Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Int J Surg Case Rep ; 83: 105973, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34004563

RESUMO

INTRODUCTION AND IMPORTANCE: Near infrared fluorescence imaging with indocyanine green (ICG) can facilitate the intraoperative tumour localization and therefore a complete resection. Cholangiocarcinoma is an aggressive tumour and complete resection improves the outcome. Therefore, it is necessary to localize the tumour exactly but the translation of the preoperative imaging into the intraoperative setting can be difficult based only on sonography, computed tomography or magnetic resonance imaging. CASE PRESENTATION/CLINICAL FINDINGS AND INVESTIGATIONS/INTERVENTIONS AND OUTCOME: In this case a hepatic lesion suspicious for cholangiocarcinoma was discovered accidentally. Further diagnostics were unable to prove the diagnosis, therefore right hepatectomy was recommended and performed. Preoperatively ICG was administered and near infrared imaging was used intraoperatively clearly localizing the tumour, thus facilitating the resection. The intra- and postoperative course was uneventful. RELEVANCE AND IMPACT: This case report supports the very promising intraoperative use of fluorescence imaging for the localization of superficial hepatic tumours. Timing and correct administration of ICG is important.

2.
J Hepatol ; 74(2): 419-427, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33065168

RESUMO

BACKGROUND & AIMS: CT may miss up to 30% of cases of colorectal liver metastases (CRLMs). We assessed the impact of contrast-enhanced ultrasound (CEUS) on the detection of CRLMs and on changes to the therapeutic strategy; additionally, we assessed the accuracy of CEUS in differentiating unclear focal liver lesions (FLLs) compared to staging-CT. METHODS: We prospectively analyzed all patients with newly diagnosed and histologically confirmed colorectal cancer (CRC) at our tertiary gastroenterological center between December 2015 and May 2019. CEUS was performed in a total of 296 patients without CRLMs after staging-CT using the contrast agent (SonoVue®). Standard of reference was obtained by MRI or histology to diagnose CRLMs missed by CT. Benign FLLs were confirmed by MRI or follow-up CT (mean follow-up interval: 18 months). RESULTS: Eight additional CRLMs were detected by CEUS (overall 2.7%; sensitivity 88.9%, specificity 99.0%, positive predictive value 100%, negative predictive value 99.6%). All patients with CRLMs detected only by CEUS were in tumor stage T3/T4 (4.0% additionally detected CRLMs). The number needed to screen to detect 1 additional CRLM by CEUS was 37 in all patients and 24.5 in T3/T4-patients. When results were reviewed by a board-certified radiologist and oncologist, the therapeutic strategy changed in 6 of these 8 patients. Among the 62 patients (20.9%) with unclear FLLs after staging-CT, CEUS determined the dignity (malignant vs. benign) of 98.4% of the FLLs. CONCLUSION: Overall, CEUS detected 2.7% additional CRLMs (including 4.0% in tumor stage T3/T4) with a significant impact on the oncological therapeutic strategy for 75% of these patients. Patients with tumor stage T3/T4 would particularly benefit from CEUS. We propose CEUS as the first imaging modality for CT-detected lesions of unknown dignity. LAY SUMMARY: In patients with newly diagnosed colorectal cancer, contrast-enhanced ultrasound (CEUS) detected additional liver metastases after computed tomography (CT). In the majority of these patients, the oncological therapy was changed after obtaining the CEUS results. After staging-CT, 21% of hepatic lesions remained unclear. In these cases, CEUS was accurate to either reveal or exclude liver metastasis in nearly all patients and could reduce costs (e.g., number of MRI scans).


Assuntos
Neoplasias Colorretais/patologia , Aumento da Imagem/métodos , Neoplasias Hepáticas , Metástase Neoplásica/diagnóstico por imagem , Fosfolipídeos/farmacologia , Hexafluoreto de Enxofre/farmacologia , Ultrassonografia/métodos , Idoso , Neoplasias Colorretais/terapia , Meios de Contraste/farmacologia , Feminino , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Masculino , Oncologia/métodos , Oncologia/normas , Estadiamento de Neoplasias , Melhoria de Qualidade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
4.
AJR Am J Roentgenol ; 207(2): 310-20, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27253268

