1.
J Diabetes Sci Technol ; 14(5): 890-895, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-30841743

RESUMO

BACKGROUND: Point-of-care (POC) HbA1c tests hold the promise of reducing the rates of undiagnosed diabetes, provided they exhibit acceptable analytical performance. The precision and total error of the POC (Afinion™ HbA1c Dx) test were investigated using whole blood samples obtained by fingerstick and venipuncture. METHODS: Fingerstick samples spanning the assay range were collected from 61 subjects at three representative POC sites. At each site, six fingerstick samples were obtained from each subject and tested on the POC test across two (Afinion AS100) instruments. Repeatability, between-operator, and between-instrument components of variance were calculated using analysis of variance (ANOVA). Four venous samples (low, threshold, medium, and high HbA1c) were measured in duplicate across three instruments using three reagent lots, twice per day over 20-days. Repeatability, between-run, between-day, between-lot, and between-instrument components of variance were calculated. These fingerstick and venous blood results, combined with estimates of imprecision and bias from a prior investigation, allowed for the calculation of the total coefficient of variation (CV) and total error of the POC test using fingerstick and venous whole blood samples. RESULTS: The total imprecision ranged from 1.30% to 2.03% CV using fingerstick samples and from 1.31% to 1.64% CV using venous samples. The total error ranged from 2.87% to 4.75% using fingerstick samples and from 2.93% to 3.80% using venous samples. CONCLUSIONS: The POC test evaluated here is precise across its measuring range using both fingerstick and venous whole blood. The calculated total error of the test is well under the accepted quality requirement of ≤6%.


Assuntos
Análise Química do Sangue , Diabetes Mellitus/diagnóstico , Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Biomarcadores/sangue , Diabetes Mellitus/sangue , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estados Unidos
2.
J Diabetes Sci Technol ; 14(5): 883-889, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-30854894

RESUMO

BACKGROUND: Point-of-care (POC) hemoglobin A1c (HbA1c) testing has advantages over laboratory testing, but some questions have remained regarding the accuracy and precision of these methods. The accuracy and the precision of the POC Afinion™ HbA1c Dx test were investigated. METHODS: Samples spanning the assay range were collected from prospectively enrolled subjects at three clinical sites. The accuracy of the POC test using fingerstick and venous whole blood samples was estimated via correlation and bias with respect to values obtained by an NGSP secondary reference laboratory (SRL). The precision of the POC test using fingerstick samples was estimated from duplicate results by calculating the coefficient of variation (CV) and standard deviation (SD), and separated into its components using analysis of variance (ANOVA). The precision of the POC test using venous blood was evaluated from samples run in four replicates on each of three test cartridge lots, twice per day for 10 consecutive days. The SD and CV by study site and overall were calculated. RESULTS: Across the assay range, POC test results from fingerstick and venous whole blood samples were highly correlated with results from the NGSP SRL (r = .99). The mean bias was -0.021% HbA1c (-0.346% relative) using fingerstick samples and -0.005% HbA1c (-0.093% relative) using venous samples. Imprecision ranged from 0.62% to 1.93% CV for fingerstick samples and 1.11% to 1.69% CV for venous samples. CONCLUSIONS: The results indicate that the POC test evaluated here is accurate and precise using both fingerstick and venous whole blood.


Assuntos
Análise Química do Sangue , Diabetes Mellitus/diagnóstico , Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Biomarcadores/sangue , Diabetes Mellitus/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Estados Unidos