controle
2.
Entropy (Basel) ; 26(2)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38392356

RESUMO

The interior problem, a persistent ill-posed challenge in CT imaging, gives rise to truncation artifacts capable of distorting CT values, thereby significantly impacting clinical diagnoses. Traditional methods have long struggled to effectively solve this issue until the advent of supervised models built on deep neural networks. However, supervised models are constrained by the need for paired data, limiting their practical application. Therefore, we propose a simple and efficient unsupervised method based on the Cycle-GAN framework. Introducing an implicit disentanglement strategy, we aim to separate truncation artifacts from content information. The separated artifact features serve as complementary constraints and the source of generating simulated paired data to enhance the training of the sub-network dedicated to removing truncation artifacts. Additionally, we incorporate polar transformation and an innovative constraint tailored specifically for truncation artifact features, further contributing to the effectiveness of our approach. Experiments conducted on multiple datasets demonstrate that our unsupervised network outperforms the traditional Cycle-GAN model significantly. When compared to state-of-the-art supervised models trained on paired datasets, our model achieves comparable visual results and closely aligns with quantitative evaluation metrics.

3.
Med Phys ; 50(5): 2759-2774, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36718546

RESUMO

BACKGROUND: Many dedicated cone-beam CT (CBCT) systems have irregular scanning trajectories. Compared with the standard CBCT calibration, accurate calibration for CBCT systems with irregular trajectories is a more complex task, since the geometric parameters for each scanning view are variable. Most of the existing calibration methods assume that the intrinsic geometric relationship of the fiducials in the phantom is precisely known, and rarely delve deeper into the issue of whether the phantom accuracy is adapted to the calibration model. PURPOSE: A high-precision phantom and a highly robust calibration model are interdependent and mutually supportive, and they are both important for calibration accuracy, especially for the high-resolution CBCT. Therefore, we propose a calibration scheme that considers both accurate phantom measurement and robust geometric calibration. METHODS: Our proposed scheme consists of two parts: (1) introducing a measurement model to acquire the accurate intrinsic geometric relationship of the fiducials in the phantom; (2) developing a highly noise-robust nonconvex model-based calibration method. The measurement model in the first part is achieved by extending our previous high-precision geometric calibration model suitable for CBCT with circular trajectories. In the second part, a novel iterative method with optimization constraints based on a back-projection model is developed to solve the geometric parameters of each view. RESULTS: The simulations and real experiments show that the measurement errors of the fiducial ball bearings (BBs) are within the subpixel level. With the help of the geometric relationship of the BBs obtained by our measurement method, the classic calibration method can achieve good calibration based on far fewer BBs. All metrics obtained in simulated experiments as well as in real experiments on Micro CT systems with resolutions of 9 and 4.5 µm show that the proposed calibration method has higher calibration accuracy than the competing classic method. It is particularly worth noting that although our measurement model proves to be very accurate, the classic calibration method based on this measurement model can only achieve good calibration results when the resolution of the measurement system is close to that of the system to be calibrated, but our calibration scheme enables high-accuracy calibration even when the resolution of the system to be calibrated is twice that of the measurement system. CONCLUSIONS: The proposed combined geometrical calibration scheme does not rely on a phantom with an intricate pattern of fiducials, so it is applicable in Micro CT with high resolution. The two parts of the scheme, the "measurement model" and the "calibration model," prove to be of high accuracy. The combination of these two models can effectively improve the calibration accuracy, especially in some extreme cases.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Humanos , Calibragem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Microtomografia por Raio-X , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...