Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Haemophilia ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38812123

RESUMO

INTRODUCTION: In patients with an increased bleeding tendency, extensive diagnostic blood testing is often performed. When results of tier 1 assays of primary haemostasis are normal, protocols recommend additional testing to rule out rare disorders including coagulation factor XIII (FXIII) and α2-antiplasmin (α2AP) deficiency. AIM: To evaluate the added diagnostic value of FXIII and α2AP levels in patients with a bleeding disorder of unknown cause (BDUC). METHODS: A retrospective monocentre cohort study between August 2011 and August 2023 was conducted. In all patients with bleeding tendencies and normal diagnostic tests for von Willebrand disease and platelet function, FXIII and α2AP were measured. RESULTS: We included 158 consecutive patients; mean ISTH-BAT scores were 8.2 (SD ± 3.7) in children, 6.2 (SD ± 2.1) in men and 10.6 (SD ± 3.3) in women. Median age was 37 (range 5-79) years, 88.6% of patients were female. Patients displayed median FXIII activity of 111% (IQR = 97-131) and median α2AP activity of 112% (IQR = 103-119). Three (1.9%) patients had FXIII levels < 50%, respectively 43%, 45% and 46%. Corresponding ISTH-BAT scores were 7, 12 and 14. No α2AP levels < 60% was observed. No significant association was found between FXIII levels and ISTH-BAT scores. CONCLUSION: In our cohort of BDUC patients, no clinical relevant FXIII deficiencies were detected; absolute values were well above the 30% cutoff considered adequate for normal haemostasis. No α2AP deficiencies were detected. These data suggest that in BDUC patients, measuring FXIII or AP activity is of limited value.

3.
Res Pract Thromb Haemost ; 7(7): 102229, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38077824

RESUMO

Background: Heavy menstrual bleeding (HMB), self-reported by 37% of adolescents, can be the first sign of a bleeding disorder (BD) during adolescence. The Dutch general practitioner (GP) guideline demands laboratory diagnostics and referral for patients at risk for a BD. How often adolescents consult the GP for HMB and which diagnostic and management strategies are used are unknown. Objectives: This study aims to estimate the incidence of HMB in adolescents in primary care and to identify diagnostic and management practices for HMB, considering the HMB GP guideline. Methods: Retrospective analyses of a GP network database containing over 200 Dutch GPs were performed. Adolescents aged 10 to 21 years, with a new diagnosis of HMB between 2010 and 2020, and a 6-month follow-up were eligible. The incidence rate and diagnostic and therapeutic strategy data were extracted. Results: We identified 1879 new diagnoses of HMB in adolescents. The average incidence rate was 7.91 per 1000 person-years. No diagnostic studies were performed in 67%. Laboratory studies were mainly restricted to hemoglobin levels (31%). Full coagulation screening occurred in 1.3%, and ferritin levels in 10%. Medication was prescribed in 65%; mostly hormonal treatment (56%) and/or nonsteroidal antiinflammatory drugs (NSAIDs) (18%). The referral rate was higher after >2 follow-up visits (6.7%) vs after 1 GP visit for HMB (1.6%; Odds ratio: 8.8; 95% CI: 5.1-15), mostly to gynecologists (>85%). Conclusion: According to this GP database study, few adolescents visit their GP with HMB despite its high self-reported incidence. Most adolescents were prescribed hormonal contraception without further diagnostics. Referral was rare and mostly occurred after multiple follow-up visits.

