Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(11)2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35684745

RESUMO

The sensing characteristics of toluene gas are monitored by fabricating ZnO nanorod structures. ZnO nanostructured sensor materials are produced on a Zn film via an ultrasonic process in a 0.01 M aqueous solution of C6H12N4 and Zn(NO3)2∙6H2O. The response of the sensors subjected to heat treatment in oxygen and nitrogen atmospheres is improved by 20% and 10%, respectively. The improvement is considered to be correlated with the increase in grain size. The relationship between the heat treatment and sensing characteristics is evaluated.


Assuntos
Nanoestruturas , Nanotubos , Óxido de Zinco , Temperatura Alta , Nanoestruturas/química , Nanotubos/química , Tolueno , Óxido de Zinco/química
2.
Sensors (Basel) ; 23(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36616663

RESUMO

Owing to the increasing construction of new buildings, the increase in the emission of formaldehyde and volatile organic compounds, which are emitted as indoor air pollutants, is causing adverse effects on the human body, including life-threatening diseases such as cancer. A gas sensor was fabricated and used to measure and monitor this phenomenon. An alumina substrate with Au, Pt, and Zn layers formed on the electrode was used for the gas sensor fabrication, which was then classified into two types, A and B, representing the graphene spin coating before and after the heat treatment, respectively. Ultrasonication was performed in a 0.01 M aqueous solution, and the variation in the sensing accuracy of the target gas with the operating temperature and conditions was investigated. As a result, compared to the ZnO sensor showing excellent sensing characteristics at 350 °C, it exhibited excellent sensing characteristics even at a low temperature of 150 °C, 200 °C, and 250 °C.


Assuntos
Poluentes Atmosféricos , Grafite , Óxido de Zinco , Humanos , Carbono , Óxido de Alumínio
3.
Environ Monit Assess ; 193(11): 751, 2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34704116

RESUMO

Numerous studies have reported that CO2 emissions have decreased because of global lockdown during the first wave of the COVID-19 pandemic. However, previous estimates of the global CO2 concentration before and after the outbreak of the COVID-19 pandemic are limited because they are based on energy consumption statistics or local specific in-situ observations. The aim of the study was to explore objective evidence for various previous studies that have claimed the global CO2 concentration decreased during the first wave of the COVID-19 pandemic. There are two ways to measure the global CO2 concentration: from the top-down using satellites and the bottom-up using ground stations. We implemented the time-series analysis by comparing the before and after the inflection point (first wave of COVID-19) with the long-term CO2 concentration data obtained from World Meteorological Organization Global Atmosphere Watch (WMO GAW) and Greenhouse Gases Observing Satellite (GOSAT). Measurements from the GOSAT and GAW global monitoring stations show that the CO2 concentrations in Europe, China, and the USA have continuously risen in March and April 2020 compared with the same months in 2019. These data confirm that the global lockdown during the first wave of the COVID-19 pandemic did not change the vertical CO2 profile at the global level from the ground surface to the upper layer of the atmosphere. The results of this study provide an important foundation for the international community to explore policy directions to mitigate climate change in the upcoming post-COVID-19 period.


Assuntos
COVID-19 , Dióxido de Carbono , Dióxido de Carbono/análise , Controle de Doenças Transmissíveis , Monitoramento Ambiental , Humanos , Pandemias , SARS-CoV-2
4.
J Nanosci Nanotechnol ; 20(11): 7169-7174, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32604577

RESUMO

SnO2 thin-film gas sensors were easily created using the ion sputtering technique. The as-deposited SnO2 thin films consist of a tetragonal SnO2 phase and densely packed nanosized grains with diameters of approximately 20-80 nm, which are separated by microcracks. The as-deposited SnO2 thin film is well crystallized, with a dense columnar nanostructure grown directly onto the alumina material and the Pt electrodes. The grain size and thickness of SnO2 thin films are easily controlled by varying the sputtering time of the ion coater. The responses of the SnO2 thin-film sensors decrease as the SnO2 film thickness is increased, indicating that a negative association exists between the sensor response and the SnO2 film thickness due to gas diffusion from the surface. The SnO2 thin-film sensor, which was created by ion sputtering for 10 min, shows an excellent sensor response (Ra/Rg where Ra is the electric resistance under air and Rg is the electric resistance under the test gas) for detecting 1 ppm H2S at 350°C.

