Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pak J Med Sci ; 40(2ICON Suppl): S53-S57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38328644

RESUMO

Background & Objective: Cerebrovascular Accident (CVA) or stroke, Spinal Cord injury can lead to neurological diseases resulting in major loss in motor function causing hemiplegia or tetraplegia. In 2019, according to The Global Burden of Diseases (GBD) CVA/Stroke is the second leading cause of death and the third leading cause of death and disability combined, globally. Its prevalence vary drastically among South Asian countries. The objective of this study was to determine the effectiveness of Functional Electrical Stimulation (FES) machine on neurologically impaired patients at the Physical Therapy department at IHHN, Karachi, Pakistan. Method: In this retrospective study data was extracted from August 2016 to February 2022 on patients with neurological symptoms i.e. hemiplegia or paraplegia with muscle power of two or less on Manual Muscle Testing (MMT). The parameters for evaluating patients progress pre and post treatment were MMT results and their mobility status. The number of sessions ranged between 40 to 100 sessions of Functional Electrical Stimulation (FES) provided on alternate days according to the patient's need. Result: Data of 51 patients who had completed their treatment were extracted and analyzed. The mean age of patients who completed treatment was 49.62 ± 17.26 years. Out of 51(100%), 30 (58.8%) were male and 21 (41.2%) were female. Pre- and post-treatment median (IQR) showed remarkable improvement in MMT of upper limb muscle (from 1.0 to 4.0) and lower limb muscle (from 2.0 to 4.0). Conclusion: FES cycling is an effective treatment for patients with neurological impairments, as it resulted in improvement in both upper and lower limb muscle strength, along with mobility status.

2.
ACS Omega ; 9(1): 227-238, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38222541

RESUMO

In this study, we report on the enhancement of the electrochemical properties of MXene by intercalating C60 nanoparticles between its layers. The aim was to increase the interlayer spacing of MXene, which has a direct effect on capacitance by allowing the electrolyte flow in the electrode. To achieve this, various concentrations of Ti3SiC2 (known as MXene) and C60 nanocomposites were prepared through a hydrothermal process under optimal conditions. The resulting composites were characterized by using X-ray diffraction, scanning electron microscopy, energy dispersive spectroscopy, Raman spectroscopy, and cyclic voltammetry. Electrodes were fabricated using different concentrations of MXene and C60 nanocomposites, and current-voltage (I-V) measurements were performed at various scan rates to analyze the capacitance of pseudo supercapacitors. The results showed the highest capacitance of 348 F g1- for the nanocomposite with a composition of 90% MXene and 10% C60. We introduce MXene-C60 composites as promising electrode materials for supercapacitors and highlight their unique properties. Our work provides a new approach to designing high-performance electrode materials for supercapacitors, which can have significant implications for the development of efficient energy storage systems.

3.
Sci Rep ; 14(1): 1654, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238484

RESUMO

The increasing global demand for energy storage solutions has spurred interest in advanced materials for electrochemical energy storage devices. Transition-metal carbides and nitrides, known as MXenes, are characterized by remarkable conductivity and tunable properties, They have gained significant attention for their potential in energy storage applications. The properties of two-dimensional (2-D) MXenes can be tuned by doping or composite formation. We report a novel Ti3C2Tx/NaF composite prepared via a straightforward hydrothermal process for supercapacitor electrode applications. Three composites with varying NaF concentrations (1%, 3%, and 5%) were synthesized under similar conditions. Structural characterization using X-ray diffraction (XRD) and scanning electron microscopy confirmed the successful formation of the composites, whereas distinct shifts in XRD peaks and new peaks revealed the presence of NaF. Electrochemical performance was evaluated by cyclic voltammetry, galvanostatic charging-discharging, and electrochemical impedance spectroscopy. The composites exhibited pseudo-capacitive behavior with reversible redox reactions during charge and discharge cycles. Specific capacitance of 191 F/g at scan rates of 2 mV/s was measured in 1 M KOH. Electrochemical impedance spectroscopy revealed an escalating impedance factor as NaF content increases within Ti3C2Tx. This study underscores the versatile energy storage potential of Ti3C2Tx/NaF composites, offering insights into their tailored properties and behavior.