4.
Int J Lab Hematol ; 45(6): 869-874, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37571820

RESUMO

INTRODUCTION: Hemoglobin-based oxygen carriers, for example HBOC-201 (Hemopure), are aimed to bridge acute anemia when blood transfusion is not available or refused by the patient. However, since HBOC-201 appears free in plasma, it interferes with laboratory tests. This study presents an overview of HBOC-201 interference on four commonly used hematology analyzers and suggests treatment monitoring possibilities. METHODS: Blood samples were spiked with therapeutic doses of HBOC-201 and nine hematology parameters were measured with the Sysmex XN-20, Siemens Advia 2120i, Abbott Alinity Hq and Abbot Cell Dyn Sapphire hematology analyzers. The results were compared to control samples and the bias was determined. RESULTS: Most parameters, including all cell counts, hematocrit and MCV, showed a non-significant bias compared to control. However, the standard, total hemoglobin (Hb) measurement as well as MCH and MCHC showed poor agreement with control, as HBOC-201 was included in this measurement. Yet, the flow cytometry-based Hb method quantified intracellular Hb in spiked samples, excluding HBOC-201. CONCLUSION: Of all included hematology parameters, only total Hb and the associated MCH and MCHC suffered from interference. In contrast, the flow cytometry-based Hb measurement provided an accurate measure of intracellular Hb. The difference between total Hb and cellular Hb represents the HBOC-201 concentration and can be used to monitor HBOC-201 treatment.


Assuntos
Hematologia , Hemoglobinas , Humanos , Hemoglobinas/análise , Testes Hematológicos , Transfusão de Sangue , Oxigênio
5.
Clin Appl Thromb Hemost ; 29: 10760296231183427, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37322895

RESUMO

Even though routine screening of the general hospital population is discouraged, medical laboratories may use a "lupus sensitive" activated partial thromboplastin time test (aPTT) with phospholipid concentrations that are susceptible to inhibition by lupus anticoagulant (LA), to screen for the presence of LA. If deemed necessary, follow-up testing according to ISTH guidelines may be performed. However, LA testing is a laborious and time-consuming effort that is often not readily available due to a lack of automation and/or temporary unavailability of experienced staff. In contrast, the aPTT is a fully automated test that is available 24/7 in almost all medical laboratories and is easily interpreted with the use of reference ranges. In addition to clinical signs, the result of an LA sensitive aPTT may thus be used to lower the suspicion of the presence of LA and reduce costly follow-up testing. In this study, we show that a normal LA sensitive aPTT result may be safely used to refrain from LA testing in the absence of strong clinical suspicion.


Assuntos
Síndrome Antifosfolipídica , Inibidor de Coagulação do Lúpus , Humanos , Tempo de Tromboplastina Parcial , Testes de Coagulação Sanguínea , Valores de Referência
6.
Sci Rep ; 13(1): 9223, 2023 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-37286717

RESUMO

Red blood cell distribution width (RDW) is a biomarker associated with a variety of clinical outcomes. While anemia and subclinical inflammation have been posed as underlying pathophysiology, it is unclear what mechanisms underlie these assocations. Hence, we aimed to unravel the mechanisms in silico using a large clinical dataset and validate our findings in vitro. We retrieved complete blood counts (CBC) from 1,403,663 measurements from the Utrecht Patient Oriented Database, to model RDW using gradient boosting regression. We performed (sex-stratified) analyses in patients with anemia, patients younger/older than 50 and validation across platforms and care settings. We then validated our hypothesis regarding oxidative stress using an in vitro approach. Only percentage microcytic (pMIC) and macrocytic (pMAC) erythrocytes and mean corpuscular volume were most important in modelling RDW (RMSE = 0.40, R2 = 0.96). Subgroup analyses and validation confirmed our findings. In vitro induction of oxidative stress underscored our results, namely increased RDW and decreased erythrocyte volume, yet no vesiculation was observed. We found that erythrocyte size, especially pMIC, is most informative in predicting RDW, but no role for anemia or inflammation. Oxidative stress affecting the size of the erythrocytes may play a role in the association between RDW and clinical outcomes.


Assuntos
Anemia , Eritrócitos , Humanos , Índices de Eritrócitos , Inflamação , Estresse Oxidativo
7.
Int J Lab Hematol ; 45(5): 659-667, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37128804