5.
Sensors (Basel) ; 17(8)2017 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-28771180

RESUMO

Exhaled breath is a body secretion, and the sampling process of this is simple and cost effective. It can be non-invasively collected for diagnostic procedures. Variations in the chemical composition of exhaled breath resulting from gaseous exchange in the extensive capillary network of the body are proposed to be associated with pathophysiological changes. In light of the foreseeable potential of exhaled breath as a diagnostic specimen, we used gas chromatography and mass spectrometry (GC-MS) to study the chemical compounds present in exhaled breath samples from patients with Alzheimer's disease (AD), Parkinson's disease (PD), and from healthy individuals as a control group. In addition, we also designed and developed a chemical-based exhaled breath sensor system to examine the distribution pattern in the patient and control groups. The results of our study showed that several chemical compounds, such as 1-phenantherol and ethyl 3-cyano-2,3-bis (2,5,-dimethyl-3-thienyl)-acrylate, had a higher percentage area in the AD group than in the PD and control groups. These results may indicate an association of these chemical components in exhaled breath with the progression of disease. In addition, in-house fabricated exhaled breath sensor systems, containing several types of gas sensors, showed significant differences in terms of the normalized response of the sensitivity characteristics between the patient and control groups. A subsequent clustering analysis was able to distinguish between the AD patients, PD patients, and healthy individuals using principal component analysis, Sammon's mapping, and a combination of both methods, in particular when using the exhaled breath sensor array system A consisting of eight sensors. With this in mind, the exhaled breath sensor system could provide alternative option for diagnosis and be applied as a useful, effective tool for the screening and diagnosis of AD in the near future.


Assuntos
Expiração , Doença de Alzheimer , Testes Respiratórios , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Doença de Parkinson , Compostos Orgânicos Voláteis
6.
Tissue Eng Regen Med ; 13(1): 13-20, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30603380

RESUMO

Growth factors play multiple and critical roles in wound repair processes. Platelet-derived growth factor (PDGF) is a potent growth factor that is particularly important in the early inflammatory phase of wound healing. In order to extend the half-life of PDGF, polymeric encapsulation is used. In the current study, Poly (lactic-co-glycolic acid) (PLGA) microspheres containing recombinant human (rh) PDGF-BB were prepared to prolong the effectiveness of this growth factor. PLGA microspheres were optimized using a modified w/o/w-double-emulsion/solvent evaporation method by changing the processing conditions of stirring speed and emulsifier (polyvinyl alcohol) concentration. Microspheres prepared using the optimized method released rhPDGF-BB for up to three weeks. An in vitro migration assay showed a significant decrease in the wound area in cells treated with rhPDGF-BB microspheres compared to control cells. These findings demonstrate the potential of rhPDGF-BB encapsulated in microspheres to enhance wound healing.

7.
Tissue Eng Regen Med ; 13(1): 31-38, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30603382

RESUMO

Full skin auto-grafts are required for reconstruction of skin burns and trauma scars. However, currently available clinical approaches such as sheet skin graft, mesh skin grafts, artificial skin graft, and in vivo skin expansion have limitations due to their potential danger for secondary damage and scar formation at the donor site, and discomfort during skin expansion. We developed an advanced bioreactor system and evaluated its function in skin expansion using porcine full skin. The reactor was designed as a pneumatic cylinder type, was programmed to adjust the pressure and the operating time. The system was composed of culture chamber unit, environmental control unit, and monitoring unit. Skins were expanded at 200 kPa pneumatic force and the expanded skins were analyzed by immunohistochemistry and histology. Furthermore we carried out auto-grafting experiment of the expanded skins in vivo using Yucatan pigs and skins were harvested and histologically analyzed after 8 weeks. The results showed that the bioreactor expanded skins to 160% in 4 hours. Histological analysis of the expanded skins revealed that epidermal cells and dermal fibroblasts were viable and remained integrity. The results of auto-grafting experiment indicated that fibrosis and scars were not detected in the grafted skins. This study demonstrates that the newly developed skin bioreactor enabled to obtain large sized full skin rapidly and successful grating.

8.
PLoS One ; 10(2): e0117810, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25714733

RESUMO

Body fluids are often used as specimens for medical diagnosis. With the advent of advanced analytical techniques in biotechnology, the diagnostic potential of saliva has been the focus of many studies. We recently reported the presence of excess salivary sugars, in patients with Alzheimer's disease (AD). In the present study, we developed a highly sensitive, cell-based biosensor to detect trehalose levels in patient saliva. The developed biosensor relies on the overexpression of sugar sensitive gustatory receptors (Gr5a) in Drosophila cells to detect the salivary trehalose. The cell-based biosensor was built on the foundation of an improved extended gate ion-sensitive field-effect transistor (EG-ISFET). Using an EG-ISFET, instead of a traditional ion-sensitive field-effect transistor (ISFET), resulted in an increase in the sensitivity and reliability of detection. The biosensor was designed with the gate terminals segregated from the conventional ISFET device. This design allows the construction of an independent reference and sensing region for simultaneous and accurate measurements of samples from controls and patients respectively. To investigate the efficacy of the cell-based biosensor for AD screening, we collected 20 saliva samples from each of the following groups: participants diagnosed with AD, participants diagnosed with Parkinson's disease (PD), and a control group composed of healthy individuals. We then studied the response generated from the interaction of the salivary trehalose of the saliva samples and the Gr5a in the immobilized cells on an EG-ISFET sensor. The cell-based biosensor significantly distinguished salivary sugar, trehalose of the AD group from the PD and control groups. Based on these findings, we propose that salivary trehalose, might be a potential biomarker for AD and could be detected using our cell-based EG-ISFET biosensor. The cell-based EG-ISFET biosensor provides a sensitive and direct approach for salivary sugar detection and may be used in the future as a screening method for AD.