RESUMO

OBJECTIVE: The purpose of this study was to prospectively investigate the clinical feasibility of adopting splenic enhancement for timing and triggering the acquisition of late hepatic arterial phase images during multiphasic liver MDCT for assessment of hypervascular tumors. SUBJECTS AND METHODS: Forty-eight patients (33 men, 15 women; median age, 59 years; chronic liver disease, 23 patients; portal venous hypertension, 17 patients) with a total of 81 hypervascular liver tumors underwent liver MDCT by random assignment to one of two scanning protocols. Scanning delay for the late hepatic arterial phase was determined by assessment of time-to-peak splenic enhancement (splenic-triggering protocol) or aortic enhancement (aortic-triggering protocol). Acquisition timing, vascular attenuation, liver attenuation and homogeneity, signal-to-noise ratio, tumor-to-liver contrast, and tumor-to-liver contrast-to-noise ratio were compared. Two blinded independent observers used Likert scales to score timing adequacy (3-point scale), diagnostic confidence (5-point scale), and per lesion conspicuity (4-point scale) for hypervascular tumor detection. RESULTS: The splenic- and aortic-triggering protocols had significant differences in mean late hepatic arterial phase imaging timing (splenic, 36 ± 6 seconds; aortic, 32 ± 3 seconds; p = 0.010). Images obtained with the splenic-triggering protocol had significantly better observer-based judgment of adequacy (splenic, 2.04; aortic, 1.58; p = 0.002). Mean attenuation and signal-to-noise ratios from liver and portal vein were significantly higher with the splenic- than with the aortic-triggering protocol (p < 0.0001). The splenic-triggering protocol was associated with significant improvement in homogeneity of liver attenuation (p < 0.0001). Although the splenic-triggering protocol was associated with significantly higher lesion conspicuity than was the aortic-triggering protocol (p = 0.022), there was no significant difference in tumor detection rate. CONCLUSION: Our results provide a clinical foundation for and proof of principle that the adoption of splenic enhancement renders an optimal temporal window for late hepatic arterial phase imaging during MDCT of the liver for assessment of hypervascular tumors.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Baço/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
5.
Radiology ; 280(3): 960-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26937711

RESUMO

Purpose To prospectively develop individualized low-volume contrast media (CM) protocols adapted to tube voltage in patients undergoing computed tomographic (CT) angiography of the aorta. Materials and Methods The study was approved by the institutional review board and local ethics committee. All patients provided written informed consent. CT angiography was performed by using automated attenuation-based tube voltage selection (ATVS) (range, 70-150 kVp; 10-kVp increments). Iodine attenuation curves from an ex vivo experiment in a phantom were used to design CM protocols for CT angiography of the thoracoabdominal aorta in 129 consecutive patients (hereafter, cohort A). Further modified CM protocols based on results in cohort A were designed with the aim of homogeneous vascular attenuation of 300-350 HU across tube voltages and were applied to another 61 consecutive patients (cohort B). Three independent blinded radiologists assessed subjective image quality, and one reader determined objective image quality. The Kruskal-Wallis test was performed to test for differences in subjective image quality, and linear regression was performed to test for differences in objective image quality between the automatically selected tube voltages. Results Experiments revealed tube voltage-dependent iodine attenuation curves, which were used to determine the CM protocols in cohort A; these ranged from 68 mL at 110 kVp to 45 mL at 80 kVp. In both cohorts, ATVS selected 80 kVp in 62 patients, 90 kVp in 84, 100 kVp in 33, and 110 kVp in 11. In cohort A, image quality that was satisfactory or better was attained in 126 (98%) of 129 patients who had no significant differences in subjective image quality between tube voltages (P = .106) but who did have significant differences in attenuation and contrast-to-noise ratio (CNR) (P < .001 for both). In cohort B, the further-modified CM protocol (from 33 mL at 80 kVp to 68 mL at 110 kVp) yielded image quality that was satisfactory or better in all 61 (100%) patients, without significant differences in subjective image quality (P = .178), and without significant differences between tube voltage and attenuation (P = .108), noise (P = .250), or CNR (P = .698). Conclusion Individualized low-volume CM protocols based on automatically selected tube voltages are feasible and yield diagnostic image quality for CT angiography of the aorta. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador
6.
Invest Radiol ; 51(4): 241-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26646307