RESUMO

INTRODUCTION: This study assessed the comparability of complete blood count (CBC) parameters between capillary and venous samples, and extended previous research by examining the influence of different storage temperatures on CBC stability up to 7 days after sample collection. METHODS: Venous and capillary blood samples were collected from 93 adult patients. Hemoglobin (Hb), hematocrit (Ht), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), mean platelet volume (MPV), leukocytes, lymphocytes, basophils, eosinophils, erythrocytes, red cell distribution width (RDW), immature granulocytes (IG), immature reticulocyte fraction (IRF), monocytes, neutrophils, platelets, and reticulocytes were measured. Deming regression and mean relative differences between venous and capillary measurements were contrasted with desirable total allowable error (TEa). Stability was assessed in 20-27 venous blood samples stored at 4, 21-22, or 30°C, and analyzed at 0, 24, 48, 72, 96, 120, 144, and 168 h. Mean relative change with respect to baseline measurements was compared to the desirable TEa to determine acceptable stability. RESULTS: Deming regression demonstrated strong linear correlations and acceptable variation between venous and capillary measurements. Erythrocytes, Hb, Ht, MCH, MCV, RDW, reticulocytes, and platelets showed acceptable stability for at least 96 h at 4°C. Mean relative change exceeded desirable TEa after 24 h at 30°C for all parameters, except erythrocytes, Hb, leukocytes, and MCH. CONCLUSION: Clinical laboratory specialists and clinicians should be aware of potential differences between venous and capillary measurements, and the influence of storage conditions. Clinical validity of delayed CBC analysis depends on the clinical situation and required precision of the result.


Assuntos
Índices de Eritrócitos , Eritrócitos , Adulto , Humanos , Contagem de Células Sanguíneas/métodos , Hematócrito , Eritrócitos/química , Hemoglobinas/análise , Eosinófilos
8.
Ned Tijdschr Geneeskd ; 1672023 04 19.
Artigo em Holandês | MEDLINE | ID: mdl-37078569

RESUMO

This commentary discusses the prevalence and causes of anemia in primary care in the Netherlands and the role of laboratory diagnostics in determining the cause of anemia. There are indications that guidelines in primary care regarding anemia are insufficiently followed; there are also indications that the correct laboratory measurements are requested too limited (under-diagnosis). A possible solution lies in the introduction of reflective testing, in which the laboratory specialist has additional diagnostic laboratory tests performed on the basis of the laboratory results and specific characteristics of the patient. Reflective testing is in contrast to reflex testing; in reflex testing, laboratory measurements are added automatically using a simple flowchart. In the future, Artificial Intelligence solutions could play a role in determining the most optimal laboratory diagnostic strategy for the diagnosis of anemia in primary care.


Assuntos
Anemia , Inteligência Artificial , Humanos , Anemia/diagnóstico , Anemia/etiologia , Reflexo , Algoritmos , Atenção Primária à Saúde
9.
Res Pract Thromb Haemost ; 7(1): 100011, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36891523

RESUMO

Background: Patients with antiphospholipid syndrome (APS) receive anticoagulant therapy with vitamin K antagonists (VKAs) to prevent recurrent thrombosis. VKA treatment requires strict monitoring with an international normalized ratio (INR). It is known that lupus anticoagulants (LAs) can lead to elevated INR results with point-of-care-testing (POCT) devices, which could result in inadequate adaptation of anticoagulant therapy. Objective: To determine discrepancies between POCT-INR and laboratory-INR in patients who are LA-positive on VKA therapy. Methods: Paired INR testing was performed with 1 POCT device (CoaguChek XS) and 2 laboratory assays (Owren and Quick method) in 33 patients with LA-positive APS on VKA in a single-center cross-sectional study. Patients were tested for anti-ß2-glycoprotein I, anticardiolipin, and antiphosphatidylserine/prothrombin immunoglobulin (Ig) G and IgM antibodies. Agreement between assays was evaluated with Spearman's correlation, Lin's correlation coefficient, and Bland-Altman plots. Agreement limits were considered satisfactory if differences were ≤20% as determined by the Clinical and Laboratory Standards Institute. Results: We found poor agreement between POCT-INR and laboratory-INR based on Lin's concordance correlation coefficient (ρc) of 0.42 (95% CI, 0.26-0.55) between POCT-INR and Owren-INR, a ρc of 0.64 (95% CI, 0.47-0.76) between POCT-INR and Quick-INR, and a ρc of 0.77 (95% CI, 0.64-0.85) between Quick-INR and Owren-INR. High anti-ß2-glycoprotein I IgG antibody titers correlated with INR disagreement between POCT-INR and laboratory-INR. Conclusion: There is a disagreement between INR values measured with the CoaguChek XS and laboratory-INR in a proportion of patients with LA. Consequently, laboratory-INR monitoring should be preferred over POCT-INR monitoring in patients with LA-positive APS, especially in patients with high anti-ß2-glycoprotein IgG antibody titers.