Assuntos
Doença de Alzheimer/diagnóstico , Técnicas Biossensoriais , Metabolismo dos Carboidratos , Proteínas de Drosophila/genética , Expressão Gênica , Receptores de Superfície Celular/genética , Saliva/metabolismo , Idoso , Animais , Biomarcadores , Estudos de Casos e Controles , Linhagem Celular , Proteínas de Drosophila/metabolismo , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Receptores de Superfície Celular/metabolismo , Sensibilidade e Especificidade , Trealose/metabolismo
9.
J Nanosci Nanotechnol ; 14(11): 8518-22, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25958556

RESUMO

Liquid-phase exfoliation is likely to be feasible for practical fabrication of few-layer MoS2 nanosheets in large quantities. However, this method generally involves the organic solvents with high boiling point; new strategy using low-boiling-point solvents to obtain high MoS2 concentration is still highly required. In this study, using the strategy of Hansen solubility parameters (HSP), a method based on exfoliation of MoS2 in chloroform/acetonitrile mixtures is demonstrated to fabricate high concentration MoS2 nanosheet solution. The highest concentration of few-layer MoS2 nanosheets and nanoparticles up to 0.4 mg/ml is achieved with the optimum composition of mixture. The MoS2 nanosheet thin film is also investigated in terms of their sensing properties towards humidity. The exfoliated MoS2 based thin film sensor exhibited excellent sensitivity, quick response and recovery, and good reproducibility comparing to their bulk counterpart. The excellent sensing performance of exfoliated MoS2 is generally attributed to the high surface-to-volume-ratio and increased ratio of edge sites and basal plane sites after exfoliation.

10.
J Nanosci Nanotechnol ; 12(2): 1521-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22629992

RESUMO

Controlled synthesis of ZnO nanorods (ZNRDs), nanotubes (ZNTs) and nanorings (ZNRs) has been carried out by a two-step sonochemical/chemical process at room temperature without any catalyst, template or seed layer. The crystallinity, structure and morphology of ZNRDs, ZNRs and ZNTs were examined by X-ray diffraction (XRD) analysis, scanning electron micrographs (SEM), high resolution transmission electron microscope (HR-TEM) and selected area electron diffraction (SAED). The as-prepared ZnO nanostructures were single crystalline with hexagonal cross-section and uniform size. The effect of precursor concentration on the growth and that of the etching duration on the hollow formation were analyzed, and the obtained results revealed that the precursor concentration and etching time play an important role in determining final morphologies of the samples. By tuning the etching time, the precise size control of ZNTs and ZNRs was achieved. Possible formation mechanisms of these nanostructures are proposed based on the experimental results.

11.
Int J Pharm ; 384(1-2): 120-7, 2010 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-19819316

RESUMO

Microencapsulation of drugs into solid biodegradable polymeric microspheres via solvent evaporation technique remains challenging especially with those having low molecular weight and high hydrophilicity nature. This paper presents an efficient encapsulation protocol for this group of drugs, demonstrated using hydrogen peroxide as a model compound that is encapsulated into poly(lactic-co-glycolic acid) microspheres. Hydrogen peroxide can be employed as antiseptic agent or its decomposed form into oxygen can be useful in various pharmaceutical applications. The new encapsulation technique was developed based on the modification of conventional double emulsion and solvent evaporation protocol with a backward concentration gradient of hydrogen peroxide. This was achieved by adding and controlling the concentration of hydrogen peroxide at the continuous phase during the solidification stage of the microspheres. Parameters involved in the production and the formulation aspect were optimized to achieve the best protocol having controlled efficiency of encapsulation that is simple, safe, practical, and economical. Evaluation on the encapsulation efficiency and the release profile has been made indirectly by monitoring the dissolved oxygen level of the solution where the microspheres were incubated. Morphology of the microspheres was investigated using scanning electron microscopy. This proposed method has successfully used to prepare batches of microspheres having different encapsulation efficiencies and its potential applications have been demonstrated accordingly.


Assuntos
Química Farmacêutica/métodos , Peróxido de Hidrogênio/síntese química , Água , Animais , Linhagem Celular Tumoral , Composição de Medicamentos , Ácido Láctico/síntese química , Camundongos , Peso Molecular , Ácido Poliglicólico/síntese química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...