Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 62(7): B79-B86, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37132889

RESUMO

Based on pulsed DC sputter deposition of hydrogenated carbon, an absorber optical coating with maximized broadband infrared absorptance is reported. Enhanced broadband (2.5-20 µm) infrared absorptance (>90%) with reduced infrared reflection is achieved by combining a low-absorptance antireflective (hydrogenated carbon) overcoat with a broadband-absorptance carbon underlayer (nonhydrogenated). The infrared optical absorptance of sputter deposited carbon with incorporated hydrogen is reduced. As such, hydrogen flow optimization to minimize reflection loss, maximize broadband absorptance, and achieve stress balance is described. Application to complementary metal-oxide-semiconductor (CMOS) produced microelectromechanical systems (MEMS) thermopile device wafers is described. A 220% increase in thermopile output voltage is demonstrated, in agreement with modeled prediction.

2.
Comput Methods Programs Biomed ; 200: 105826, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33187733

RESUMO

BACKGROUND: In this work we describe a breath emulator system, used to simulate temporal characteristics of exhaled carbon dioxide (CO2) concentration waveform versus time simulating how much CO2 is present at each phase of the human lung respiratory process. The system provides a method for testing capnometers incorporating fast response non-dispersive infrared (NDIR) CO2 gas sensing devices - in a clinical setting, capnography devices assess ventilation which is the CO2 movement in and out of the lungs. A mathematical model describing the waveform of the expired CO2 characteristic and influence of CO2 gas sensor noise factors and speed of response is presented and compared with measured and emulated data. OBJECTIVE: A range of emulated capnogram temporal waveforms indicative of normal and restricted respiratory function demonstrated. The system can provide controlled introduction of water vapour and/ or other gases, simulating the influence of water vapour in exhaled breath and presence of other gases in a clinical setting such as anaesthetic agents (eg N2O). This enables influence of water vapour and/ or other gases to be assessed and modelled in the performance of CO2 gas sensors incorporated into capnography systems. As such the breath emulator provides a means of controlled testing of capnometer CO2 gas sensors in a non-clinical setting, allowing device optimisation before use in a medical environment. METHODS: The breath emulator uses a unique combination of mass flow controllers, needle valves and a fast acting switchable pneumatic solenoid valve (FASV), used to controllably emulate exhaled CO2 temporal waveforms for normal and restricted respiratory function. Output data from the described emulator is compared with a mathematical model using a range of input parameters such as time constants associated with inhalation/ exhalation for different parts of the respiratory cycle and CO2 concentration levels. Sensor noise performance is modelled, taking into account input parameters such as sampling period, sensor temperature, sensing light throughput and pathlength. RESULTS: The system described here produces realistic human capnographic waveforms and has the capability to emulate various waveforms associated with chronic respiratory diseases and early stage detection of exacerbations. The system has the capability of diagnosing medical conditions through analysis of CO2 waveforms. Demonstrated in this work the emulator has been used to test NDIR gas sensor technology deployed in capnometer devices prior to formal clinical trialling.


Assuntos
Capnografia , Dióxido de Carbono , Testes Respiratórios , Simulação por Computador , Humanos , Pulmão , Respiração
3.
Sensors (Basel) ; 20(14)2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-32660151

RESUMO

Concept, design and practical implementation of a miniaturized spectrophotometer, utilized as a mid-infrared-based multi gas sensor is described. The sensor covers an infrared absorption wavelength range of 2.9 to 4.8 um, providing detection capabilities for carbon dioxide, carbon monoxide, nitrous oxide, sulphur dioxide, ammonia and methane. A lead selenide photo-detector array and customized MEMS-based micro-hotplate are used as the detector and broadband infrared source, respectively. The spectrophotometer optics are based on an injection moulded Schwarzschild configuration incorporating optical pass band filters for the spectral discrimination. This work explores the effects of using both fixed-line pass band and linear variable optical filters. We report the effectiveness of this low-power-consumption miniaturized spectrophotometer as a stand-alone single and multi-gas sensor, usage of a distinct reference channel during gas measurements, development of ideal optical filters and spectral control of the source and detector. Results also demonstrate the use of short-time pulsed inputs as an effective and efficient way of operating the sensor in a low-power-consumption mode. We describe performance of the spectrometer as a multi-gas sensor, optimizing individual component performances, power consumption, temperature sensitivity and gas properties using modelling and customized experimental procedures.

4.
Ultrasonics ; 68: 54-60, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26913377

RESUMO

A flexible and low profile ultrasonic transducer was fabricated for non-destructive testing (NDT) applications by DC sputtering of 3 µm thick, c-axis oriented, ZnO film on 50 µm aluminium foil. Due to the thin foil-based construction, the transducer can be applied to curved objects and used in sites of restricted accessibility. The device has been used to demonstrate detection of simulated defects in a 45 mm diameter steel pipe, and for thickness measurement on a 3.1 mm thick flat carbon steel plate. Centre frequency measured on the flat plate was 24-29 MHz, with -6 dB bandwidth 4-7 MHz. The pulse duration depended on the couplant, at best 3 cycles or 0.12 µs using SONO Ultragel or epoxy couplant. Transducer performance was found to be comparable to a commercial 10 MHz piezoelectric ultrasonic transducer.