RESUMO

OBJECTIVE: The aim of this study was to evaluate the potential of contrast media (CM) reduction in computed tomography angiography (CTA) of coronary artery bypass grafts (CABGs) when adapting CM volume to automatically selected tube voltages. MATERIAL AND METHODS: Sixty consecutive patients (mean age, 71 ± 14.5 years) with a total of 176 CABGs (692 bypass segments) underwent contrast-enhanced prospectively electrocardiography-gated high-pitch CTA with automated, attenuation-based tube voltage selection (100 ref. peak kilovoltage [kVp], 200 ref. mAs, tube voltages from 70-150 kVp in 10-kVp steps) using a third-generation 192-slice dual-source computed tomography scanner. Volume and flow of CM (370 mg/mL iodine) was adapted according to the tube voltages using iodine attenuation-curves derived from a foregoing phantom study. In patients, CM volumes ranged from 80 mL (flow rate, 7 mL/s) at 120 kVp to 48 mL (flow rate, 4.2 mL/s) at 80 kVp. Two independent, blinded readers evaluated subjective image quality of the proximal anastomosis, bypass graft, distal anastomosis, and postanastomotic native coronary artery using a 3-point Likert scale. Objective image quality (attenuation of graft and noise) was determined and contrast-to-noise ratio (CNR) was calculated. Volume computed tomography dose index and dose-length product of each CTA examination were noted. Cohen κ was used to define interreader agreement of subjective image quality. Regression analysis was used to determine relationships between tube voltage and vascular attenuation, image noise, and CNR. RESULTS: Using attenuation-based tube voltage selection, 5 patients (8%) were scanned at 80 kVp, 22 (37%) at 90 kVp, 11 (18%) at 100 kVp, 10 (17%) at 110 kVp, and 12 (20%) at 120 kVp. Agreement in subjective image quality between readers was good (κ = 0.678). Diagnostic image quality was achieved in 679 of 692 (98%) bypass segments in 169 of 176 bypass grafts (96%). Thirteen of 692 bypass segments (2%) in 7 of 176 bypass grafts (4%) were rated as nondiagnostic because of severe artifacts caused by motion or beam hardening (2 proximal anastomoses of sequential bypasses, 3 graft bodies, 5 distal anastomoses, and 3 postanastomotic coronary artery segments). Regression analysis revealed no significant relationship between the automatically selected tube voltages and objective image quality parameters (bypass graft attenuation: P = 0.315; noise: P = 0.433; and CNR: P = 0.168), indicating homogenous attenuation, noise, and CNR across tube voltage levels. Mean volume computed tomography dose index was 4.0 ± 0.9 mGy, and mean dose length product was 135.0 ± 29.6 mGy*cm. CONCLUSION: Adapting CM protocols to automatically selected tube voltage levels allows for low-volume CM CTA examinations of CABG grafts with diagnostic image quality.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Ponte de Artéria Coronária , Iohexol/análogos & derivados , Idoso , Algoritmos , Feminino , Humanos , Iohexol/administração & dosagem , Masculino
7.
Eur Radiol ; 26(2): 459-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26037718

RESUMO

PURPOSE: To evaluate the potential of advanced modeled iterative reconstruction (ADMIRE) for optimizing radiation dose of high-pitch coronary CT angiography (CCTA). METHODS: High-pitch 192-slice dual-source CCTA was performed in 25 patients (group 1) according to standard settings (ref. 100 kVp, ref. 270 mAs/rot). Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). In another 25 patients (group 2), high-pitch CCTA protocol parameters were adapted according to results from group 1 (ref. 160 mAs/rot), and images were reconstructed with ADMIRE level 4. In ten patients of group 1, vessel sharpness using full width at half maximum (FWHM) analysis was determined. Image quality was assessed by two independent, blinded readers. RESULTS: Interobserver agreements for attenuation and noise were excellent (r = 0.88/0.85, p < 0.01). In group 1, ADMIRE level 4 images were most often selected (84%, 21/25) as preferred data set; at this level noise reduction was 40% compared to FBP. Vessel borders showed increasing sharpness (FWHM) at increasing ADMIRE levels (p < 0.05). Image quality in group 2 was similar to that of group 1 at ADMIRE levels 2-3. Radiation dose in group 2 (0.3 ± 0.1 mSv) was significantly lower than in group 1 (0.5 ± 0.3 mSv; p < 0.05). CONCLUSIONS: In a selected population, ADMIRE can be used for optimizing high-pitch CCTA to an effective dose of 0.3 mSv. KEY POINTS: • Advanced modeled IR (ADMIRE) reduces image noise up to 50% as compared to FBP. • Coronary artery vessel borders show an increasing sharpness at higher ADMIRE levels. • High-pitch CCTA with ADMIRE is possible at a radiation dose of 0.3 mSv.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
8.
Invest Radiol ; 50(10): 695-702, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26002623

