J Magn Reson Imaging ; 39(2): 455-62, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23633229

RESUMO

PURPOSE: To evaluate a method to enable single-slice or multiple-slice cine phase contrast (cine-PC) acquisition during a single breath-hold using a highly sparsified radial acquisition ordering and temporally constrained image reconstruction with a spatially varying temporal constraint. MATERIALS AND METHODS: Simulated and in vivo cine-PC datasets of the proximal ascending aorta were obtained at different acceleration factors using a view projection acquisition order optimized for temporally constrained reconstruction (TCR). Reconstruction of the sparse cine-PC data performed with TCR was compared to reconstructions using zero-filled regridding and temporal interpolation. RESULTS: TCR resulted in more accurate velocity measurements than regridding or temporal interpolation. In one dataset, TCR of undersampled in vivo data (16 views per cardiac phase) resulted in a peak systolic velocity within 3.3% of the value measured by Doppler ultrasound while shortening the scan time to 13 seconds. High temporal-resolution undersampled TCR was also compared lower temporal-resolution, more highly sampled, regridding in three normal volunteers. CONCLUSION: TCR proved to be an effective method for reconstructing undersampled radial PC data. Although TCR utilizes a temporal constraint, temporal blurring was minimized by using appropriate constraint weights in addition to a spatially varying temporal constraint. TCR allowed for the acquisition time to be reduced to the duration of a breath-hold, while still resulting in accurate velocity measurements.


Assuntos
Aorta/patologia , Artefatos , Suspensão da Respiração , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Algoritmos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade
2.
Magn Reson Med ; 66(5): 1286-92, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21702060

RESUMO

High-resolution turbo spin echo (TSE) images have demonstrated important details of carotid artery morphology; however, it is evident that pulsatile blood and wall motion related to the cardiac cycle are still significant sources of image degradation. Although ECG gating can reduce artifacts due to cardiac-induced pulsations, gating is rarely used because it lengthens the acquisition time and can cause image degradation due to nonconstant repetition time. This work introduces a relatively simple method of converting a conventional TSE acquisition into a retrospectively ECG-correlated cineTSE sequence. The cineTSE sequence generates a full sequence of ECG-correlated images at each slice location throughout the cardiac cycle in the same scan time that is conventionally used by standard TSE sequences to produce a single image at each slice location. The cineTSE images exhibit reduced pulsatile artifacts associated with a gated sequence but without the increased scan time or associated nonconstant repetition time effects.


Assuntos
Artérias Carótidas/anatomia & histologia , Imagem Cinética por Ressonância Magnética/métodos , Artefatos , Eletrocardiografia , Humanos