Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Res Notes ; 13(1): 548, 2020 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-33243292

RESUMO

OBJECTIVE: We previously reported the pharmaceutical quality of eight brands of 50 mg enteric-coated diclofenac sodium tablet available on the Saudi market. Here, we assess the quality of reference (R1) and four generic (G1-G4) brands of 50 mg immediate-release diclofenac potassium tablet and of reference (R2) and generic (G5) brands of 100 mg sustained-release diclofenac sodium tablet. RESULTS: Weight variation (range as % difference from mean), active substance content (mean (SD) as % difference from label), breaking force [mean (SD)], and friability (as % weight loss) were 95-104% and 99-102%, 100.9% (3.4%) and 105.6 (4.2%), 12.2 (1.3) and 12.9 (1.8) kg, and 0.0014% and 0.0012%, for R1 and R2, respectively. For G1-G5, they were ≤ ± 2%, 98.8% (2.7%) to 109.2% (3.8%), 6.4 (0.6) to 13.3 (1.0) kg, and 0.0007% to 0.0261%, respectively. R1 and G1-G4 disintegrated within 04:50-17:20 min: seconds and released a mean of 89-100% of label active substance content by 60 min in buffer (pH 6.8). R2 and G5 did not disintegrate or dissolve in 0.1 N HCl for 2 h, disintegrated in buffer (pH 6.8) in 01:58-02:15 h: minutes, and fulfilled dissolution criteria (pH 7.5) for both United States Pharmacopoeia test-1 and test-2. Thus all seven brands met pre-specified quality criteria.


Assuntos
Diclofenaco , Farmácia , Química Farmacêutica , Arábia Saudita , Solubilidade , Comprimidos , Comprimidos com Revestimento Entérico
2.
BMC Res Notes ; 13(1): 428, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32928294

RESUMO

OBJECTIVE: To evaluate in vitro quality of enteric-coated 50 mg diclofenac sodium tablet formulations on Saudi market. RESULTS: A reference and seven generic (G1-7) formulations were commercially available in December 2019/January 2020 and were assessed within 25-75% of manufacture-expiration period. Weight variation (range as% difference from mean, n = 20), active substance content (ASC, mean (SD) as% difference from label, n = 20), hardness (mean (SD), n = 10), and friability (% weight loss, n = 20) were 97-103%, 102.0% (3.4%), 15.4 (1.1) kg, and 0.24%, respectively, for the reference. For G2-7, they were ≤ ±5%, 98.6% (4.0%) to 109.9% (1.8%), 11.9 (0.9) to 18.3 (0.8) kg, and ≤ 0.00 to 0.75%, respectively. G1 ASC, hardness, and friability were 111.3% (1.7%), 20.1 (1.7) kg, and 1.10%, respectively. Disintegration time (n = 6) and dissolution profile (n = 8) were also determined. No formulation disintegrated or released ˃ 0.1% of label ASC in 0.1 N HCl for 2 h. The reference disintegrated in 15:00 min:seconds and released a mean (range) of 100% (99-103%) of label ASC by 45 min in phosphate buffer (pH = 6.8). G1-7 disintegrated in 8:53 to 20:37 min:seconds and released 81% (69-90%) (G1) to 109%. Except for borderline performance of G1, all formulations passed in vitro quality tests according to United States Pharmacopoeia.


Assuntos
Química Farmacêutica , Diclofenaco , Arábia Saudita , Solubilidade , Comprimidos , Comprimidos com Revestimento Entérico
3.
BMC Pharmacol Toxicol ; 18(1): 78, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29216899

