1.
Opt Express
; 29(4): 5295-5303, 2021 Feb 15.
Artigo
em Inglês
| MEDLINE
| ID: mdl-33726068
RESUMO
We report on the design and automation of a mid-infrared, continuous wave, singly-resonant optical parametric oscillator. Hands-free controls and the implementation of a tuning algorithm allowed for hundreds of nanometers of continuous, effective-mode-hop-free tuning over the range of 2190-4000 nm. To demonstrate the applicability of this light source and algorithm to mid-IR spectroscopy, we performed a sample spectroscopy measurement in a C2H2 gas cell and compared the experimentally-measured absorption spectrum to HITRAN 2016 simulations. We found excellent agreement with simulation in both peak heights and peak centers; we also report a reduced uncertainty in peak centers compared to simulation.