RESUMO

OBJECTIVE: To determine the value of advanced virtual monoenergetic images (mono+) from dual-energy computed tomography (CT) of hyperattenuating and hypoattenuating liver lesions in various phantom sizes and patients in comparison with standard monoenergetic images (mono). MATERIALS AND METHODS: Anthropomorphic phantoms simulating 4 patient sizes (S, 300 × 200 mm; M, 350 × 250 mm; L, 400 × 300 mm; and XL, 600 × 450 mm) with a liver insert containing both hyperattenuating and hypoattenuating iodine-containing lesions were imaged with dose-equivalent dual-energy (100/150 Sn kilovolt [peak] [kV{p}]) and single-energy (120 kV[p]) protocols on a 192-slice dual-source CT system. In addition, 4 patients with 3 hypoattenuating and 3 hyperattenuating hepatocellular carcinoma were included and underwent dual-energy CT imaging with the same scanner at similar kV(p) settings (100/150 Sn kV[p]). Images were reconstructed with standard mono and with the mono+ algorithm at 10-kiloelectron volt (keV) intervals from 40 to 190 keV. Attenuation of the liver and lesions were measured, and contrast-to-noise ratios (CNRs) were calculated. Lesion conspicuity was rated by 2 blinded independent readers in all mono and mono+ data sets from 40 to 190 keV using a 5-point Likert scale (1, lowest conspicuity; and 5, highest conspicuity). RESULTS: Attenuation in the liver and in both hyperattenuating and hypoattenuating lesions did not differ between mono and mono+ (P = 0.41-0.49). Noise on mono+ was significantly lower than on mono for all phantom sizes (P < 0.05) and was increasing with phantom size. Hyperattenuating lesion CNR was highest for mono+ images at 40 keV in the S phantom (6.73), with significantly higher CNR for mono+ than for mono and for single energy (120 kV[p]) in all phantom sizes (all P < 0.001) except for the XL phantom. Hypoattenuating lesion CNR was highest for high-keV mono+ being significantly higher than on mono and on single-energy (120 kV[p]) images (all P < 0.001), except for the XL phantom with significantly higher CNR for mono (1.3) compared with mono+ (0.47) and 120 kV(p) (1.26). In patients, CNR curves of hyperattenuating hepatocellular carcinoma were in accordance with the phantom data, whereas hypoattenuating lesions demonstrate varying curves, some being in accordance with findings in phantoms. Interreader agreement for lesion conspicuity was very good (intraclass correlation, 0.95), with higher conspicuity scores for mono+ than for mono and single energy (120 kV[p]) at all phantom sizes (all P < 0.05) and within patients. CONCLUSION: Our ex vivo and patient data demonstrate added value for imaging of both hyperattenuating and hypoattenuating liver lesions with advanced virtual monoenergetic dual-energy CT by decreased noise, increased CNR, and higher lesion conspicuity, although with limitations in XL body sizes.


Assuntos
Tamanho Corporal , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
9.
Eur Radiol ; 25(8): 2346-53, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25693663

RESUMO

OBJECTIVE: To assess radiation dose and image quality in body CT-angiography (CTA) with automated attenuation-based tube voltage selection (ATVS) on a 192-slice dual-source CT (DSCT). METHODS: Forty patients (69.5 ± 9.6 years) who had undergone body CTA with ATVS (ref.kVp 100, ref.mAs 90) using a 2x192-slice CT in single-source mode were retrospectively included. All patients had undergone prior CTA with a 2x128-slice CT and ATVS with identical imaging and contrast media protocols, serving for comparison. Images were reconstructed with iterative reconstruction at similar strength levels. Radiation dose was determined. Image quality was assessed semi-quantitatively (1:excellent, 5:non-diagnostic), aortic attenuation, noise and CNR were determined. RESULTS: As compared to 128-slice DSCT, 192-slice DSCT selected tube voltages were lower in 30 patients (75 %), higher in 3 (7.5 %), and similar in 7 patients (17.5 %). CTDIvol was lower with 192-slice DSCT (4.7 ± 1.9 mGy vs. 5.8 ± 2.1 mGy; p < 0.001). Subjective image quality, mean aortic attenuation (342 ± 67HU vs. 268 ± 67HU) and CNR (9.8 ± 2.5 vs. 8.2 ± 2.9) were higher with 192-slice DSCT (all p < 0.01), all datasets being diagnostic. CONCLUSION: Our study suggests that ATVS of 192-slice DSCT for body CTA is associated with an improved image quality and further radiation dose reduction of 19 % compared to 128-slice DSCT. KEY POINTS: • 192-slice DSCT allows imaging from 70 kVp to 150 kVp at 10 kVp increments. • 192-slice DSCT allows for radiation-dose reduction in body-CTA with ATVS. • Subjective and objective image quality increase compared to 128-slice DSCT.


