1.
Rev Sci Instrum ; 89(10): 10C112, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399970

RESUMO

In the ITER Core Plasma Thomson Scattering, the scattered light collection optics system is installed both inside and outside the diagnostic port under vacuum. The length of the optical path (∼6 m) and the need to shield the neutron and γ radiation increased the complexity of the system with the inclusion of multiple dog-legs, forcing the use of many elements with optical power. Multiple rounds of design have been required in order to satisfy iteratively the system requirements in terms of resolution, aberration, and shielding. The adoption of quasi-free-form reflective surfaces for several mirrors eventually allowed the correct compromise between all conflicting requirements.

2.
Rev Sci Instrum ; 83(10): 10E520, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127027

RESUMO

The ITER equatorial port visible∕infrared wide angle viewing system concept is developed from the measurement requirements. The proposed solution situates 4 viewing systems in the equatorial ports 3, 9, 12, and 17 with 4 views each (looking at the upper target, the inner divertor, and tangentially left and right). This gives sufficient coverage. The spatial resolution of the divertor system is 2 times higher than the other views. For compensation of vacuum-vessel movements, an optical hinge concept is proposed. Compactness and low neutron streaming is achieved by orienting port plug doglegs horizontally. Calibration methods, risks, and R&D topics are outlined.

3.
Rev Sci Instrum ; 81(12): 123508, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21198024

RESUMO

A major upgrade to the ruby Thomson scattering (TS) system has been designed and implemented on the Mega-ampere spherical tokamak (MAST). MAST is equipped with two TS systems, a Nd:YAG laser system and a ruby laser system. Apart from common collection optics each system provides independent measurements of the electron temperature and density profile. This paper focuses on the recent upgrades to the ruby TS system. The upgraded ruby TS system measures 512 points across the major radius of the MAST vessel. The ruby laser can deliver one 10 J 40 ns pulse at 1 Hz or two 5 J pulses separated by 100-800 µs. The Thomson scattered light is collected at F/15 over 1.4 m. This system can resolve small (7 mm) structures at 200 points in both the electron temperature and density channels at high optical contrast; ∼50% modulated transfer function. The system is fully automated for each MAST discharge and requires little adjustment. The estimated measurement error for a 7 mm radial point is <4% of T(e) and <3% of n(e) in the range of 40 eV to 2 keV, for a density of n(e)=2×10(19) m(-3). The photon statistics at lower density can be increased by binning in the radial direction as desired. A new intensified CCD camera design allows the ruby TS system to take two snapshots separated with a minimum time of 230 µs. This is exploited to measure two density and temperature profiles or to measure the plasma background light.

4.
Rev Sci Instrum ; 79(10): 10E730, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044546

RESUMO

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with approximately 10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 degrees to 120 degrees. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.