Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Fr Allergol (2009) ; 62(4): 431-434, 2022 May.
Artigo em Francês | MEDLINE | ID: mdl-34484471

RESUMO

Vaccination is the most efficient way to fight the Covid epidemic. However, suspicion of severe hypersensitivity to PEG (PolyEthylen Glycol) usually constitutes a vaccine contraindication. We report the case of a patient with a proven allergy to PEG and skin sensitization to the COMIRNATY vaccine (PEG in its composition). He was able to benefit from the vaccine under the 5-step desensitization protocol. Conclusions: Specific allergological management should be offered to patients suspected of severe hypersensitivity to PEG and other vaccine excipients. We propose a solution for Comirnaty administration for patients with a proven severe allergy to PEG.

2.
Ann Dermatol Venereol ; 143(12): 852-855, 2016 Dec.
Artigo em Francês | MEDLINE | ID: mdl-27080820

RESUMO

BACKGROUND: Determining the substance responsible for recurrent fixed drug eruption (FDE) may be difficult in the case of patients on multiple medication. Allergy testing may prove invaluable in such situations, as we demonstrate herein with an original case. PATIENTS AND METHODS: A 49-year-old man presented a rash on the seventh day of treatment with esomeprazole, clarithromycin and amoxicillin prescribed for gastritis involving Helicobacter pylori. The condition regressed spontaneously within a few days, but left three areas of hyperpigmentation. The patient subsequently reported four further episodes consisting of stereotypical reactivation in the areas of the three initial lesions and occurring 24hours after use of clarithromycin (2 episodes) and amoxicillin (2 episodes). The patient resumed proton pump inhibitor therapy (esomeprazole) without incident. Based on history taking, an initial diagnosis was made of multiple fixed drug eruption involving amoxicillin and clarithromycin. The initial skin allergy investigations were negative (patch-tests for amoxicillin and clarithromycin on healthy skin on the patient's back and on the affected area). After discussion, we decided to reintroduce the suspected drugs in succession. Beginning with clarithromycin, 12h after a single dose of 250mg, we noted an erythematous reaction on the pigmented areas, together with a burning sensation. In an identical challenge test with amoxicillin (500mg), the latter drug was perfectly well tolerated, ruling out the diagnosis of FDE to amoxicillin and thus the diagnosis of multiple FDE suggested by the patient history. DISCUSSION: FDEs to macrolides are rare, and herein we report a new case. Our observation confirms the diagnostic value of challenge tests in FDE. These tests should only be performed in the event of non-severe FDE, in other words not in bullous or systemic reactions, and they often constitute the only diagnostic approach possible, since skin tests are rarely positive during investigation for FDE.


Assuntos
Antibacterianos/efeitos adversos , Claritromicina/efeitos adversos , Toxidermias/etiologia , Toxidermias/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro
3.
Ann Dermatol Venereol ; 142 Suppl 1: S13-7, 2015 Jan.
Artigo em Francês | MEDLINE | ID: mdl-25749835

RESUMO

Human microbiota includes all microorganisms, saprophytes and pathogens that colonize our bodies. Recent advances in metagenomic analysis techniques have expanded our knowledge of the microbiota and fundamentally changed our view of its relationships with the immune system. The commensal flora appears to be essential to the development of the immune system, and the diversity of the microbiota is correlated with good health status of individuals. These findings open up new conceptual and therapeutic approaches in chronic inflammatory diseases.


Assuntos
Inflamação/imunologia , Microbiota , Pele/microbiologia , Humanos
4.
Surg Endosc ; 24(9): 2293-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20177915

RESUMO

BACKGROUND: The lack of triangulation of standard endoscopic devices limits the degree of freedom for surgical maneuvers during natural orifice transluminal endoscopic surgery (NOTES). This study explored the feasibility of adapting an intuitively controlled master and slave transluminal endoscopic robot (MASTER) the authors developed to facilitate wedge hepatic resection in NOTES. METHODS: The MASTER consists of a master controller, a telesurgical workstation, and a slave manipulator that holds two end-effectors: a grasper, and a monopolar electrocautery hook. The master controller is attached to the wrist and fingers of the operator and connected to the manipulator by electrical and wire cables. Movements of the operator are detected and converted into control signals driving the slave manipulator via a tendon-sheath power transmission mechanism allowing nine degrees of freedom. Using this system, wedge hepatic resection was performed through the transgastric route on two female pigs under general anesthesia. Entry into the peritoneal cavity was via a 10-mm incision made on the anterior wall of the stomach by the electrocautery hook. Wedge hepatic resection was performed using the robotic grasper and hook. Hemostasis was achieved with the electrocautery hook. After the procedure, the resected liver tissue was retrieved through the mouth using the grasper. RESULTS: Using the MASTER, transgastric wedge hepatic resection was successfully performed on two pigs with no laparoscopic assistance. The entire procedure took 9.4 min (range, 8.5-10.2 min), with 7.1 min (range, 6-8.2 min) spent on excision of the liver tissue. The robotics-controlled device was able to grasp, retract, and excise the liver specimen successfully in the desired plane. CONCLUSION: This study demonstrated for the first time that the MASTER could effectively mitigate the technical constraints normally encountered in NOTES procedures. With it, the triangulation of surgical tools and the manipulation of tissue became easy, and wedge hepatic resection could be accomplished successfully without the need for assistance using laparoscopic instruments.


Assuntos
Hepatectomia/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Cirurgia Endoscópica por Orifício Natural/métodos , Robótica , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Projetos Piloto , Estômago/cirurgia , Suínos , Gravação em Vídeo
5.
Artigo em Inglês | MEDLINE | ID: mdl-19963992

RESUMO

Although the flexible endoscopy has been widely used in the medical field for many years, there is still great potential in improving the endoscopist's capability to perform therapeutic tasks. Tentatively, tools for the flexible endoscope have poor maneuverability and limited Degree Of Freedom (DOF). In this paper, we propose a surgical robotic system MASTER (Master And Slave Transluminal Endoscopic Robot). MASTER is a dexterous and flexible master-slave device which can be used in tandem with a conventional flexible endoscope. Using this robotic system, ESD (Endoscopic Submucosal Dissection) and NOTES (Natural Orifice Transluminal Endoscopic Surgery) have been conducted on in vivo and ex vivo animal trials with promising results.


Assuntos
Endoscópios , Endoscopia/métodos , Robótica/instrumentação , Robótica/métodos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Animais , Engenharia Biomédica , Desenho de Equipamento , Humanos , Fígado/cirurgia , Modelos Animais
6.
Artigo em Inglês | MEDLINE | ID: mdl-19964181

RESUMO

The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.


Assuntos
Cápsulas Endoscópicas , Trato Gastrointestinal/fisiologia , Humanos , Instrumentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...