Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Cardiol ; 132(1): 59-65, 2009 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-18241941

RESUMO

AIMS: To assess safety and efficacy of off-site percutaneous coronary intervention (PCI) in The Dutch invasive cardiovascular system. METHODS AND RESULTS: Descriptive single centre registry of elective and emergency PCI. Setting is a Dutch community hospital, 40 km north of Amsterdam, with an adherent population of 400,000 people. A Clinical follow up of Major Adverse Cardiac and Cerebral Events (MACCE) at 30 days post PCI is performed. The total number of participants eligible for PCI was 781 of whom 545 were men and 236 women. During a two-year period 781 PCI's were performed of which 298 were emergency and 483 elective. Acute complications occurred in 2.1% of participants. MACCE-free was 86.9% in the group with AMI and 95.8% in the elective group. CONCLUSIONS: Off-site PCI is feasible and safe in The Netherlands on the condition that specific key factors for success are taken into consideration.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Hospitais Comunitários/estatística & dados numéricos , Infarto do Miocárdio/terapia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/normas , Clopidogrel , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/epidemiologia , Países Baixos/epidemiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Sistema de Registros , Fatores de Risco , Segurança , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Resultado do Tratamento
2.
Eur J Clin Invest ; 38(7): 462-8, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18489582

RESUMO

BACKGROUND: Several studies have suggested an association between Chlamydophila pneumoniae (Cp) infection and atherosclerosis. A recent study detected Cp DNA in the saphenous vein of 12% of all patients before bypass grafting and in 38% of failed grafts. We used a system in which human veins were perfused with autologous blood under arterial pressure. MATERIALS AND METHODS: Veins were surplus segments of saphenous veins of coronary artery bypass grafting (CABG) patients. Vein grafts were perfused with the blood of the same patient after CABG procedures. Veins were analysed for Cp-specific membrane protein using immunohistochemical and PCR analysis. Veins were analysed before and after perfusion (up to 4 h). The number of Cp positive cells was then quantified in the vein layers. RESULTS: Cp protein was detected within macrophages only. In non-perfused veins, Cp was present in the adventitia in 91% of all patients, in the circular (64%) and longitudinal (23%) layer of the media. No positivity was found in the intima. Perfusion subsequently resulted in a significant increase of Cp positive cells within the circular layer of the media that, however, differed strongly between different patients. Cp DNA was not detected by PCR in those specimens. CONCLUSION: Cp protein was present in 91% of veins, but the number of positive cells differed remarkably between patients. Perfusion of veins resulted in increased infiltration of Cp into the circular layer. These results may point to a putative discriminating role of Cp with respect to graft failure between different patients.


Assuntos
Infecções por Chlamydia/microbiologia , Chlamydophila pneumoniae/isolamento & purificação , Ponte de Artéria Coronária/métodos , Perfusão/métodos , Veia Safena/microbiologia , Doença da Artéria Coronariana/cirurgia , DNA Bacteriano/análise , Humanos , Modelos Biológicos , Reação em Cadeia da Polimerase , Veia Safena/patologia , Veia Safena/transplante , Estatística como Assunto
3.
J Muscle Res Cell Motil ; 26(1): 39-48, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16088376

RESUMO

Changes in myosin heavy chain (MHC) isoform expression and protein composition occur during cardiac disease and it has been suggested that even a minor shift in MHC composition may exert a considerable effect on myocardial energetics and performance. Here an overview is provided of the cellular basis of the energy utilisation in cardiac tissue and novel data are presented concerning the economy of myocardial contraction in diseased atrial and ventricular human myocardium. ATP utilisation and force development were measured at various Ca(2+) concentrations during isometric contraction in chemically skinned atrial trabeculae from patients in sinus rhythm (SR) or with chronic atrial fibrillation (AF) and in ventricular muscle strips from non-failing donor or end-stage failing hearts. Contractile protein composition was analysed by one-dimensional gel electrophoresis. Atrial fibrillation was accompanied by a significant shift from the fast alpha-MHC isoform to the slow beta-MHC isoform, whereas both donor and failing ventricular tissue contained almost exclusively the beta-MHC isoform. Simultaneous measurements of force and ATP utilisation indicated that economy of contraction is preserved in atrial fibrillation and in end-stage human heart failure.