Assuntos
Angiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Eur Radiol ; 25(3): 679-86, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25278247

RESUMO

PURPOSE: To assess the impact of patient habitus, acquisition parameters, detector efficiencies, and reconstruction techniques on the accuracy of iodine quantification using dual-source dual-energy CT (DECT). MATERIALS AND METHODS: Two phantoms simulating small and large patients contained 20 iodine solutions mimicking vascular and parenchymal enhancement from saline isodensity to 400 HU and 30 iodine solutions simulating enhancement of the urinary collecting system from 400 to 2,000 HU. DECT acquisition (80/140 kVp and 100/140 kVp) was performed using two DECT systems equipped with standard and integrated electronics detector technologies. DECT raw datasets were reconstructed using filtered backprojection (FBP), and iterative reconstruction (SAFIRE I/V). RESULTS: Accuracy for iodine quantification was significantly higher for the small compared to the large phantoms (9.2 % ± 7.5 vs. 24.3 % ± 26.1, P = 0.0001), the integrated compared to the conventional detectors (14.8 % ± 20.6 vs. 18.8 % ± 20.4, respectively; P = 0.006), and SAFIRE V compared to SAFIRE I and FBP reconstructions (15.2 % ± 18.1 vs. 16.1 % ± 17.6 and 18.9 % ± 20.4, respectively; P ≤ 0.003). A significant synergism was observed when the most effective detector and reconstruction techniques were combined with habitus-adapted dual-energy pairs. CONCLUSION: In a second-generation dual-source DECT system, the accuracy of iodine quantification can be substantially improved by an optimal choice and combination of acquisition parameters, detector, and reconstruction techniques.


Assuntos
Tamanho Corporal , Iodo , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Análise de Variância , Humanos , Processamento de Imagem Assistida por Computador/métodos , Sensibilidade e Especificidade
11.
Int J Cardiovasc Imaging ; 30(6): 1173-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24816910

RESUMO

To determine the average heart rate (HR) and heart rate variability (HRV) required for diagnostic imaging of the coronary arteries in patients undergoing high-pitch CT-angiography (CTA) with third-generation dual-source CT. Fifty consecutive patients underwent CTA of the thoracic (n = 8) and thoracoabdominal (n = 42) aorta with third-generation dual-source 192-slice CT with prospective electrocardiography (ECG)-gating at a pitch of 3.2. No ß-blockers were administered. Motion artifacts of coronary arteries were graded on a 4-point scale. Average HR and HRV were noted. The average HR was 66 ± 11 beats per minute (bpm) (range 45-96 bpm); the HRV was 7.3 ± 4.4 bpm (range 3-20 bpm). Interobserver agreement on grade of image quality for the 642 coronary segments evaluated by both observers was good (κ = 0.71). Diagnostic image quality was found for 608 of the 642 segments (95%) in 43 of 50 patients (86%). In 14% of the patients, image quality was nondiagnostic for at least one segment. HR (p = 0.001) was significantly higher in patients with at least one non-diagnostic segment compared to those without. There was no significant difference (p > 0.05) in HRV between patients with nondiagnostic segments and those with diagnostic images of all segments. All patients with a HR < 70 bpm had diagnostic image quality in all coronary segments. The effective radiation dose and scan time for the heart were 0.4 ± 0.1 mSv and 0.17 ± 0.02 s, respectively. Third-generation dual-source 192-slice CT allows for coronary angiography in the prospectively ECG-gated high-pitch mode with diagnostic image quality at HR up to 70 bpm. HRV is not significantly related to image quality of coronary CTA.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Frequência Cardíaca , Tomografia Computadorizada Multidetectores , Idoso , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Eur Radiol ; 24(3): 657-67, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24154792

RESUMO

OBJECTIVES: To determine the value of combined automated attenuation-based tube-potential selection and iterative reconstructions (IRs) for optimising computed tomography (CT) imaging of hypodense liver lesions. METHODS: A liver phantom containing hypodense lesions was imaged by CT with and without automated attenuation-based tube-potential selection (80, 100 and 120 kVp). Acquisitions were reconstructed with filtered back projection (FBP) and sinogram-affirmed IR. Image noise and contrast-to-noise ratio (CNR) were measured. Two readers marked lesion localisation and rated confidence, sharpness, noise and image quality on a five-point scale (1 = worst, 5 = best). RESULTS: Image noise was lower (31-52%) and CNR higher (43-102%) on IR than on FBP images at all tube voltages. On 100-kVp and 80-kVp IR images, confidence and sharpness were higher than on 120-kVp FBP images. Scores for image quality score and noise as well as sensitivity for 100-kVp IR were similar or higher than for 120-kVp FBP and lower for 80-kVp IR. Radiation dose was reduced by 26% at 100 kVp and 56% at 80 kVp. CONCLUSIONS: Compared with 120-kVp FBP images, the combination of automated attenuation-based tube-potential selection at 100 kVp and IR provides higher image quality and improved sensitivity for detecting hypodense liver lesions in vitro at a dose reduced by 26%. KEY POINTS: • Combining automated tube voltage selection/iterative CT reconstruction improves image quality. • Attenuation values remain stable on IR compared with FBP images. • Lesion detection was highest on 100-kVp IR images.