4.
Anim Biosci ; 37(2): 253-260, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37641842

RESUMO

OBJECTIVE: The objectives of the present study were to evaluate the effects of once-a-day milk feeding on growth performance and routine behavior of preweaning dairy calves. METHODS: At 22nd day of age, twenty-four Holstein calves were randomly assigned to one of two treatment groups (n = 12/treatment) based on milk feeding frequency (MF): i) 3 L of milk feeding two times a day; ii) 6 L of milk feeding once a day. The milk feeding amount was reduced to half for all calves between 56 and 60 days of age and weaning was done at 60 days of age. To determine the increase in weight and structural measurements, each calf was weighed and measured at 3 weeks of age and then at weaning. The daily behavioral activity of each calf was assessed from the 22nd day of age till weaning (60th day of age) through Nederlandsche Apparatenfabriek (NEDAP) software providing real-time data through a logger fitted on the calf's foot. RESULTS: There was no interaction (p≥0.17) between MF and sex of the calves for routine behavioral parameters, body weight and structural measurements. Similarly, there was no effect of MF on routine behavioral parameters, body weight and structural measurements. However, the sex of the calves affected body weight gain in calves. Male calves had 27% greater total body weight and average daily gain than female calves. There was no effect of the sex of the calves on behavioral measurements. Collectively, in the current study, no negative effects of a once-a-day milk feeding regimen were found on routine behavioral and growth parameters of preweaning calves in group housing. CONCLUSION: Once-a-day milk feeding can be safely adopted in preweaning calves from 22nd day of age.

5.
Sci Rep ; 13(1): 21116, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38036611

RESUMO

The field of supercapacitors consistently focuses on research and challenges to improve energy efficiency, capacitance, flexibility, and stability. Low-cost laser-induced graphene (LIG) offers a promising alternative to commercially available graphene for next-generation wearable and portable devices, thanks to its remarkable specific surface area, excellent mechanical flexibility, and exceptional electrical properties. We report on the development of LIG-based flexible supercapacitors with optimized geometries, which demonstrate high capacitance and energy density while maintaining flexibility and stability. Three-dimensional porous graphene films were synthesized, and devices with optimized parameters were fabricated and tested. One type of device utilized LIG, while two other types were fabricated on LIG by coating multi-walled carbon nanotubes (MWCNT) at varying concentrations. Characterization techniques, including scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray diffraction (XRD), Raman spectroscopy, and voltammetry, were employed to analyze the fabricated devices. AFM analysis revealed a surface roughness of 2.03 µm for LIG due to laser treatment. SEM images displayed compact, dense, and porous surface morphology. XRD analysis confirmed the presence of graphene and graphene oxide, which was further supported by energy-dispersive X-ray spectroscopy (EDX) data. Raman spectroscopy indicated that the fabricated samples exhibited distinct D and G bands at 1362 cm-1 and 1579 cm-1, respectively. Cyclic voltammetry (CV) results showed that LIG's capacitance, power density, and energy density were 6.09 mF cm-2, 0.199 mW cm-2, and 3.38 µWh cm-2, respectively, at a current density of 0.2 mA cm-2. The LIG-MWCNT coated electrode exhibited a higher energy density of 6.05 µWh cm-2 and an areal-specific capacitance of 51.975 mF cm-2 compared to the LIG-based devices. The fabricated device has potential applications in smart electronics, nanorobotics, microelectromechanical systems (MEMS), and wearable and portable electronics.

6.
Sci Rep ; 13(1): 17080, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37816819

RESUMO

A series of carbon-doped ZnO [Zn1-yCyO (0.00 ≤ y ≤ 0.10)] nanorods were synthesized using a cost-effective low-temperature (85 °C) dip coating technique. X-ray diffractometer scans of the samples revealed the hexagonal structure of the C-doped ZnO samples, except for y = 0.10. XRD analysis confirmed a decrease in the unit cell volume after doping C into the ZnO matrix, likely due to the incorporation of carbon at oxygen sites (CO defects) resulting from ionic size differences. The morphological analysis confirmed the presence of hexagonal-shaped nanorods. X-ray photoelectron spectroscopy identified C-Zn-C bonding, i.e., CO defects, Zn-O-C bond formation, O-C-O bonding, oxygen vacancies, and sp2-bonded carbon in the C-doped ZnO structure with different compositions. We analyzed the deconvoluted PL visible broadband emission through fitted Gaussian peaks to estimate various defects for electron transition within the bandgap. Raman spectroscopy confirmed the vibrational modes of each constituent. We observed a stronger room-temperature ferromagnetic nature in the y = 0.02 composition with a magnetization of 0.0018 emu/cc, corresponding to the highest CO defects concentration and the lowest measured bandgap (3.00 eV) compared to other samples. Partial density of states analysis demonstrated that magnetism from carbon is dominant due to its p-orbitals. We anticipate that if carbon substitutes oxygen sites in the ZnO structure, the C-2p orbitals become localized and create two holes at each site, leading to enhanced p-p type interactions and strong spin interactions between carbon atoms and carriers. This phenomenon can stabilize the long-range order of room-temperature ferromagnetism properties for spintronic applications.