10.
ASAIO J ; 69(5): 438-444, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730294

RESUMO

Thrombus formation is a common complication during left ventricular assist device (LVAD) therapy, despite anticoagulation with vitamin K antagonists (VKA) and a platelet inhibitor. Plasma levels of markers for primary and secondary hemostasis and contact activation were determined before LVAD implantation and 6 and 12 months thereafter in 37 adults with end-stage heart failure. Twelve patients received a HeartMate 3, 7 patients received a HeartWare, and 18 patients received a HeartMate II. At baseline, patients had elevated plasma levels of the platelet protein upon activation, ß-thromboglobulin, and active von Willebrand factor in thrombogenic state (VWFa), which remained high after LVAD implantation. Von Willebrand factor levels and VWF activity were elevated at baseline but normalized 12 months after LVAD implantation. High D -dimer plasma levels, at baseline, remained elevated after 12 months. This was associated with an increase in plasma thrombin-antithrombin-complex levels and plasma levels of contact activation marker-cleaved H-kininogen after LVAD implantation. Considering these results it could be concluded that LVAD patients show significant coagulation activation despite antithrombotic therapy, which could explain why patients are at high risk for LVAD-induced thrombosis. Continuous low-grade systemic platelet activation and contact activation may contribute to prothrombotic effects of LVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Adulto , Humanos , Fator de von Willebrand/metabolismo , Coração Auxiliar/efeitos adversos , Hemostasia , Coagulação Sanguínea , Trombose/etiologia , Insuficiência Cardíaca/terapia
11.
Am J Hum Genet ; 110(1): 146-160, 2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36608681

RESUMO

Neddylation has been implicated in various cellular pathways and in the pathophysiology of numerous diseases. We identified four individuals with bi-allelic variants in NAE1, which encodes the neddylation E1 enzyme. Pathogenicity was supported by decreased NAE1 abundance and overlapping clinical and cellular phenotypes. To delineate how cellular consequences of NAE1 deficiency would lead to the clinical phenotype, we focused primarily on the rarest phenotypic features, based on the assumption that these would best reflect the pathophysiology at stake. Two of the rarest features, neuronal loss and lymphopenia worsening during infections, suggest that NAE1 is required during cellular stress caused by infections to protect against cell death. In support, we found that stressing the proteasome system with MG132-requiring upregulation of neddylation to restore proteasomal function and proteasomal stress-led to increased cell death in fibroblasts of individuals with NAE1 genetic variants. Additionally, we found decreased lymphocyte counts after CD3/CD28 stimulation and decreased NF-κB translocation in individuals with NAE1 variants. The rarest phenotypic feature-delayed closure of the ischiopubic rami-correlated with significant downregulation of RUN2X and SOX9 expression in transcriptomic data of fibroblasts. Both genes are involved in the pathophysiology of ischiopubic hypoplasia. Thus, we show that NAE1 plays a major role in (skeletal) development and cellular homeostasis during stress. Our approach suggests that a focus on rare phenotypic features is able to provide significant pathophysiological insights in diseases caused by mutations in genes with pleiotropic effects.


Assuntos
Deficiência Intelectual , Linfopenia , Humanos , Proteína NEDD8/genética , Proteína NEDD8/metabolismo , Transdução de Sinais/genética , Deficiência Intelectual/genética , NF-kappa B/metabolismo , Complexo de Endopeptidases do Proteassoma/metabolismo , Linfopenia/genética
12.
J Thromb Haemost ; 21(4): 1020-1031, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36696209