RESUMO

BACKGROUND: The extents of generic-reference and generic-generic average bioequivalence and intra-subject variation of on-market drug products have not been prospectively studied on a large scale. METHODS: We assessed bioequivalence of 42 generic products of 14 immediate-release oral drugs with the highest number of generic products on the Saudi market. We conducted 14 four-sequence, randomized, crossover studies on the reference and three randomly-selected generic products of amlodipine, amoxicillin, atenolol, cephalexin, ciprofloxacin, clarithromycin, diclofenac, ibuprofen, fluconazole, metformin, metronidazole, paracetamol, omeprazole, and ranitidine. Geometric mean ratios of maximum concentration (Cmax) and area-under-the-concentration-time-curve, to last measured concentration (AUCT), extrapolated to infinity (AUCI), or truncated to Cmax time of reference product (AUCReftmax) were calculated using non-compartmental method and their 90% confidence intervals (CI) were compared to the 80.00%-125.00% bioequivalence range. Percentages of individual ratios falling outside the ±25% range were also determined. RESULTS: Mean (SD) age and body-mass-index of 700 healthy volunteers (28-80/study) were 32.2 (6.2) years and 24.4 (3.2) kg/m2, respectively. In 42 generic-reference comparisons, 100% of AUCT and AUCI CIs showed bioequivalence, 9.5% of Cmax CIs barely failed to show bioequivalence, and 66.7% of AUCReftmax CIs failed to show bioequivalence/showed bioinequivalence. Adjusting for 6 comparisons, 2.4% of AUCT and AUCI CIs and 21.4% of Cmax CIs failed to show bioequivalence. In 42 generic-generic comparisons, 2.4% of AUCT, AUCI, and Cmax CIs failed to show bioequivalence, and 66.7% of AUCReftmax CIs failed to show bioequivalence/showed bioinequivalence. Adjusting for 6 comparisons, 2.4% of AUCT and AUCI CIs and 14.3% of Cmax CIs failed to show bioequivalence. Average geometric mean ratio deviation from 100% was ≤3.2 and ≤5.4 percentage points for AUCI and Cmax, respectively, in both generic-reference and generic-generic comparisons. Individual generic/reference and generic/generic ratios, respectively, were within the ±25% range in >75% of individuals in 79% and 71% of the 14 drugs for AUCT and 36% and 29% for Cmax. CONCLUSIONS: On-market generic drug products continue to be reference-bioequivalent and are bioequivalent to each other based on AUCT, AUCI, and Cmax but not AUCReftmax. Average deviation of geometric mean ratios and intra-subject variations are similar between reference-generic and generic-generic comparisons. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01344070 (registered April 3, 2011).


Assuntos
Medicamentos Genéricos/farmacocinética , Administração Oral , Adulto , Área Sob a Curva , Estudos Cross-Over , Feminino , Voluntários Saudáveis , Humanos , Masculino , Equivalência Terapêutica
4.
Sci Rep ; 7(1): 15270, 2017 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-29127379

RESUMO

Activating mutations in the Wnt pathway are a characteristic feature of colorectal cancer (CRC). The R-spondin (RSPO) family is a group of secreted proteins that enhance Wnt signaling and RSPO2 and RSPO3 gene fusions have been reported in CRC. We have previously shown that Wnt pathway blockers exhibit potent combinatorial activity with taxanes to inhibit tumor growth. Here we show that RSPO3 antagonism synergizes with paclitaxel based chemotherapies in patient-derived xenograft models (PDX) with RSPO3 fusions and in tumors with common CRC mutations such as APC, ß-catenin, or RNF43. In these latter types of tumors that represent over 90% of CRC, RSPO3 is produced by stromal cells in the tumor microenvironment and the activating mutations appear to sensitize the tumors to Wnt-Rspo synergy. The combination of RSPO3 inhibition and taxane treatment provides an approach to effectively target oncogenic WNT signaling in a significant number of patients with colorectal and other intestinal cancers.


Assuntos
Hidrocarbonetos Aromáticos com Pontes/farmacologia , Neoplasias Colorretais , Mutação , Proteínas de Neoplasias , Paclitaxel/farmacologia , Taxoides/farmacologia , Trombospondinas , Microambiente Tumoral/efeitos dos fármacos , Via de Sinalização Wnt , Animais , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/genética , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Proteínas de Neoplasias/antagonistas & inibidores , Proteínas de Neoplasias/genética , Proteínas de Neoplasias/metabolismo , Trombospondinas/antagonistas & inibidores , Trombospondinas/genética , Trombospondinas/metabolismo , Microambiente Tumoral/genética , Via de Sinalização Wnt/efeitos dos fármacos , Via de Sinalização Wnt/genética , Ensaios Antitumorais Modelo de Xenoenxerto
5.
J Negat Results Biomed ; 16(1): 10, 2017 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-28535819