7.
Sci Rep ; 13(1): 14218, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37648799

RESUMO

High capacitance devices (Supercapacitors) fabricated using two-dimensional materials such as Graphene and its composites are attracting great attention of the research community, recently. Synthesis of 2D materials and their composites with high quality is desirable for the fabrication of 2D materials-based supercapacitors. Ultrasonic Assisted Liquid Phase Exfoliation (UALPE) is one of the widely used techniques for the synthesis of graphene. In this article, we report the effect of variation in sonication time on the exfoliation of graphite powder to extract a sample with optimal properties well suited for supercapacitors applications. Three different graphite powders (hereafter termed as sample A, sample B, and sample C) were sonicated for duration of 24 h, 48 h and 72 h at 60 °C. The exfoliation of graphite powder into graphene, GO and GrO was studied using XRD and RAMAN. AFM and SEM were further used to examine the layered structure of the synthesized nanocomposite. UV-visible spectroscopy and cyclic voltammetery were used to measure the band gaps, and capacitive behavior of the samples. Sample B exhibited a remarkable specific capacitance of 534.53 F/g with charge specific capacity of 530.1 C/g at 1 A/g and energy density of 66 kW/kg. Power density varied 0.75 kWh/kg to 7.5 kWh/kg for a variation in current density from 1 to 10 A/g. Sample B showed capacitive retention of 94%, the lowest impedance and highest degree of exfoliation and conductivity as compared to the other two samples.

8.
Colloids Surf B Biointerfaces ; 225: 113241, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36893662

RESUMO

Natural enzymes possess several drawbacks which limits their application in industries, wastewater remediation and biomedical field. Therefore, in recent years researchers have developed enzyme mimicking nanomaterials and enzymatic hybrid nanoflower which are alternatives of enzyme. Nanozymes and organic inorganic hybrid nanoflower have been developed which mimics natural enzymes functionalities such as diverse enzyme mimicking activities, enhanced catalytic activities, low cost, ease of preparation, stability and biocompatibility. Nanozymes include metal and metal oxide nanoparticles mimicking oxidases, peroxidases, superoxide dismutase and catalases while enzymatic and non-enzymatic biomolecules were used for preparing hybrid nanoflower. In this review nanozymes and hybrid nanoflower have been compared in terms of physiochemical properties, common synthetic routes, mechanism of action, modification, green synthesis and application in the field of disease diagnosis, imaging, environmental remediation and disease treatment. We also address the current challenges facing nanozyme and hybrid nanoflower research and the possible way to fulfil their potential in future.


Assuntos
Nanopartículas Metálicas , Nanoestruturas , Nanoestruturas/química , Óxidos , Metais , Superóxido Dismutase , Catálise
9.
Materials (Basel) ; 15(21)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36363438

RESUMO

With the growth of the manufacturing industry, the demand for alloy materials with high hardness, toughness, and impact strength has increased. Since products from such alloy materials are extremely difficult to manufacture with high accuracy and reduced surface roughness using traditional machining techniques, wire electric discharge machining can be used to machine such complex parts with more precision. In this case-study-based research, machining factors such as current, pulse-on time, and voltage are studied to determine their effects on the material removal rate for AISI 1045 medium carbon steel. The Taguchi L9 orthogonal array is used in the design of experiments for optimization. Statistical techniques such as analysis of variance and signal-to-noise ratio are used to identify the control parameters that matter most in bringing about optimal results. Based on the results, the current is the most crucial control variable in this investigation. Moreover, the maximum material removal rate obtained was 0.7112 mm3/min with the obtained optimized values of current (I) = 16 A, voltage (V) = 50 V, and pulse-on time (Ton) = 100 µs.