Assuntos
Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Testes de Função Hepática , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas
13.
BMC Med Imaging ; 13: 10, 2013 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-23506523

RESUMO

BACKGROUND: To evaluate the contrast agent performance of Gd-EOB-DTPA and Gd-BOPTA for detection and assessment of extrahepatic findings, semi-quantitatively and qualitatively. METHODS: 13 patients with 19 extrahepatic lesions underwent liver MRI with Gd-EOB-DTPA and Gd-BOPTA. Quantitative and relative SNR measurements were performed in each dataset in the arterial and portalvenous phase within the extrahepatic lesion, aorta, inferior vena cava, portal vein, spleen, pancreas and renal cortex. Further, relative CNR measurements were performed. Three readers assessed contrast quality using a five-point scale and choosing the preferred image dataset. Statistical analysis consisted of a Student's t-test with p < 0.05 deemed significant, a weighted kappa statistic for assessment of interobserver variability and an ROC analysis. RESULTS: Mean SNR after injection of Gd-BOPTA was significantly higher compared with Gd-EOB-DTPA for all measurements (p < 0.05). Mean relative SNR was also higher for Gd-BOPTA, but without being statistically significant. There was no significant difference in relative CNR. Interobserver agreement for selection of image preference was moderate (mean weighted kappa 0.485). The area under the curve for the ROC-analysis regarding contrast agent performance was 0.464. CONCLUSION: Even though mean SNR is significantly higher after injection of Gd-BOPTA compared with Gd-EOB-DTPA, there is no significant difference in relative CNR with extrahepatic lesions being assessed equally well. Visual impression may differ after injection of Gd-EOB-DTPA, but does not influence image interpretation. Extrahepatic findings can be assessed similarly to MRI after injection of Gd-BOPTA.


Assuntos
Neoplasias Abdominais/patologia , Gadolínio DTPA , Hepatócitos/patologia , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Abdome/patologia , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Med Phys ; 39(7): 4115-22, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22830744

RESUMO

PURPOSE: To investigate a measurement method for evaluating the resolution properties of CT imaging systems across reconstruction algorithms, dose, and contrast. METHODS: An algorithm was developed to extract the task-based modulation transfer function (MTF) from disk images generated from the rod inserts in the ACR phantom (model 464 Gammex, WI). These inserts are conventionally employed for HU accuracy assessment. The edge of the disk objects was analyzed to determine the edge-spread function, which was differentiated to yield the line-spread function and Fourier-transformed to generate the object-specific MTF for task-based assessment, denoted MTF(Task). The proposed MTF measurement method was validated against the conventional wire technique and further applied to measure the MTF of CT images reconstructed with an adaptive statistical iterative algorithm (ASIR) and a model-based iterative (MBIR) algorithm. Results were further compared to the standard filtered back projection (FBP) algorithm. Measurements were performed and compared across different doses and contrast levels to ascertain the MTF(Task) dependencies on those factors. RESULTS: For the FBP reconstructed images, the MTF(Task) measured with the inserts were the same as the MTF measured from the wire-based method. For the ASIR and MBIR data, the MTF(Task) using the high contrast insert was similar to the wire-based MTF and equal or superior to that of FBP. However, results for the MTF(Task) measured using the low-contrast inserts, the MTF(Task) for ASIR and MBIR data was lower than for the FBP, which was constant throughout all measurements. Similarly, as a function of mA, the MTF(Task) for ASIR and MBIR varied as a function of noise--with MTF(Task) being proportional to mA. Overall greater variability of MTF(Task) across dose and contrast was observed for MBIR than for ASIR. CONCLUSIONS: This approach provides a method for assessing the task-based MTF of a CT system using conventional and iterative reconstructions. Results demonstrated that the object-specific MTF can vary as a function of dose and contrast. The analysis highlighted the paradigm shift for iterative reconstructions when compared to FBP, where iterative reconstructions generally offer superior noise performance but with varying resolution as a function of dose and contrast. The MTF(Task) generated by this method is expected to provide a more comprehensive assessment of image resolution across different reconstruction algorithms and imaging tasks.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
15.
Acad Radiol ; 19(9): 1149-57, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22743115