RESUMO

BACKGROUND: Thrombopoietin receptor agonists are frequently used in treating immune thrombocytopenia (ITP) owing to high response rates and good tolerability. ITP is associated with an increased risk of thrombosis. Whether treatment with eltrombopag further increases this risk is controversial. The mechanisms behind the thrombotic risk in ITP are unclear. OBJECTIVES: To assess platelet function and hypercoagulability in patients with ITP and the effect of eltrombopag thereon. METHODS: This prospective multicenter study assessed adult primary patients with ITP who were starting eltrombopag treatment. Platelet (re)activity and hypercoagulability were measured in whole blood or plasma before start and after 2 to 3 weeks of eltrombopag treatment and compared with those of controls. Change over time was assessed by mixed-effects models, and the results were corrected for multiple testing. RESULTS: We included 16 patients and 33 controls. At baseline, patients with ITP exhibited lower expression of glycoprotein VI, more activated platelets, and lower reactivity toward agonists compared with controls. ß-Thromboglobulin levels reduced and thrombin generation peak height increased compared with those of controls. In line with this finding, patients with ITP showed high factor VIII (median, 217%; IQR, 174%-272%) and von Willebrand factor levels (median, 167%; IQR, 109%-198%). Eltrombopag treatment increased thrombin generation potential: lag time decreased and peak height and endogeneous thrombin potential increased. The latter changes were not significant after correction for multiple testing. CONCLUSION: Patients with ITP in this study were in a hypercoagulable state, with preactivated platelets, increased thrombin generation potential, and increased levels of factor VIII and von Willebrand factor. Eltrombopag treatment further increased plasma thrombin generation potential but no other hemostatic parameters.


Assuntos
Púrpura Trombocitopênica Idiopática , Trombocitopenia , Trombofilia , Adulto , Humanos , Púrpura Trombocitopênica Idiopática/diagnóstico , Púrpura Trombocitopênica Idiopática/tratamento farmacológico , Púrpura Trombocitopênica Idiopática/induzido quimicamente , Estudos Prospectivos , Fator VIII , Trombina , Fator de von Willebrand , Hidrazinas/efeitos adversos , Trombofilia/induzido quimicamente
13.
Res Pract Thromb Haemost ; 6(4): e12725, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35702589

RESUMO

Background: Emicizumab is a new treatment option for people with hemophilia A. Emicizumab was approved with a body-weight-based dosage regimen, without laboratory monitoring requirements. Guidelines, however, recommend measuring emicizumab concentrations when the presence of antidrug antibodies is suspected. Furthermore, drug monitoring can be useful in clinical decision making, in adherence checking, and for research purposes. Therefore, we developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying emicizumab. We performed a validation study on this LC-MS/MS method quantifying emicizumab in the plasma of people with hemophilia A. Methods: Sample preparation for LC-MS/MS analysis included ammonium sulfate protein precipitation and trypsin digestion. A signature peptide of emicizumab and a matching stable isotope-labeled internal standard were used to quantify emicizumab by LC-MS/MS analysis. Validation was performed in accordance with the "Guideline on Bioanalytical Method Validation" of the European Medicines Agency (EMA). The LC-MS/MS method was cross validated against a modified and calibrated (r 2 Diagnostics) one-stage clotting assay (OSA). Conclusions: The LC-MS/MS method demonstrated linearity over a wide range of emicizumab concentrations, far exceeding the concentrations observed in people with hemophilia A. Precision and accuracy were excellent, and all other validation parameters were also within the acceptance EMA criteria. Cross validation showed that the LC-MS/MS method and the OSA-based method can be used interchangeably for drug monitoring of emicizumab without the application of a correction factor.

15.
Biomedicines ; 10(3)2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35327435

RESUMO

Neutrophils have an important role in the immune response. These cells can be subjected to an impaired function and a shift in population depending on disease states. In sepsis, this shift is recognized and flagged by automated hematology analyzers, including the presence of band neutrophils, while these cells, although present, appear not to be detected in trauma patients. To better understand this suspected error in flagging, we set out to distinguish neutrophil populations of these two patient groups and compared these with controls. Different data-driven methods were used compared to standard algorithms used by the software of the analyzers. Using K-means clustering, we extracted neutrophils from raw hematology analyzer datafiles, and compared characteristics of these clusters between the patient groups. We observed an increased neutrophil size for both sepsis and trauma patients, but trauma patients had a smaller increase. Trauma patients also had a high proportion of cells with relatively high nuclear segmentation, which is contradictory with the presence of band neutrophils. This, in combination with the smaller size increase, might explain the inability to flag band neutrophils in trauma.