10.
Cyborg Bionic Syst ; 2022: 9763420, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36285318

RESUMO

Nanopipette-based observation of intracellular biochemical processes is an important approach to revealing the intrinsic characteristics and heterogeneity of cells for better investigation of disease progression or early disease diagnosis. However, the manual operation needs a skilled operator and faces problems such as low throughput and poor reproducibility. This paper proposes an automated nanopipette-based microoperation system for cell detection, three-dimensional nonovershoot positioning of the nanopipette tip in proximity to the cell of interest, cell approaching and proximity detection between nanopipette tip and cell surface, and cell penetration and detection of the intracellular reactive oxygen species (ROS). A robust focus algorithm based on the number of cell contours was proposed for adherent cells, which have sharp peaks while retaining unimodality. The automated detection of adherent cells was evaluated on human umbilical cord vein endothelial cells (HUVEC) and NIH/3T3 cells, which provided an average of 95.65% true-positive rate (TPR) and 7.59% false-positive rate (FPR) for in-plane cell detection. The three-dimensional nonovershoot tip positioning of the nanopipette was achieved by template matching and evaluated under the interference of cells. Ion current feedback was employed for the proximity detection between the nanopipette tip and cell surface. Finally, cell penetration and electrochemical detection of ROS were demonstrated on human breast cancer cells and zebrafish embryo cells. This work provides a systematic approach for automated intracellular sensing for adherent cells, laying a solid foundation for high-throughput detection, diagnosis, and classification of different forms of biochemical reactions within single cells.

11.
Clin Nutr ; 38(4): 1561-1569, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30170781

RESUMO

OBJECTIVE: The aim of this trial was to characterize the beneficial effects of probiotics on decreasing endotoxin levels and other cardiometabolic parameters in Arab patients with type 2 diabetes mellitus (T2DM). METHODS: Saudi adults with naïve T2DM (n = 30; 12 males and 18 females) were randomly allocated to receive twice daily placebo or 2.5 × 109 cfu/g of Ecologic®Barrier (multi-strain probiotics; n = 31; 14 males and 17 females) in a double-blind manner over a 6 month period, respectively. Anthropometrics were measured and fasting blood samples were collected to analyze endotoxin, glycemic parameters [glucose, insulin, c-peptide and homeostasis model assessment for insulin resistance (HOMA-IR)], lipids [triglycerides, total cholesterol, low and high-density lipoprotein (LDL and HDL, respectively) cholesterol and total/HDL-cholesterol ratio], inflammatory markers [tumor-necrosis factor-alpha (TNF-α), interleukin-6 (IL-6) and C-reactive protein (CRP)] and adipocytokines [leptin, adiponectin and resistin] at baseline and after 3 and 6 months of intervention. RESULTS: Multi-strain probiotics supplementation for 6 months caused a significant decrease in circulating levels of endotoxin by almost 70% over 6 months, as well as glucose (38%), insulin (38%), HOMA-IR (64%), triglycerides (48%), total cholesterol (19%), total/HDL-cholesterol ratio (19%), TNF-α (67%), IL-6 (77%), CRP (53%), resistin (53%), and a significant increase in adiponectin (72%) as compared with baseline. Only HOMA-IR had a clinically significant reduction (-3.4, 64.2%) in the probiotics group as compared to placebo group at all time points. No other clinically significant changes were observed between the probiotic or placebo group at 3 and 6 months in other markers. CONCLUSION: Multi-strain probiotic supplementation over 6 months as a monotherapy significantly decreased HOMA-IR in T2DM patients, with the probiotic treatment group highlighting reduced inflammation and improved cardiometabolic profile. As such, multi-strain probiotics is a promising adjuvant anti-diabetes therapy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01765517.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2 , Endotoxinas/sangue , Inflamação/sangue , Probióticos , Adipocinas/sangue , Diabetes Mellitus Tipo 2/dietoterapia , Diabetes Mellitus Tipo 2/metabolismo , Método Duplo-Cego , Feminino , Humanos , Insulina/sangue , Resistência à Insulina/fisiologia , Lipídeos/sangue , Masculino , Placebos , Probióticos/administração & dosagem , Probióticos/farmacologia , Probióticos/uso terapêutico
12.
Scanning ; 2018: 3979576, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29692874

RESUMO

An efficient and adaptive boundary tracking method is developed to confine area of interest for high-efficiency local scanning. By using a boundary point determination criterion, the scanning tip is steered with a sinusoidal waveform while estimating azimuth angle and radius ratio of each boundary point to accurately track the boundary of targets. A local scan region and path are subsequently planned based on the prior knowledge of boundary tracking to reduce the scan time. Boundary tracking and local scanning methods have great potential not only for fast dimension measurement but also for sample surface topography and physical characterization, with only scanning region of interest. The performance of the proposed methods was verified by using the alternate current mode scanning ion-conductance microscopy, tapping, and PeakForce modulation atomic force microscopy. Experimental results of single/multitarget boundary tracking and local scanning of target structures with complex boundaries demonstrate the flexibility and validity of the proposed method.

