A A Pract ; 16(5): e01586, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35605173

RESUMO

One-lung ventilation (OLV) can be accomplished utilizing a double-lumen tube (DLT) and an endobronchial blocker (EBB) or intentionally placing a standard endotracheal tube (ETT) into a mainstem bronchus. However, secondary options must be available should the primary method fail. We present a case where an EBB and a fiberoptic bronchoscope (FOB) were successfully passed through a left-sided DLT to reestablish right-lung isolation after the DLT bronchial cuff was surgically damaged. We advocate competency in placing both DLTs and EBBs, as well as having EBBs readily accessible as a secondary isolation method during OLV.


Assuntos
Ventilação Monopulmonar , Brônquios , Broncoscopia , Humanos , Intubação Intratraqueal , Pulmão