16.
Biochem Med (Zagreb) ; 32(1): 010904, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35210929

RESUMO

INTRODUCTION: Leukolysis-related pseudohyperkalemia due to preanalytical procedures may lead to erroneous (or absence of) treatment based on an invalid lab test result. We aimed to obtain a leukocyte threshold above which leukolysis-related pseudohyperkalemia becomes clinical relevant. Secondly, temporal dynamics of treatment-induced leukocyte decrease were studied to allow tailored implementation of laboratory information system (LIS) decision rules based on the leukocyte threshold to avoid leukolysis-related pseudohyperkalemia. MATERIALS AND METHODS: Potassium results of AU5811 routine chemistry (Beckman Coulter, Brea, California, USA) and iStat point of care (POC) (Abbott Diagnostics, Chicago, Illinois, USA) analysers were compared, the latter method being insensitive to leukolysis caused by pre-analytical procedures. Potassium results were combined with leukocyte counts obtained using a Cell-Dyn Sapphire haematology analyser (Abbott Diagnostics, Santa Clara, California, USA), resulting in 132 unique data triplets. Regression analysis was performed to establish a leukocyte threshold. The Reference Change Value (√2 x Z x √(CVa 2 + CVi 2)) was used to calculate maximum allowable difference between routine analyser and POC potassium results (deltamax + 0.58 mmol/L). Temporal analysis on the treatment-induced leukocyte decrease was performed by plotting leukocyte counts in time for all patients above the threshold leukocyte count (N = 41). RESULTS: Established leukocyte threshold was 63 x109/L. Temporal analysis showed leukocyte counts below the threshold within 8 days of treatment for all patients. CONCLUSIONS: Based on performed analyses we were able to implement LIS decision rules to reduce pseudohyperkalemia due to preanalytical procedures. This implementation can contribute to a reduction in erroneous (or absence of) treatments in the clinic.


Assuntos
Hematologia , Hiperpotassemia , Criança , Humanos , Hiperpotassemia/diagnóstico , Hiperpotassemia/etiologia , Contagem de Leucócitos , Leucócitos , Potássio
17.
J Thromb Haemost ; 20(5): 1206-1212, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35150462

RESUMO

BACKGROUND: Pulmonary embolism (PE) occurs in one-third of critically-ill COVID-19 patients. Although prior studies identified several pathways contributing to thrombogenicity, it is unknown whether this is COVID-19-specific or also occurs in ARDS patients with another infection. OBJECTIVE: To compare pathway activity among patients having COVID-19 with PE (C19PE+), COVID-19 without PE (C19PE-), and influenza-associated ARDS (IAA) using a targeted proteomics approach. METHODS: We exploited an existing biorepository containing daily plasma samples to carefully match C19PE+ cases to C19PE- and IAA controls on mechanical ventilation duration, PEEP, FiO2, and cardiovascular-SOFA (n = 15 per group). Biomarkers representing various thrombosis pathways were measured using proximity extension- and ELISA-assays. Summed z-scores of individual biomarkers were used to represent total pathway activity. RESULTS: We observed no relevant between-group differences among 22 biomarkers associated with activation of endothelium, platelets, complement, coagulation, fibrinolysis or inflammation, except sIL-1RT2 and sST2, which were lower in C19PE- than IAA (log2-Foldchange -0.67, p = .022 and -1.78, p = .022, respectively). However, total pathway analysis indicated increased activation of endothelium (z-score 0.2 [-0.3-1.03] vs. 0.98 [-2.5--0.3], p = .027), platelets (1.0 [-1.3-3.0] vs. -3.3 [-4.1--0.6], p = .023) and coagulation (0.8 [-0.5-2.0] vs. -1.0 [-1.6-1.0], p = .023) in COVID-19 patients (C19PE+/C19PE- groups combined) compared to IAA. CONCLUSION: We observed only minor differences between matched C19PE+, C19PE-, and IAA patients, which suggests individual biomarkers mostly reflect disease severity. However, analysis of total pathway activity suggested upregulation of some distinct processes in COVID-19 could be etiologically related to increased PE-risk.