RESUMO

RATIONALE AND OBJECTIVES: To assess whether dual-energy computed tomography (DECT) multidetector computed tomography (MDCT) angiography improves vascular contrast beyond MDCT angiography and digital subtraction angiography (DSA) while preserving the ability to precisely characterize stenoses, using DSA as reference standard. MATERIALS AND METHODS: This prospective, Health Insurance Portability and Accountability Act-compliant, institutional review board-approved study was performed on 25 patients referred for lower extremity DECT angiography and subsequent DSA. Spectral data were postprocessed to create single-energy 120 kVp (MDCT series) and iodine-only (DECT series) datasets. The arterial tree was subdivided into 11 anatomical levels. Contrast-to-noise ratios (CNR) and corresponding coefficient -of variation (CV) of patent vessel segments were evaluated for DECT, MDCT, and DSA using analysis of variance comparisons. Degree of stenoses was determined for DECT, MDCT, and DSA and correlated with t-test, bivariate Pearson comparisons, and Bland-Altman plots. RESULTS: Patent vasculature comprised 230 vessel segments. From infrarenal aorta to distal femoral arteries, DECT showed higher CNR compared to DSA and MDCT (P < .05); distal to the popliteal arteries, DSA achieved higher CNR (P < .05). Analyses of contrast homogeneity showed minimal CV above the knee for MDCT (≤9%) and for DSA below the knee (≤7%). Stenotic vasculature comprised 33 segments. Significant correlations of stenosis severity were found comparing DECT and MDCT with DSA as reference standard showing a 0.04-fold mean underestimation of stenoses on MDCT and no detectable mean variation on DECT compared with DSA. CONCLUSION: DECT angiography improved contrast in vascular abdominopelvic and thigh distributions beyond MDCT angiography and DSA while preserving the ability to precisely assess severity of stenoses, using DSA as an accepted reference standard.


Assuntos
Angiografia Digital , Arteriopatias Oclusivas/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Doenças Vasculares Periféricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Grau de Desobstrução Vascular
16.
Invest Radiol ; 47(8): 468-74, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22717881

RESUMO

OBJECTIVE: The aim of this study was to compare the image quality of abdominal computed tomography scans in an anthropomorphic phantom acquired at different radiation dose levels where each raw data set is reconstructed with both a standard convolution filtered back projection (FBP) and a full model-based iterative reconstruction (MBIR) algorithm. MATERIALS AND METHODS: An anthropomorphic phantom in 3 sizes was used with a custom-built liver insert simulating late hepatic arterial enhancement and containing hypervascular liver lesions of various sizes. Imaging was performed on a 64-section multidetector-row computed tomography scanner (Discovery CT750 HD; GE Healthcare, Waukesha, WI) at 3 different tube voltages for each patient size and 5 incrementally decreasing tube current-time products for each tube voltage. Quantitative analysis consisted of contrast-to-noise ratio calculations and image noise assessment. Qualitative image analysis was performed by 3 independent radiologists rating subjective image quality and lesion conspicuity. RESULTS: Contrast-to-noise ratio was significantly higher and mean image noise was significantly lower on MBIR images than on FBP images in all patient sizes, at all tube voltage settings, and all radiation dose levels (P < 0.05). Overall image quality and lesion conspicuity were rated higher for MBIR images compared with FBP images at all radiation dose levels. Image quality and lesion conspicuity on 25% to 50% dose MBIR images were rated equal to full-dose FBP images. CONCLUSION: This phantom study suggests that depending on patient size, clinically acceptable image quality of the liver in the late hepatic arterial phase can be achieved with MBIR at approximately 50% lower radiation dose compared with FBP.


Assuntos
Diagnóstico por Computador/instrumentação , Artéria Hepática , Processamento de Imagem Assistida por Computador/instrumentação , Radiografia Abdominal/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Simulação por Computador , Diagnóstico por Computador/métodos , Relação Dose-Resposta à Radiação , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos
17.
Eur J Nucl Med Mol Imaging ; 39(6): 936-43, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22415598

RESUMO

PURPOSE: To investigate the clinical value of (18)F-fluorocholine PET/CT (CH-PET/CT) in treatment decisions in patients with recurrent prostate cancer (rPCA). METHODS: The study was a retrospective evaluation of 156 patients with rPCA and CH-PET/CT for restaging. Questionnaires for each examination were sent to the referring physicians 14-64 months after examination. Questions included information regarding initial extent of disease, curative first-line treatment, and the treatment plan before and after CH-PET/CT. Additionally, PSA values at diagnosis, after initial treatment, before CH-PET/CT and at the end of follow-up were also obtained from the questionnaires. RESULTS: Mean follow-up was 42 months. The mean Gleason score was 6.9 at initial diagnosis. Initial treatment was: radical prostatectomy in 110 patients, radiotherapy in 39, and combined prostatectomy and radiotherapy in 7. Median PSA values before CH-PET/CT and at the end of follow-up were 3.40 ng/ml and 0.91 ng/ml. PSA levels remained stable, decreased or were below measurable levels in 108 patients. PSA levels increased in 48 patients. In 75 of the 156 patients (48%) the treatment plan was changed due to the CH-PET/CT findings. In 33 patients the therapeutic plan was changed from palliative treatment to treatment with curative intent. In 15 patients treatment was changed from curative to palliative. In 8 patients treatment was changed from curative to another strategy and in 2 patients from one palliative strategy to another. In 17 patients the treatment plan was adapted. CONCLUSION: CH-PET/CT has an important impact on the therapeutic strategy in patients with rPCA and can help to determine an appropriate treatment.