13.
Sensors (Basel) ; 18(1)2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29301265

RESUMO

Sidewall roughness measurement is becoming increasingly important in the micro-electromechanical systems and nanoelectronics devices. Atomic force microscopy (AFM) is an emerging technique for sidewall scanning and roughness measurement due to its high resolution, three-dimensional imaging capability and high accuracy. We report an AFM sidewall imaging method with a quartz tuning fork (QTF) force sensor. A self sensing and actuating force sensor is fabricated by microassembling a commercial AFM cantilever (tip apex radius ≤10 nm) to a QTF. The attached lightweight cantilever allows high-sensitivity force detection (7.4% Q factor reduction) and sidewall imaging with high lateral resolution. Owing to its unique configuration, the tip of the sensor can detect sidewall surface orthogonally during imaging, which reduces lateral friction. In experiments, sidewalls of a micro-electro-mechanical system (MEMS) structure fabricated by deep reactive ion etching process and a standard step grating are scanned and the sidewall roughness, line edge roughness and sidewall angles are measured.

14.
Langmuir ; 33(11): 2725-2733, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28263608

RESUMO

We report high-resolution multiparametric kelvin probe force microscopy (MP-KPFM) measurements for the simultaneous quantitative mapping of the contact potential difference (CPD) and nanomechanical properties of the sample in single-pass mode. This method combines functionalities of the force-distance-based atomic force microscopy and amplitude-modulation (AM) KPFM to perform measurements in single-pass mode. During the tip-sample approach-and-retract cycle, nanomechanical measurements are performed for the retract part of nanoindentation, and the CPD is measured by the lifted probe with a constant tip-sample distance. We compare the performance of the proposed method with the conventional KPFMs by mapping the CPD of multilayer graphene deposited on n-doped silicon, and the results demonstrate that MP-KPFM has comparable performance to AM-KPFM. In addition, the experimental results of a custom-fabricated polymer grating with heterogeneous surfaces validate the multiparametric imaging capability of the MP-KPFM. This method can have potential applications in finding the inherent link between nanomechanical properties and the surface potential of the materials, such as the quantification of the electromechanical response of the deformed piezoelectric materials.

15.
Beilstein J Nanotechnol ; 7: 581-90, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27335748

RESUMO

Spherical domains that readily form at the polystyrene (PS)-water interface were studied and characterized using atomic force microscopy (AFM). The study showed that these domains have similar characteristics to micro- and nanobubbles, such as a spherical shape, smaller contact angle, low line tension, and they exhibit phase contrast and the coalescence phenomenon. However, their insensitivity to lateral force, absence of long-range hydrophobic attraction, and the presence of possible contaminants and scratches on these domains suggested that these objects are most likely blisters formed by the stretched PS film. Furthermore, the analysis of the PS film before and after contact with water suggested that the film stretches and deforms after being exposed to water. The permeation of water at the PS-silicon interface, caused by osmosis or defects present on the film, can be a reasonable explanation for the nucleation of these spherical domains.

16.
Ultramicroscopy ; 158: 8-16, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26103045

RESUMO

A novel atomic force microscope (AFM) dual-probe caliper for critical dimension (CD) metrology has been developed. The caliper is equipped with two facing tilted optical fiber probes (OFPs) wherein each can be used independently to scan either sidewall of micro and nanostructures. The OFP tip with length up to 500 µm (aspect ratio 10:1, apex diameter ⩾10 nm) has unique features of scanning deep trenches and imaging sidewalls of relatively high steps with exclusive profiling possibilities. The caliper arms-OFPs can be accurately aligned with a well calibrated opening distance. The line width, line edge roughness, line width roughness, groove width and CD angles can be measured through serial scan of adjacent or opposite sidewalls with each probe. Capabilities of the presented AFM caliper have been validated through experimental CD measurement results of comb microstructures and AFM calibration grating TGZ3.

17.
Rev Sci Instrum ; 85(12): 123704, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25554298

RESUMO

We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 µm deep) and a microhole (about 14.9 µm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...