This report presents a seimic fragility analysis of equipment structures in an electric substation in Memphis, Tennessee. The eletric subtation selected for this study is substation 21, which is located near several major hospital in downtown Memphis. Substation 21 consists of several major types of equipment and structures, for example, 115/12 kV transformers, oil circuit breakers, and switch structures. The failure of equipment and structures is defined as the state at which a component (an equipment or a structure) fails to perform its function. The capacity corresponding to this damage state is then established. On the other hand, the seismic response of a component is determined by either a response spectral analysis or a static analysis. The uncertainties in seismic response and capacity are quantified to determine the probabilities of failure corresponding to various levels of ground shaking. The results are displayed as fragility curves. From the fragility analysis results, the seismic performance of equipment and structures in a substation can be revealed. For example, 115/12 kV transformers in substation 21 are very vulnerable to earthquakes even with moderate magnitude. The fragility analysis results can also provide the necessary data for evaluating the seismic performance of the entire substation and for performing a reliability analysis of the electric transmission system


Assuntos
Terremotos , Medição de Risco , Eletricidade , Serviço Hospitalar de Engenharia e Manutenção
3.
New York; U.S. National Center for Earthquake Engineering Research; Jun.1994. (149) p. ilus, Tab.(Technical Report NCEER, 94-0015).
Monografia em En | Desastres | ID: des-6135

RESUMO

This report presents an analytical method for generating fragility curves and corresponding damage probability matrix for structures subject to earthquakes. In the proposed method, seismic hazards, local soil conditions, and nonlinear building behavior are systematically considered, and all the uncertainties in seismic, site, and structural parameters are taken into account. For an illustration, the proposed method is used to generate fragility curves and damage probability matrix for Smith Hall on the main campus of the University of Memphis, which is located close to the New Madrid seismic zone. The expected damage cost is also estimated based on the 1993 replacement value of the building.(AU)