Assuntos
Colina/análogos & derivados , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/terapia , Recidiva , Estudos Retrospectivos
18.
Invest Radiol ; 47(2): 121-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21934516

RESUMO

OBJECTIVE: To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. MATERIALS AND METHODS: Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. RESULTS: Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. CONCLUSION: With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on aortic enhancement characteristics at lower CM concentrations than at higher CM concentrations.


Assuntos
Aorta/anatomia & histologia , Aorta/fisiologia , Gadolínio/administração & dosagem , Angiografia por Ressonância Magnética/métodos , Cloreto de Sódio/administração & dosagem , Velocidade do Fluxo Sanguíneo/fisiologia , Quelantes/administração & dosagem , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Humanos , Injeções Intra-Arteriais , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Int J Cardiovasc Imaging ; 28(6): 1533-43, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21898186

RESUMO

To assess whether a scan triggering technique based on the slope of the time-attenuation curve combined with table speed optimization may improve arterial enhancement in aortic CT angiography compared to conventional threshold-based triggering techniques. Measurements of arterial enhancement were performed in a physiologic flow phantom over a range of simulated cardiac outputs (2.2-8.1 L/min) using contrast media boluses of 80 and 150 mL injected at 4 mL/s. These measurements were used to construct computer models of aortic attenuation in CT angiography, using cardiac output, aortic diameter, and CT table speed as input parameters. In-plane enhancement was calculated for normal and aneurysmal aortic diameters. Calculated arterial enhancement was poor (<150 HU) along most of the scan length using the threshold-based triggering technique for low cardiac outputs and the aneurysmal aorta model. Implementation of the slope-based triggering technique with table speed optimization improved enhancement in all scenarios and yielded good- (>200 HU; 13/16 scenarios) to excellent-quality (>300 HU; 3/16 scenarios) enhancement in all cases. Slope-based triggering with table speed optimization may improve the technical quality of aortic CT angiography over conventional threshold-based techniques, and may reduce technical failures related to low cardiac output and slow flow through an aneurysmal aorta.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Tomografia Computadorizada Multidetectores , Algoritmos , Aneurisma Aórtico/fisiopatologia , Aortografia/instrumentação , Velocidade do Fluxo Sanguíneo , Débito Cardíaco , Simulação por Computador , Meios de Contraste , Humanos , Modelos Lineares , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores/instrumentação , Imagens de Fantasmas , Projetos Piloto , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Fluxo Sanguíneo Regional , Fatores de Tempo
20.
Abdom Imaging ; 37(3): 457-64, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21870116

RESUMO

PURPOSE: To determine if MR cholangiography with Gd-EOB-DTPA can be used to assess cystic duct patency and to establish normal time range for reflux of contrast material into the cystic duct/gallbladder. MATERIALS AND METHODS: This retrospective study is HIPAA-compliant and IRB-approved with waiver for informed consent granted. From September 2008 to June 2009, 300 patients who underwent Gd-EOB-DTPA-enhanced MR imaging for various clinical indications, not specifically limited to evaluation for acute cholecystitis, were identified. 112 patients were excluded: prior cholecystectomy (n = 93), severe technical limitations (n = 9), or absence of appropriate clinical follow-up (n = 10). 188 total patients (82 male, 106 female, mean age 51.0 years) were included in the final dataset. Time between contrast administration and contrast reflux into the cystic duct/gallbladder on delayed phase imaging was measured. RESULTS: Reflux of contrast into the gallbladder was identified in 130/188 patients (69.1%) on delayed phase imaging. Average time to gallbladder reflux was 15:24 ± 5:51 minutes (range: 6:01-41:05 min). 58/188 patients (30.9%) demonstrated no reflux of contrast into the gallbladder at time of final delayed phase images. Of 58 patients who demonstrated no reflux into cystic duct/gallbladder, 15 patients demonstrated no extrahepatic biliary excretion, limiting evaluation of cystic duct patency. A total of 173 patients demonstrated biliary excretion of contrast with 76% overall sensitivity of detection of cystic duct patency. CONCLUSION: MR cholangiography with hepatobiliary MR contrast agents such as Gd-EOB-DTPA can demonstrate cystic duct patency with high sensitivity. MR protocols can be designed within a clinically feasible timeframe to optimize diagnosis of acute cholecystitis.


Assuntos
Colangiopancreatografia por Ressonância Magnética/métodos , Colecistite Aguda/diagnóstico , Meios de Contraste , Gadolínio DTPA , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colecistite Aguda/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...