1.
Environ Monit Assess ; 185(3): 2595-601, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22797881

RESUMO

A new kinetic method has been developed for the determination of nitrite in fruit juice samples. The method is based on the catalytic effect of nitrite with the oxidation of Nile Blue A (NBA) by KBrO(3) in the sulfuric acid medium. The optimum conditions obtained are 1.2 mM sulfuric acid, 0.034 mM of NBA, 2.8 × 10(-3) M KBrO(3), reaction temperature of 20 °C, and reaction time of 100 s at 595.5 nm. Under the optimized conditions, the method allowed the quantification of nitrite in a range of 0.2-800 µg/mL with a detection limit of 0.02 µg/mL. The method was applied to the determination of nitrite in 15 brands of fruit juice samples.


Assuntos
Bebidas/análise , Poluentes Ambientais/análise , Contaminação de Alimentos/análise , Frutas , Nitritos/análise , Catálise , Cinética , Limite de Detecção , Oxazinas , Oxirredução , Espectrofotometria/métodos , Ácidos Sulfúricos
2.
Environ Monit Assess ; 185(1): 553-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22392614

RESUMO

A new kinetic method has been developed for the determination of iodine in water samples. The method is based on the catalytic effect of I(-) with the oxidation of Indigo Carmine (IC) by KBrO(3) in the sulfuric acid medium. The optimum conditions obtained are 0.16 M sulfuric acid, 1 × 10(-3) M of IC, 1 × 10(-2) M KBrO(3), reaction temperature of 35°C, and reaction time of 80 s at 612 nm. Under the optimized conditions, the method allowed the quantification of I(-) in a range of 12-375 ng/mL with a detection limit of 0.46 ng/mL. The method was applied to the determination of iodine in river and city water samples with the satisfactorily results.


Assuntos
Monitoramento Ambiental/métodos , Iodo/análise , Rios/química , Poluentes Químicos da Água/análise , Cidades , Cinética , Limite de Detecção , Espectrofotometria , Temperatura , Abastecimento de Água/estatística & dados numéricos
3.
Biol Trace Elem Res ; 144(1-3): 1430-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21732074

RESUMO

A simple and sensitive kinetic-spectrophotometric method is developed for the determination of trace amounts of iodine in blood serum samples based on its catalytic effect on the oxidation of Nile Blue A by potassium bromate in sulfuric acid medium and at 25°C. The absorbance is measured at 595.5 nm with the fixed-time method. The optimization of the operating conditions regarding concentration of the reagents, temperature, and interferences are also investigated. The calibration curve is linear over the concentration range between 20.0 to 500.0 ng ml(-1) of iodine with good precision and accuracy. The detection limit of the method is down to 12.0 ng ml(-1). The relative standard deviation for a standard solution of 100.0 ng ml(-1) of iodine is 1.32% (n = 10). The proposed method provides a highly sensitive, selective, and relatively rapid assay for iodine at ultra trace level without any pre-concentration and separation step. The method was applied to the determination of iodine in blood serum samples. The analytical results of the real samples were in excellent agreement with standard method.


Assuntos
Iodo/sangue , Bromatos/análise , Calibragem , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Oxazinas , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta , Ácidos Sulfúricos/química , Temperatura