Assuntos
COVID-19 , Influenza Humana , Embolia Pulmonar , Síndrome do Desconforto Respiratório , Trombose , Biomarcadores , COVID-19/complicações , Humanos , Influenza Humana/complicações , Influenza Humana/diagnóstico , Proteômica , Embolia Pulmonar/diagnóstico , SARS-CoV-2
18.
Clin Biochem ; 104: 30-35, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35123976

RESUMO

OBJECTIVES: Capillary blood samples are generally assumed as unsuitable for coagulation testing since it is recognized that contamination with tissue factor and dilution with tissue fluid affects the coagulation assay. However, limited data is available about coagulations assays in which capillary blood sampling is compared to the standard venous blood withdrawal method. The aim of this study was to perform a method comparison between capillary and venous blood sampling for routine coagulation assays. METHODS: Both venous and capillary (finger stick) blood samples were collected from 188 healthy volunteers and patients. In citrate plasma, International Normalized Ratio (INR), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen, and D-dimer were measured according to routine protocols using the ACL-TOP 750 LAS (Werfen) coagulation analyzer. Regression analysis was performed and the mean relative difference between capillary and venous sampling was reflected to the total allowable error (TEa). RESULTS: Strong correlations and acceptable variations, using the TEa as decision limit, were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling. However, capillary sampling resulted in significant shorter APTT values when using the standard APTT-SP Liquid reagent with a mean bias of -10.4% [95% CI -12.4 to -8.4]. CONCLUSION: Based on these results, capillary blood sampling proved to be an alternative blood withdrawal method for routine coagulation assays, with the exception of APTT, if a venipuncture is unavailable or undesired.


Assuntos
Coagulação Sanguínea , Flebotomia , Testes de Coagulação Sanguínea , Fibrinogênio/análise , Humanos , Tempo de Tromboplastina Parcial
20.
J Thromb Haemost ; 19(11): 2873-2883, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34339085

RESUMO

BACKGROUND: Severe postpartum hemorrhage (SPPH) is the leading cause of maternal mortality and morbidity worldwide. Platelet anomalies frequently occur during pregnancy. However, their role in the etiology of SPPH is largely unknown. OBJECTIVE: To study the relation between platelet parameters and SPPH. METHODS: This retrospective single-center cohort included deliveries between 2009 and 2017. SPPH was defined as ≥1000 ml blood loss within 24 h after delivery. Platelet parameters were measured within 72 h before delivery. Multiple imputation was performed for missing data. Odds ratios were adjusted (aORs) for maternal age, multiple gestation, macrosomia, induction of labor, preeclampsia, and hemolysis, elevated liver enzymes, and low platelets syndrome. RESULTS: A total of 23 205 deliveries were included. Of the 2402 (10.4%) women with thrombocytopenia (<150 × 109 /L), 10.3% developed SPPH, compared with 7.6% of women with a normal platelet count (aOR: 1.34, 95% CI: 1.14-1.59). Women with a platelet count of <50 × 109 /L were most at risk (aOR of 2.24 [1.01-4.94]) compared with the reference group with normal platelet counts; the aOR was 1.22 (0.77-1.93) for the 50-99 × 109 /L platelet count group and 1.31 (1.10-1.56) for the 100-149 × 109 /L platelet count group. Plateletcrit was associated with SPPH (aOR 1.15 [1.08-1.21] per 0.05% decrease), and, although rarely present, a platelet distribution width (PDW) ≥23% (n = 22) also increased the odds of SPPH (aOR 6.05 [2.29-16.20]). CONCLUSION: Different degrees of thrombocytopenia were independently associated with the occurrence of SPPH. Despite their relation to SPPH, plateletcrit and a PDW of ≥23% have limited additional value in addition to platelet count.


Assuntos
Hemorragia Pós-Parto , Estudos de Coortes , Feminino , Humanos , Idade Materna , Contagem de Plaquetas , Hemorragia Pós-Parto/diagnóstico , Hemorragia Pós-Parto/epidemiologia , Gravidez , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...