Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 208-209: 106047, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31526956

RESUMO

As part of an underground gas migration study, two radioactive noble gases (37Ar and 127Xe) and two stable tracer gases (SF6 and PFDMCH) were injected into a historic nuclear explosion test chimney and allowed to migrate naturally. The purpose of this experiment was to provide a bounding case (natural transport) for the flow of radioactive noble gases following an underground nuclear explosion. To accomplish this, soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 m) to deeper levels (~160 m) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species in the case when the driving pressure from the cavity is low. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.


Assuntos
Gases Nobres/análise , Armas Nucleares , Monitoramento de Radiação , Radioatividade , Explosões , Nevada , Medidas de Segurança
2.
J Environ Radioact ; 178-179: 28-35, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28755564

RESUMO

Pacific Northwest National Laboratory reports on the detection of 39Ar at the location of an underground nuclear explosion on the Nevada Nuclear Security Site. The presence of 39Ar was not anticipated at the outset of the experimental campaign but results from this work demonstrated that it is present, along with 37Ar and 85Kr in the subsurface at the site of an underground nuclear explosion. Our analysis showed that by using state-of-the-art technology optimized for radioargon measurements, it was difficult to distinguish 39Ar from the fission product 85Kr. Proportional counters are currently used for high-sensitivity measurement of 37Ar and 39Ar. Physical and chemical separation processes are used to separate argon from air or soil gas, yielding pure argon with contaminant gases reduced to the parts-per-million level or below. However, even with purification at these levels, the beta decay signature of 85Kr can be mistaken for that of 39Ar, and the presence of either isotope increases the measurement background level for the measurement of 37Ar. Measured values for the 39Ar measured at the site ranged from 36,000 milli- Becquerel/standard-cubic-meter-of-air (mBq/SCM) for shallow bore holes to 997,000 mBq/SCM from the rubble chimney from the underground nuclear explosion.


Assuntos
Argônio/análise , Armas Nucleares , Monitoramento de Radiação , Poluentes Radioativos/análise , Nevada
3.
Appl Radiat Isot ; 126: 243-248, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28236555

RESUMO

This paper describes the generation of 39Ar, via reactor irradiation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield two calibration standards that are respectively 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory's shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50× 39Ar in P10 standard is 3.6% (k=2).

4.
Appl Radiat Isot ; 108: 92-99, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26720259

RESUMO

Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes - primarily α and ß activity in the uranium and thorium decay chains - inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportional counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as (37)Ar.

5.
Appl Radiat Isot ; 109: 430-434, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26701655

RESUMO

Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level (37)Ar standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level (37)Ar standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...