1.
J Neurophysiol ; 127(3): 651-659, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35020531

RESUMO

Heat/capsaicin sensitization and electrical high-frequency stimulation (HFS) are well-known models of secondary hyperalgesia, a phenomenon related to chronic pain conditions. This study investigated whether priming with heat/capsaicin would facilitate hyperalgesia to HFS in healthy subjects. Heat/capsaicin priming consisted of a 45°C heat stimulation for 5 min followed by a topical capsaicin patch (4 × 4 cm) for 30 min on the volar forearm of 20 subjects. HFS (100 Hz, 5 times 1 s, minimum 1.5 mA) was subsequently delivered through a transcutaneous pin electrode approximately 1.5 cm proximal to the heat/capsaicin application. Two sessions were applied in a crossover design; traditional HFS (HFS) and heat/capsaicin sensitization followed by HFS (HFS + HEAT/CAPS). Heat pain threshold (HPT), mechanical pain sensitivity (MPS), and superficial blood perfusion were assessed at baseline, after capsaicin removal, and up to 40 min after HFS. MPS was assessed with pin-prick stimulation (128 mN and 256 mN) in the area adjacent to both HFS and heat/capsaicin, distal but adjacent to heat/capsaicin and in a distal control area. HPT was assessed in the area of heat/capsaicin. Higher sensitivity to 128 mN pin-prick stimulation (difference from baseline and control area) was observed in the HFS + HEAT/CAPS session than in the HFS session 20 and 30 min after HFS. Furthermore, sensitivity was increased after HFS + HEAT/CAPS compared with after heat/capsaicin in the area adjacent to both paradigms, but not in the area distal to heat/capsaicin. Results indicate that heat/capsaicin causes priming of the central and peripheral nervous system, which facilitates secondary mechanical hyperalgesia to HFS.NEW & NOTEWORTHY High-frequency electrical stimulation (HFS) and heat/capsaicin sensitization are well-known models of secondary hyperalgesia. The results from the current study indicate that increased sensitivity to 128 mN pin-prick stimulation can be obtained when HFS is delivered following an already established heightened central hyperexcitability provoked by heat/capsaicin sensitization.


Assuntos
Capsaicina , Hiperalgesia , Capsaicina/farmacologia , Estimulação Elétrica , Temperatura Alta , Humanos , Dor , Limiar da Dor
2.
BMC Neurosci ; 20(1): 48, 2019 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-31521103

RESUMO

BACKGROUND: Electrical stimulation is widely used in experimental pain research but it lacks selectivity towards small nociceptive fibers. When using standard surface patch electrodes and rectangular pulses, large fibers are activated at a lower threshold than small fibers. Pin electrodes have been designed for overcoming this problem by providing a higher current density in the upper epidermis where the small nociceptive fibers mainly terminate. At perception threshold level, pin electrode stimuli are rather selectively activating small nerve fibers and are perceived as painful, but for high current intensity, which is usually needed to evoke sufficient pain levels, large fibers are likely co-activated. Long duration current has been shown to elevate the threshold of large fibers by the mechanism of accommodation. However, it remains unclear whether the mechanism of accommodation in large fibers can be utilized to activate small fibers even more selectively by combining pin electrode stimulation with a long duration pulse. RESULTS: In this study, perception thresholds were determined for a patch- and a pin electrode for different pulse shapes of long duration. The perception threshold ratio between the two different electrodes was calculated to estimate the ability of the pulse shapes to preferentially activate small fibers. The perception threshold ratios were compared between stimulation pulses of 5- and 50 ms durations and shapes of: exponential increase, linear increase, bounded exponential, and rectangular. Qualitative pain perception was evaluated for all pulse shapes delivered at 10 times perception threshold. The results showed a higher perception threshold ratio for long duration 50 ms pulses than for 5 ms pulses. The highest perception threshold ratio was found for the 50 ms, bounded exponential pulse shape. Results furthermore revealed different strength-duration relation between the bounded exponential- and rectangular pulse shapes. Pin electrode stimulation at high intensity was mainly described as "stabbing", "shooting", and "sharp". CONCLUSION: These results indicate that long duration pulses with a bounded exponential increase preferentially activate the small nociceptive fibers with a pin electrode and concurrently cause elevated threshold of large non-nociceptive fibers with patch electrodes.


Assuntos
Estimulação Elétrica/métodos , Fibras Nervosas/fisiologia , Limiar Sensorial/fisiologia , Pele/inervação , Adolescente , Adulto , Idoso , Eletrodos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
3.
BMC Neurosci ; 20(1): 47, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31481024

RESUMO

BACKGROUND: There is a need for new approaches to increase the knowledge of the membrane excitability of small nerve fibers both in healthy subjects, as well as during pathological conditions. Our research group has previously developed the perception threshold tracking technique to indirectly assess the membrane properties of peripheral small nerve fibers. In the current study, a new approach for studying membrane excitability by cooling small fibers, simultaneously with applying a slowly increasing electrical stimulation current, is evaluated. The first objective was to examine whether altered excitability during cooling could be detected by the perception threshold tracking technique. The second objective was to computationally model the underlying ionic current that could be responsible for cold induced alteration of small fiber excitability. The third objective was to evaluate whether computational modelling of cooling and electrical simulation can be used to generate hypotheses of ionic current changes in small fiber neuropathy. RESULTS: The excitability of the small fibers was assessed by the perception threshold tracking technique for the two temperature conditions, 20 °C and 32 °C. A detailed multi-compartment model was developed, including the ionic currents: NaTTXs, NaTTXr, NaP, KDr, KM, KLeak, KA, and Na/K-ATPase. The perception thresholds for the two long duration pulses (50 and 100 ms) were reduced when the skin temperature was lowered from 32 to 20 °C (p < 0.001). However, no significant effects were observed for the shorter durations (1 ms, p = 0.116; 5 ms p = 0.079, rmANOVA, Sidak). The computational model predicted that the reduction in the perception thresholds related to long duration pulses may originate from a reduction of the KLeak channel and the Na/K-ATPase. For short durations, the effect cancels out due to a reduction of the transient TTX resistant sodium current (Nav1.8). Additionally, the result from the computational model indicated that cooling simultaneously with electrical stimulation, may increase the knowledge regarding pathological alterations of ionic currents. CONCLUSION: Cooling may alter the ionic current during electrical stimulation and thereby provide additional information regarding membrane excitability of small fibers in healthy subjects and potentially also during pathological conditions.