Assuntos
Arritmia Sinusal/fisiopatologia , Fibrilação Atrial/fisiopatologia , Coração/fisiopatologia , Contração Miocárdica , Miocárdio/metabolismo , Cadeias Pesadas de Miosina/metabolismo , Trifosfato de Adenosina/metabolismo , Biópsia , Doença Crônica , Eletroforese em Gel de Poliacrilamida , Feminino , Humanos , Masculino , Contração Miocárdica/fisiologia , Miocárdio/química , Cadeias Pesadas de Miosina/análise , Cadeias Pesadas de Miosina/genética , Isoformas de Proteínas/análise , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo
4.
Perfusion ; 20(2): 121-4, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15918450

RESUMO

The use of mini cardiopulmonary bypass circuits is an emerging technology. The venous and cardiotomy reservoir have been excluded from the circuit. This results in a reduction of the blood contact surface area and of the priming volume. Entrainment of venous air, however, remains a drawback in the widespread acceptance of using these mini circuits. The technique described resolves this problem by automatic removal of venous air, and explains how this mini cardiopulmonary bypass circuit was utilized on a 64-year-old female presented for a mitral valve repair. In the absence of a cardiotomy reservoir, an autotransfusion cell separator was used to process shed blood and, after CPB, the residual pump blood. This mini bypass circuit, with the safety feature to remove automatically venous air, provided an additional degree of protection. In our experience, mini bypass circuits allow us safely to perform cardiopulmonary bypass during valve procedures.


Assuntos
Ponte Cardiopulmonar/instrumentação , Ponte Cardiopulmonar/métodos , Valva Mitral/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade
5.
Cardiovasc Res ; 65(1): 221-9, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15621050

RESUMO

OBJECTIVE: Cardiac energetics and performance depend on the expression level of the fast (alpha-) and slow (beta-) myosin heavy chain (MHC) isoform. In ventricular tissue, the beta-MHC isoform predominates, whereas in atrial tissue a variable mixture of alpha- and beta-MHC is found. In several cardiac diseases, the slow isoform is upregulated; however, the functional implications of this transition in human myocardium are largely unknown. The aim of this study was to determine the relation between contractile properties and MHC isoform composition in healthy human myocardium using the diversity in atrial tissue. METHODS: Isometric force production and ATP consumption were measured in chemically skinned atrial trabeculae and ventricular muscle strips, and rate of force redevelopment was studied using single cardiomyocytes. MHC isoform composition was determined by one-dimensional SDS-gel electrophoresis. RESULTS: Force development in ventricular tissue was about 5-fold more economical, but nine times slower, than in atrial tissue. Significant linear correlations were found between MHC isoform composition, ATP consumption and rate of force redevelopment. CONCLUSION: These results clearly indicate that even a minor shift in MHC isoform expression has considerable impact on cardiac performance in human tissue.


Assuntos
Trifosfato de Adenosina/metabolismo , Função Atrial/fisiologia , Miocárdio/metabolismo , Função Ventricular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Eletroforese em Gel de Poliacrilamida , Átrios do Coração , Ventrículos do Coração , Humanos , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Cadeias Pesadas de Miosina/metabolismo , Isoformas de Proteínas/metabolismo
6.
Anesth Analg ; 98(6): 1586-1594, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15155310

RESUMO

UNLABELLED: Reduction of the inflammatory reaction with the use of heparin coating has been found during and after cardiopulmonary bypass (CPB). The question remains whether this reduced reaction also decreases the magnitude of CPB-induced pulmonary dysfunction. We therefore evaluated the effects of a heparin-coated circuit versus a similar uncoated circuit on pulmonary indices as well as on inflammatory markers of complement activation (C3b/c), elastase-alpha(1)-antitrypsin complex, and secretory phospholipase A(2) (sPLA(2)) during and after CPB. Fifty-one patients were randomly assigned into two groups undergoing coronary artery bypass grafting with either a heparin-coated (Group 1) or an uncoated (Group 2) circuit. During CPB, a continuous positive airway pressure of 5 cm H(2)O and a fraction of inspired oxygen (FIO(2)) of 0.21 were maintained. Differences in favor of the coated circuit were found in pulmonary shunt fraction (P < 0.05), pulmonary vascular resistance index (P < 0.05), and PaO(2)/FIO(2) ratio (P < 0.05) after CPB and in the intensive care unit. During and after CPB, the coated group demonstrated lower levels of sPLA(2). After CPB, C3b/c and the elastase-alpha(1)-antitrypsin complex were significantly less in the coated group (P < 0.001). The coated circuit was associated with a reduced inflammatory response, decreased pulmonary vascular resistance index and pulmonary shunt fraction, and increased PaO(2)/FIO(2) ratio, suggesting that the coated circuit may have beneficial effects on pulmonary function. The correlation with sPLA(2), leukocyte activation, and postoperative leukocyte count suggests reduced activation of pulmonary capillary endothelial cells. IMPLICATIONS: Heparin coating of the extracorporeal circuit reduces the inflammatory response during cardiopulmonary bypass. Analysis of indices of pulmonary function indicates that use of heparin coating may result in less impaired gas exchange.


Assuntos
Ponte Cardiopulmonar/métodos , Materiais Revestidos Biocompatíveis/uso terapêutico , Heparina/uso terapêutico , Mediadores da Inflamação/metabolismo , Pulmão/efeitos dos fármacos , Idoso , Ponte Cardiopulmonar/instrumentação , Materiais Revestidos Biocompatíveis/farmacologia , Método Duplo-Cego , Feminino , Heparina/farmacologia , Humanos , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas/métodos , Testes de Função Respiratória/métodos , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...