RESUMO

BACKGROUND: Medication effect is the sum of its drug, placebo, and drug*placebo interaction effects. It is conceivable that the interaction effect involves modulating drug bioavailability; it was previously observed that being aware of caffeine ingestion may prolong caffeine plasma half-life. This study was set to evaluate such concept using different drugs. METHODS: Balanced single-dose, two-period, two-group, cross-over design was used to compare the pharmacokinetics of oral cephalexin, ibuprofen, and paracetamol, each described by its name (overt) or as placebo (covert). Volunteers and study coordinators were deceived as to study aim. Drug concentrations were determined blindly by in-house, high performance liquid chromatography assays. Terminal-elimination half-life (t½) (primary outcome), maximum concentration (Cmax), Cmax first time (Tmax), terminal-elimination-rate constant (λ), area-under-the-concentration-time-curve, to last measured concentration (AUCT), extrapolated to infinity (AUCI), or to Tmax of overt drug (AUCOverttmax), and Cmax/AUCI were calculated blindly using standard non-compartmental method. Covert-vs-overt effect on drug pharmacokinetics was evaluated by analysis-of-variance (ANOVA, primary analysis), 90% confidence interval (CI) using the 80.00-125.00% bioequivalence range, and percentage of individual pharmacokinetic covert/overt ratios that are outside the +25% range. RESULTS: Fifty, 30, and 50 healthy volunteers (18%, 10%, and 6% females, mean (SD) age 30.8 (6.2), 31.4 (6.6), and 31.2 (5.4) years) participated in 3 studies on cephalexin, ibuprofen, and paracetamol, respectively. Withdrawal rate was 4%, 0%, and 4%, respectively. Eighteen blood samples were obtained over 6, 10, and 14 h in each study period of the three drugs, respectively. ANOVA showed no significant difference in any pharmacokinetic parameter for any of the drugs. The 90% CIs for AUCT, AUCI, Cmax, AUCOverttmax, and Cmax/AUCI were within the bioequivalence range, except for ibuprofen Cmax (76.66-98.99), ibuprofen Cmax/AUCI (77.19-98.39), and ibuprofen (45.32-91.62) and paracetamol (51.45-98.96) AUCOverttmax. Out of the 126 individual covert/overt ratios, 2.0-16.7% were outside the +25% range for AUCT, 2.0-4.2% for AUCI, 25.0-44.9% for Cmax, 67.3-76.7% for AUCOverttmax, and 45.8-71.4% for Tmax. CONCLUSIONS: This study couldn't confirm that awareness of drug ingestion modulates its bioavailability. However, it demonstrates the trivial effect of blinding in bioequivalence studies and the extent of bio-variability that would be expected when comparing a drug product to itself. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01501747 (registered Dec 26, 2011).


Assuntos
Preparações Farmacêuticas/metabolismo , Efeito Placebo , Acetaminofen/farmacocinética , Adulto , Disponibilidade Biológica , Cefalexina/farmacocinética , Estudos Cross-Over , Feminino , Humanos , Ibuprofeno/farmacocinética , Masculino , Equivalência Terapêutica , Fatores de Tempo
6.
Arzneimittelforschung ; 57(5): 269-73, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17598698

RESUMO

A randomized, single-dose, crossover study was conducted to assess the bioavailability of two domperidone (CAS 57808-66-9) tablet formulations, Domperidone (test) and a commercially available original preparation (reference) under fasting conditions. A 10 mg dose of each formulation was administered to 36 healthy male volunteers with a one-week washout period, 17 blood samples were collected over 48 h, plasma concentrations of domperidone were analyzed by a locally validated LC-MS-MS assay, and the pharmacokinetic parameters were determined by the standard non-compartmental method. Mean +/- SD maximum concentration (C(max)), time to reach maximum concentration (T(max)), areas under the curve (AUC(0 --> t and AUC(0 --> infininty)), and elimination constant (K(el)) were 17.13 +/- 9.62 and 17.67 +/- 7.97 ng/ml, 0.87 +/- 0.58, and 0.89 +/- 0.33 h, 73.12 +/- 43.37 and 71.45 +/- 35.41 ng x h/ml, 90.32 +/- 48.55 and 87.08 +/- 40.29 ng x h/ml, and 0.069 +/- 0.046 and 0.068 +/- 0.048 h(-1) for the test and reference formulation, respectively. The parametric 90% confidence intervals on the mean difference between log-transformed values of the two formulations were within the acceptable bioequivalence range for AUC(0 --> t) (87.84% to 109.60%), AUC(0 --> infinity) (89.05% to 111.67%) and C(max) (83.28% to 107.50%). ANOVA revealed significant subject's effect for AU4C(0 --> t), AUC((0 -->infinity), C(max), and t1/2 with a ratio of the inter-subject to intra-subject coefficient of variation of 2.10, 1.55, 1.10, and 1.02, respectively. The results indicate that the two formulations are equivalent in relation to the extent and rate of absorption and confirm the previously reported marked intra-individual variations in the pharmacokinetics of domperidone.