Assuntos
Temperatura Baixa , Fibras Nervosas/fisiologia , Limiar Sensorial/fisiologia , Pele/inervação , Potenciais de Ação/fisiologia , Estimulação Elétrica , Feminino , Humanos , Masculino , Potenciais da Membrana/fisiologia , Modelos Neurológicos , Fatores de Tempo , Adulto Jovem
4.
J Neurophysiol ; 122(4): 1745-1752, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31461369

RESUMO

Electrical stimulation is widely used in pain research and profiling, but current technologies lack selectivity toward small sensory fibers. Pin electrodes deliver high current density in upper skin layers, and it has been proposed that slowly rising exponential pulses can elevate large-fiber activation threshold and thereby increase preferential small-fiber activation. Optimal stimulation parameters for the combined pin electrode and exponential pulse stimulation have so far not been established, which is the aim of this study. Perception thresholds were compared between pin and patch electrodes using single 1- to 100-ms exponential and rectangular pulses. Stimulus-response functions were evaluated for both pulse shapes delivered as single pulses and pulse trains of 10 Hz using intensities from 0.1 to 20 times perception threshold. Perception thresholds (mA) decreased when duration was increased for both electrodes with rectangular pulses and the pin electrode with exponential pulses. For the patch electrode, perception thresholds for exponential pulses decreased for durations ≤10 ms but increased for durations ≥15 ms, indicating accommodation of large fibers. Stimulus-response curves for single pulses were similar for the two pulse shapes. For pulse trains, the slope of the curve was higher for rectangular pulses. Maximal large-fiber accommodation to exponential pulses was observed for 100-ms pulses, indicating that 100-ms exponential pulses should be applied for preferential small-fiber activation. Intensity of 10 times perception threshold was sufficient to cause maximal pain ratings. The developed methodology may open new opportunities for using electrical stimulation paradigms for small-fiber stimulation and diagnostics.NEW & NOTEWORTHY Selective activation of small cutaneous nerve fibers is pivotal for investigations of the pain system. The present study demonstrated that patch electrode perception thresholds increase with increased duration of exponential currents from 20 to 100 ms. This is likely caused by large-fiber accommodation, which can be utilized to activate small fibers preferentially through small-diameter pin electrodes. This finding may be utilized in studies of fundamental pain mechanisms and, for example, in small-fiber neuropathy.


Assuntos
Axônios/fisiologia , Limiar Sensorial , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Feminino , Humanos , Masculino , Neurônios Aferentes/fisiologia , Percepção da Dor , Neuropatia de Pequenas Fibras/terapia , Estimulação Elétrica Nervosa Transcutânea/instrumentação
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 3488-91, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26737044

RESUMO

Individuals with high-level amputation have a great need for functional prostheses because of their vast functional deficits. Conventional techniques are considered inappropriate for high-level amputees due to the lack of physiologically appropriate muscles. This study investigates how accurate phantom movements (PMs) can be classified from physiologically inappropriate muscles. The study involves a case study of a 42-year-old transhumeral amputee. Suitable PMs and best electrode configuration were identified using the sequential forward selection method and brute-force technique. Using linear discriminant analysis, the best PMs (elbow extension/flexion, wrist supination/pronation) and rest were classified with error ranging from 3% to 0.18% when using 3 to 8 EMG channels respectively. A completion rate of 93 % was obtained during a targeted achievement control test in a virtual reality environment. This case indicates that a proximal transhumeral amputee can generate muscle activation patterns related to distinct PMs; and these PMs can be decoded from physiologically inappropriate muscles.


Assuntos
Amputados , Úmero/cirurgia , Movimento , Músculos/fisiopatologia , Imagens de Fantasmas , Adulto , Eletrodos , Eletromiografia , Humanos , Masculino
6.
Eur J Transl Myol ; 24(3): 4671, 2014 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-26913139

RESUMO

The project "Finger Rehabilitation" aims to design a neuroprosthesis with integrated electronics. The neuroprosthesis should enable spinal cord injured people, with injury at cervical vertebrae level, to increase finger mobility and activity with the use of functional electrical stimulation. The equipment is based on several integrated factors. The user has to be independent from any external help and has to be able to put it on, control the electrical stimulation and remove it by himself. The neuroprosthesis has to be both flexible and stable for the electrodes to remain firmly on the skin. In this part of the project, new electrodes which do not get stuck on the skin are described. The electrodes are small and have low impedance. A sleeve, made from glass fibres, is also described. The electrode matrices are integrated in the sleeve. The neuroprosthesis fits a patient with spinal cord injury at C5-C6. In this work, a novel electrode concept integrated in a glass fibre sleeve is tested on its ability for use in an "independent user" neuroprosthesis for finger movement rehabilitation.