Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Endoscopy ; 55(10): 918-926, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37156511

RESUMO

BACKGROUND: Endoscopy is considered the third highest generator of waste within healthcare. This is of public importance as approximately 18 million endoscopy procedures are performed yearly in the USA and 2 million in France. However, a precise measure of the carbon footprint of gastrointestinal endoscopy (GIE) is lacking. METHODS: This retrospective study for 2021 was conducted in an ambulatory GIE center in France where 8524 procedures were performed on 6070 patients. The annual carbon footprint of GIE was calculated using "Bilan Carbone" of the French Environment and Energy Management Agency. This multi-criteria method accounts for direct and indirect greenhouse gas (GHG) emissions from energy consumption (gas and electricity), medical gases, medical and non-medical equipment, consumables, freight, travel, and waste. RESULTS: GHG emissions in 2021 were estimated to be 241.4 tonnes CO2 equivalent (CO2e) at the center, giving a carbon footprint for one GIE procedure of 28.4 kg CO2e. The main GHG emission, 45 % of total emissions, was from travel by patients and center staff to and from the center. Other emission sources, in rank order, were medical and non-medical equipment (32 %), energy consumption (12 %), consumables (7 %), waste (3 %), freight (0.4 %), and medical gases (0.005 %). CONCLUSIONS: This is the first multi-criteria analysis assessing the carbon footprint of GIE. It highlights that travel, medical equipment, and energy are major sources of impact, with waste being a minor contributor. This study provides an opportunity to raise awareness among gastroenterologists of the carbon footprint of GIE procedures.


Assuntos
Pegada de Carbono , Gases de Efeito Estufa , Humanos , Estudos Retrospectivos , Gases de Efeito Estufa/análise , Endoscopia Gastrointestinal , França
3.
Endosc Int Open ; 10(5): E679-E685, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35571467

RESUMO

Background and study aims Image-guided minimally invasive techniques have transformed the management of malignant and benign bile duct obstructions. These evolving techniques are being widely adopted and applied and hands-on training using high quality models is required to improve the proficiency of practitioners. This experimental study aimed to validate an in vivo porcine model created to simulate bile duct dilation for interventional endoscopic ultrasound (EUS) hands-on training curriculums. Materials and methods Thirty-six porcine models were involved and the procedures were performed in an experimental hybrid operating room under general anesthesia. Animals underwent endoscopic duodenal papilla clipping with several hemostatic metallic clips. After a survival period of 24 to 48 hours, the models with effective intrahepatic and extrahepatic bile duct dilatation were included in the hands-on training. Trainees and faculty were given structured evaluations of the model realism and usefulness. Results Extrahepatic bile duct and gallbladder dilation was achieved in all 36 of the models, and in 11 of the 36 models, a treatable intrahepatic duct dilatation was achieved. During the hands-on training, EUS-guided biliary drainage, EUS-guided transgastric gallbladder drainage, and EUS through-the-needle microbiopsy forceps procedures were feasible. Overall, 75 % of the experts and trainees evaluated the training as excellent. Conclusions We present a minimally invasive, reliable and time- effective model of extrahepatic dilation suitable for interventions. The model was less effective for intrahepatic ducts, which should be considered if intrahepatic biliary dilation is required for training.

4.
Endosc Ultrasound ; 11(2): 112-121, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35488623

RESUMO

Background and Objectives: EUS has evolved into a therapeutic modality for gastrointestinal disorders. Simulators, ex vivo models, and phantoms are the current teaching methods for therapeutic EUS (TEUS). We create and evaluate a high-fidelity simulated live animal model (HiFi SAM) for teaching endoscopists TEUS. Materials and Methods: Designing a curriculum that uses HiFi SAM and enables trainees to perform realistic procedures with expert mentors. Results: Twenty-seven trainees participated in a 3-day program with 6 h of theoretical and 14 h of hands using life HiFi SAM. Eighteen experts participated. Twenty-two (20-25) TEUS were defined for each HiFi SAM, and 616 were performed in all. Of 616/264 (43%) were evaluated with a mean of 88 per course (ranging between 80 and 95). Ninety-one percent (240/264) of the procedures were completed successfully. In 24, success was not achieved due to technical and/or model problems. Student rating of HiFi SAM was: 71% excellent rating (scale 8-10) and 95% excellent/good. The HiFi SAM procedure evaluation was (scale 1-5): fine-needle biopsy: 4.79, radiofrequency: 4.76, common bile duct and gallbladder drainage: 4.75, cystic drainages: 4.72, neurolysis: 4.55, microbiopsy: 4.50, and hepatogastric drainage: 4.04, with an overall satisfaction rate of 4.56 (91%). A short survey showed: 83% would recommend absolutely (17% most likely), 33% think that ITEC training was sufficient for their practice, and 66% would like additional training, especially more practice in specific techniques rather than more clinical case discussion. Regarding impact on their practice, 66% of the trainees started a new procedure and/or noted improvement in previous ones. Conclusion: HiFi SAM is a complex model; however, experts and trainees are satisfied with the training this new curriculum provided.

5.
Ann Surg Oncol ; 28(2): 1069-1078, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32514806

RESUMO

BACKGROUND: Global health systems are shifting toward value-based health care to improve patient outcomes in the face of rising health care costs. The challenge is to identify standardized outcome measurements that allow optimal quality-of-care monitoring and comparison to optimize medical practices and patient pathways. A common outcomes definition is required, including medical results (Clinical Reported Outcomes Measurements [CROMs]) and quality-of-life components that matter most to patients (Patient-Reported Outcomes Measurements [PROMs]), which are particularly important for severe pathologies with short life expectancy such as pancreatic cancer. This study aimed to create standardized metrics that could be used for outcomes analysis of pancreatic cancer care. METHODS: A multidisciplinary working group (WG) was assembled. A systematic review was performed to collect the most used outcomes in clinical studies of pancreatic cancers. The study reviewed 570 studies published in the last 10 years. From these studies, 3370 outcomes, including CROMs, and PROMs, were listed and prioritized. The WG reached a consensus on key outcomes, proposed groupings for CROMs and PROMs, identified existing questionnaires that could be used for PROMs collection, and set the timeline for data collection. To refine and validate the final outcomes set, an international external committee completed a Delphi process (two rounds for both CROMS and PROMs). RESULTS: After the systematic literature review, the WG selected 102 outcomes (92 CROMs and 10 PROMs) for submission to the international Delphi vote committee. The committee retrained 89 outcomes (78 CROMs and 11 PROMs). For the PROMs, the WG and the international external committee chose a validated questionnaire, the Functional Assessment of Cancer Therapy-Hepatobiliary, which covers all of the 11 selected PROMs. CONCLUSIONS: A standardized set of outcome measures that need to be validated through international health outcome comparisons and quality-of-care assessments was built. Pilot projects are underway to test and optimize the approach in real-life conditions.


Assuntos
Avaliação de Resultados em Cuidados de Saúde , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/terapia , Assistência Centrada no Paciente , Qualidade de Vida , Padrões de Referência , Inquéritos e Questionários , Neoplasias Pancreáticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...