5.
Rev Sci Instrum ; 85(2): 024502, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593375

RESUMO

A prototype of a scalable and potentially low-cost stacked array piezoelectric deformable mirror (SA-PDM) with 35 active elements is presented in this paper. This prototype is characterized by a 2 µm maximum actuator stroke, a 1.4 µm mirror sag (measured for a 14 mm × 14 mm area of the unpowered SA-PDM), and a ±200 nm hysteresis error. The initial proof of concept experiments described here show that this mirror can be successfully used for shaping a high power laser beam in order to improve laser machining performance. Various beam shapes have been obtained with the SA-PDM and examples of laser machining with the shaped beams are presented.

6.
Soc Sci Med ; 90: 63-71, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23746610

RESUMO

Although scholars have noted the connection between appearance and assumptions of health, the degree to which these assumptions matter for establishing authority in social interaction remains less clear. Using a theoretical framework involving "bodily capital"--that is, the value generated from appearance, attractiveness, and physical ability--I investigate the role of appearance in the U.S. fitness industry. Drawing on data from interviews with 26 personal trainers and 25 clients between 2010 and 2011, I find that a trainer's fit-appearing physique imbues their interactions with a degree of moral and health authority. This corporeal credibility engenders trust among clients and allows exercise to be understood as a form of health work. The implications for academics and medical practitioners reach beyond the gym setting and extend recent research linking appearance to health, authority, and medical credibility.


Assuntos
Estética , Academias de Ginástica , Aptidão Física , Relações Profissional-Paciente , Valores Sociais , Adolescente , Adulto , Idoso , Atitude Frente a Saúde , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Confiança , Estados Unidos , Adulto Jovem
7.
Artigo em Inglês | MEDLINE | ID: mdl-22899129

RESUMO

High-frequency ultrasound is needed for medical imaging with high spatial resolution. A key issue in the development of ultrasound imaging arrays to operate at high frequencies (≥30 MHz) is the need for photolithographic patterning of array electrodes. To achieve this directly on 1-3 piezocomposite, the material requires not only planar, parallel, and smooth surfaces, but also an epoxy composite filler that is resistant to chemicals, heat, and vacuum. This paper reports, first, on the surface finishing of 1-3 piezocomposite materials by lapping and polishing. Excellent surface flatness has been obtained, with an average surface roughness of materials as low as 3 nm and step heights between ceramic/polymer of ∼80 nm. Subsequently, high-frequency array elements were patterned directly on top of these surfaces using a photolithography process. A 30-MHz linear array electrode pattern with 50-µm element pitch has been patterned on the lapped and polished surface of a high-frequency 1-3 piezocomposite. Excellent electrode edge definition and electrical contact to the composite were obtained. The composite has been lapped to a final thickness of ∼55 µm. Good adhesion of electrodes on the piezocomposite has been achieved and electrical impedance measurements have demonstrated their basic functionality. The array was then packaged, and acoustic pulse-echo measurements were performed. These results demonstrate that direct patterning of electrodes by photolithography on 1-3 piezocomposite is feasible for fabrication of high-frequency ultrasound arrays. Furthermore, this method is more conducive to mass production than other reported array fabrication techniques.


Assuntos
Transdutores , Ultrassonografia/instrumentação , Óxido de Alumínio/química , Impedância Elétrica , Eletrodos , Microtecnologia/instrumentação
8.
Artigo em Inglês | MEDLINE | ID: mdl-23443710

RESUMO

Miniature ultrasound transducer arrays that can operate at frequencies above 30 MHz are needed for high-resolution medical imaging. One way to achieve this is with a kerfless structure based on 1-3 connectivity piezocomposite with the electrodes defined by photolithography. To achieve this, not only does the composite need planar, parallel, and smooth surfaces, but it must also be made with an epoxy filler compatible with the chemicals, heat, and vacuum required for photolithography. This paper reports full characterization of an epoxy suitable for fine-scale kerfless array fabrication, including photolithographic processing. Material properties have been investigated as a function of cure temperature and for compatibility with solvents. By increasing the cure temperature, the crosslinking between the epoxy and the hardener in- creases, resulting in a higher glass transition temperature. The cured epoxy consequently has better resistance to both heat and solvents. An elevated cure temperature, near 100°C, is required to optimize material properties for photolithography on 1-3 piezocomposites. The acoustic properties of the epoxy have also been studied. These are similar to other epoxies used in piezocomposite fabrication and no significant changes have been observed for the different cure temperatures.


Assuntos
Compostos de Epóxi/análise , Compostos de Epóxi/química , Manufaturas , Sistemas Microeletromecânicos/instrumentação , Transdutores , Desenho de Equipamento , Teste de Materiais , Miniaturização
9.
J Fam Issues ; 31(7): 960-991, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20606708

RESUMO

The family is one of the main areas of social life where the normalization of gay/lesbian identity is incomplete. Most research analyzes the individual and psychological aspects of how families respond to children's disclosure of a gay/lesbian identity, and ignores the social, cultural, and historical contexts. An examination of the cultural discourses, tools, and strategies that are available to parents is necessary for a full understanding of how families respond to gay/lesbian children. We conduct an interpretive content analysis of 29 advice books in order to assess this cultural field and its institutional resources. We find three broad strategies offered to parents: relying on professionals for overcoming the grief of having a gay/lesbian child, normalizing gay/lesbian identity, and utilizing "good" parenting skills. We discuss how these strategies demonstrate the unsettled and often contradictory cultural field of gay/lesbian identity in the family and its implications for sexual identities beyond the closet.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...