Assuntos
Antieméticos/farmacocinética , Domperidona/farmacocinética , Antieméticos/administração & dosagem , Área Sob a Curva , Química Farmacêutica , Cromatografia Líquida , Estudos Cross-Over , Domperidona/administração & dosagem , Método Duplo-Cego , Meia-Vida , Humanos , Masculino , Espectrometria de Massas por Ionização por Electrospray , Comprimidos , Espectrometria de Massas em Tandem , Equivalência Terapêutica
7.
Arzneimittelforschung ; 57(2): 101-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17396620

RESUMO

A randomized, single-dose, crossover study was conducted to assess the bioavailability of two omeprazole (CAS 73590-58-6) capsule formulations, Emilok (test) and a commercially available original preparation (reference), under fasting conditions. A 20 mg dose of each formulation was administered to 36 healthy male volunteers with one-week washout period, 17 blood samples were collected over 12 h, plasma omeprazole concentrations were determined by a locally validated high performance liquid chromatography (HPLC) assay, and omeprazole pharmacokinetic parameters were analyzed by the standard non-compartmental method. Mean +/- SD of Cmax, Tmax, AUC(0 --> t), AUC(0 --> infinity), and t1/2 were 0.41 +/- 0.21 and 0.48 +/- 0.27 microg/ml, 1.98 +/- 1.02 and 1.63 +/- 0.78 h, 0.95 +/- 0.78 and 1.00 +/- 0.90 microg x h/ml, 0.99 +/- 0.81 and 1.04 +/- 0.95 microg x h/ml, and 1.30 +/- 0.64 and 1.14 +/- 0.61 h for the test and reference formulations, respectively. The parametric 90% confidence intervals on mean difference between log-transformed values of the two formulations were within the acceptable bioequivalence range of 80% to 125% for AUC(0 --> t) and AUC(0 --> infinity) (88.63% to 104.98%, and 91.71% to 106.86%, respectively) but not for Cmax (76.27% to 103.63%). ANOVA revealed significant subject's effect for AUC(0 --> t), AUC(0 --> infinity), Cmax, and t1/2 with a ratio of the inter-subject to intra-subject coefficient of variation of 3.66, 3.92, 1.25, and 1.46, respectively. The results confirm the presence of marked individual variations in the pharmacokinetics of omeprazole and indicate that the two formulations are equivalent in relation to the extent but not the rate of absorption.


Assuntos
Antiulcerosos/administração & dosagem , Antiulcerosos/farmacocinética , Omeprazol/administração & dosagem , Omeprazol/farmacocinética , Adulto , Área Sob a Curva , Cápsulas , Química Farmacêutica , Estudos Cross-Over , Meia-Vida , Humanos , Masculino , Equivalência Terapêutica
8.
Ther Drug Monit ; 25(1): 88-92, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12548150

RESUMO

The authors describe a rapid, useful, specific, and very sensitive high-performance liquid chromatographic assay for the determination of fluvastatin (FV) level using atorvastatin as the internal standard (IS). After a simple deproteinization of 1.0 mL of plasma with acetonitrile, the drug and IS were extracted with tert-methyl butyl ether (TMBE). An efficient separation was performed using an 8 mm x 10 cm Nova Pak C(18) 4-microm particle size radial compression cartridge. The mobile phase consisted of an aqueous solution containing 20 mmol/L dibasic sodium dihydrogen phosphate with 1 mmol/L sodium lauryl sulfate adjusted to pH 7 with phosphoric acid and acetonitrile (70:30 v/v) delivered at a flow rate of 1.0 mL/min. The compounds of interest were detected using a fluorescence detector with the excitation wavelength set at 305 nm and the emission at 380 nm. Under these conditions, the retention times for FV and IS were 8.8 and 10.6 minutes, respectively. The concentration of FV in plasma was linear (r > 0.999) for the wide range that was examined (0.5-1,000 ng/mL). The recovery ranged from 88% to 96%. This sensitive, rapid, and simple analytical method gives accurate results over the wide range of concentrations examined. This method is used currently for clinical therapeutic monitoring and pharmacokinetic studies of FV in patients with hypercholesterolemia.


Assuntos
Ácidos Graxos Monoinsaturados/sangue , Indóis/sangue , Cromatografia Líquida de Alta Pressão/métodos , Ácidos Graxos Monoinsaturados/uso terapêutico , Fluvastatina , Humanos , Hipercolesterolemia/sangue , Hipercolesterolemia/tratamento farmacológico , Indóis/uso terapêutico , Modelos Lineares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...